{"product_id":"accuris-smartdrop-nano-spectrophotometers","title":"Accuris SmartDrop Nano Spectrophotometers","description":"\u003carticle\u003e\n\u003ch2\u003eAccuris™ SmartDrop™ Nano Spectrophotometers\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUsed for Microvolume Analysis of DNA, RNA, and Proteins\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQuick and accurate results from a sample droplet\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTouch screen control panel, no PC or software required\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt-in printer and cuvette port for OD600 readings\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eXF model includes fluorometer for sensitive DNA\u003cbr\u003equantification\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cem\u003e\u003cstrong\u003eSmartDrop L\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\nIdeal for basic DNA-RNA-protein quantification and purity\n\u003c\/li\u003e\n\u003cli\u003eAffordable LED and silicon detector technology\u003c\/li\u003e\n\u003cli\u003eFixed 0.5mm path length, detect up to 2500ng-µl of dsDNA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSmartDrop L is the affordable choice for laboratories needing to determine nucleic acid and protein concentrations and purity of samples. The LED light source and silicon photocell sensor provide readings at 260 and 280nm. Samples from 1.0 to 2.0µl are loaded directly on the pedestal. Results are provided in about 5 seconds. The software automatically\u003cbr\u003ecalculates and displays 260-280 ratios.\u003c\/p\u003e\n\u003ch2\u003e\u003cem\u003e\u003cstrong\u003eSmartDrop X\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFull-spectrum absorbance scans from 200 to 800nm\u003c\/li\u003e\n\u003cli\u003eQuickly calculates and displays 260-280 and 260-230 ratios\u003c\/li\u003e\n\u003cli\u003eLong-life Xenon lamp with precision monochromator\u003c\/li\u003e\n\u003cli\u003eAuto-ranging path lengths of 0.2mm and 1.0mm\u003c\/li\u003e\n\u003cli\u003eDetect up to 4,500 ng-µl of dsDNA without dilution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA full spectrum UV-Vis spectrophotometer, SmartDrop X requires 0.5 to 2.0µl of sample. In addition to nucleic acid and protein calculations, the software has preset programs for BCA, Bradford and Lowry assays. A full spectrum analysis can be performed in about 6 seconds, aiding in the\u003cbr\u003eidentification of unknowns. Up to 5 specific points on the spectrum can be selected for colorimetric readings output. The long life Xenon lamp source requires no warmup and is paired with a highly sensitive CCD detector. To provide the most accurate results, the SmartDrop X utilizes 2 path lengths.\u003c\/p\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003cstrong\u003eSmartDrop XF\u003c\/strong\u003e\u003c\/em\u003e – Spectrophotometer + Fluorometer\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFull-spectrum absorbance scanning and calculations of\u003cbr\u003e260-280 and 260-230 ratios\u003c\/li\u003e\n\u003cli\u003eLong-life Xenon lamp with precision monochromator\u003c\/li\u003e\n\u003cli\u003eAuto-ranging path lengths of 0.05mm, 0.2mm and\u003cbr\u003e1.0mm\u003c\/li\u003e\n\u003cli\u003eDetect up to 15,000ng-µl of dsDNA without dilution\u003c\/li\u003e\n\u003cli\u003eIntegrated fluorometer for sensitive quantitation of low\u003cbr\u003econcentration nucleic acids\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis top-of-the-line spectrophotometer can perform not only UV-Vis readings in the range of 200-800nm but also fluorescence readings. Like the SmartDrop X, the SmartDrop XF features predefined programs for nucleic acids, proteins, and various colorimetric assays. The patented, motorized system gently stretches the sample column and allows for three different path lengths, providing accurate readings of samples from 0.5 to 2.0µl without dilution.