{"product_id":"atto-wsl-1565-kronos-ht-bioluminescence-measurement-system-for-living-cell-and-tissues","title":"ATTO WSL-1565 Kronos HT-Bioluminescence measurement system for living cell and tissues","description":"\u003carticle\u003e\n\n\u003ch2\u003eATTO WSL-1565 Kronos HT-Bioluminescence measurement system for living cell and tissues\u003c\/h2\u003e\n\n\u003