\u003cbr\u003eThe integrated fluorometer yields more accurate, sensitive and selective quantitation of nucleic acids. The blue light channel (460nm) is useful for detection of dyes such as PicoGreen and RiboGreen as well as GFP and fluorescein. UV, green and red channel models are available upon\u003cbr\u003erequest.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.msesupplies.com\/products\/accuris-isopure-96-automated-purification-system-accessories-and-consumables\" title=\"Accuris IsoPure 96 Automated Purification System Accessories and Consumables\"\u003e\u003cstrong\u003ePurchase Accuris SmartDrop Accessories Through PSTG Supplies Here! \u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSmartDrop L (NS1000)\u003c\/td\u003e\n\u003ctd\u003eSmartDrop X (NS1010)\u003c\/td\u003e\n\u003ctd\u003eSmartDrop XF (NS1020)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7-inch touch screen\u003c\/td\u003e\n\u003ctd\u003e7-inch touch screen\u003c\/td\u003e\n\u003ctd\u003e7-inch touch screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum sample size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0µl – 2.0µl\u003c\/td\u003e\n\u003ctd\u003e0.5µl – 2.0µl\u003c\/td\u003e\n\u003ctd\u003e0.5µl – 2.0µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePath length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5mm\u003c\/td\u003e\n\u003ctd\u003e0.2mm, 1.0mm\u003c\/td\u003e\n\u003ctd\u003e0.05mm, 0.2mm, 1.0mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLight source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUV LED\u003c\/td\u003e\n\u003ctd\u003eXenon Flash Lamp\u003c\/td\u003e\n\u003ctd\u003eXenon Flash Lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUV Silicon Photocell\u003c\/td\u003e\n\u003ctd\u003e2048 Element Linear Silicon CCD Array\u003c\/td\u003e\n\u003ctd\u003e2048 Element Linear Silicon CCD Array\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e260, 280, \u0026amp; 600nm\u003c\/td\u003e\n\u003ctd\u003e200 – 800nm (1nm steps)\u003c\/td\u003e\n\u003ctd\u003e200 – 800nm (1nm steps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAbsorbance range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 – 50 A (10mm equivalent)\u003c\/td\u003e\n\u003ctd\u003e0.04 – 90 A (10mm equivalent)\u003c\/td\u003e\n\u003ctd\u003e0.04 – 300 A (10mm equivalent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAbsorbance precision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.005 A\u003c\/td\u003e\n\u003ctd\u003e0.003 A\u003c\/td\u003e\n\u003ctd\u003e0.003 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLower limit of detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003edsDNA: 10ng-µl; BSA: 0.1 mg-ml\u003c\/td\u003e\n\u003ctd\u003edsDNA: 2ng-µl; BSA: 0.1mg-ml\u003c\/td\u003e\n\u003ctd\u003edsDNA: 2ng-µl ; BSA: 0.1mg-ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUpper limit of detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003edsDNA: 2,500ng-µl; BSA: 75.0 mg-ml\u003c\/td\u003e\n\u003ctd\u003edsDNA: 4,500ng-µl; BSA: 135mg-ml\u003c\/td\u003e\n\u003ctd\u003edsDNA: 15,000ng-µl; BSA: 360mg-ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetection time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 6 seconds\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 seconds\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 6 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB for data export\u003c\/td\u003e\n\u003ctd\u003eUSB for data export\u003c\/td\u003e\n\u003ctd\u003eUSB for data export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC 24V, 2A\u003c\/td\u003e\n\u003ctd\u003eDC 24V, 2A\u003c\/td\u003e\n\u003ctd\u003eDC 24V, 2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25W\u003c\/td\u003e\n\u003ctd\u003e25W\u003c\/td\u003e\n\u003ctd\u003e25W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (WxDxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20.8 x 8.0 x 18.6 cm - 8.2 x 11.0 x 7.3 in.\u003c\/td\u003e\n\u003ctd\u003e20.8 x 8.0 x 18.6 cm - 8.2 x 11.0 x 7.3 in.\u003c\/td\u003e\n\u003ctd\u003e20.8 x 8.0 x 18.6 cm - 8.2 x 11.0 x 7.3 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.6 kg - 7.9 lbs\u003c\/td\u003e\n\u003ctd\u003e2.8 kg - 6.2 lbs\u003c\/td\u003e\n\u003ctd\u003e3.6 kg - 7.9 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e\u003cstrong\u003eCuvette OD600 detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAbsorbance range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 – 4.0 A\u003c\/td\u003e\n\u003ctd\u003e0.0 – 4.0 A\u003c\/td\u003e\n\u003ctd\u003e0.0 – 4.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAbsorbance stability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e[0,3) ≤ 0.5%, [3,4) ≤ 2%\u003c\/td\u003e\n\u003ctd\u003e[0,3) ≤ 0.5%, [3,4) ≤ 2%\u003c\/td\u003e\n\u003ctd\u003e[0,3) ≤ 0.5%, [3,4) ≤ 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAbsorbance repeatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e[0,3) ≤ 0.5%, [3,4) ≤ 2%\u003c\/td\u003e\n\u003ctd\u003e[0,3) ≤ 0.5%, [3,4) ≤ 2%\u003c\/td\u003e\n\u003ctd\u003e[0,3) ≤ 0.5%, [3,4) ≤ 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAbsorbance precision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e[0,2) ≤ 0.005 A, [2,3) ≤ 1%, [3,4) ≤ 2%\u003c\/td\u003e\n\u003ctd\u003e[0,2) ≤ 0.005 A, [2,3) ≤ 1%, [3,4) ≤ 2%\u003c\/td\u003e\n\u003ctd\u003e[0,2) ≤ 0.005 A, [2,3) ≤ 1%, [3,4) ≤ 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e\u003cstrong\u003eFluorescence detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExcitation-Emission\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN-A\u003c\/td\u003e\n\u003ctd\u003eN-A\u003c\/td\u003e\n\u003ctd\u003e460 ± 20nm - 525-570nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN-A\u003c\/td\u003e\n\u003ctd\u003eN-A\u003c\/td\u003e\n\u003ctd\u003edsDNA: 0.5pg-µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinearity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN-A\u003c\/td\u003e\n\u003ctd\u003eN-A\u003c\/td\u003e\n\u003ctd\u003eR² ≥ 0.995\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRepeatability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN-A\u003c\/td\u003e\n\u003ctd\u003eN-A\u003c\/td\u003e\n\u003ctd\u003e≤ 1.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN-A\u003c\/td\u003e\n\u003ctd\u003eN-A\u003c\/td\u003e\n\u003ctd\u003e≤ 1.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePSTG supplies is an authorized distributor of Accuris products and accessories. \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/article\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003edsDNA\u003c\/th\u003e\n\u003ctd\u003e10ng-µl; BSA: 0.1 mg-ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003edsDNA\u003c\/th\u003e\n\u003ctd\u003e2ng-µl; BSA: 0.1mg-ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003edsDNA\u003c\/th\u003e\n\u003ctd\u003e2ng-µl ; BSA: 0.1mg-ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003edsDNA\u003c\/th\u003e\n\u003ctd\u003e2,500ng-µl; BSA: 75.0 mg-ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003edsDNA\u003c\/th\u003e\n\u003ctd\u003e4,500ng-µl; BSA: 135mg-ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003edsDNA\u003c\/th\u003e\n\u003ctd\u003e15,000ng-µl; BSA: 360mg-ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003edsDNA\u003c\/th\u003e\n\u003ctd\u003e0.5pg-µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Accuris","offers":[{"title":"Default","offer_id":56357589877113,"sku":"7174474432570","price":15398600.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6977\/8041\/files\/NS1000L_large_55edcf52-7f75-42e2-9952-692d397e78de.jpg?v=1765770801","url":"https:\/\/www.nassventures-africa.com\/products\/accuris-smartdrop-nano-spectrophotometers","provider":"My Store","version":"1.0","type":"link"}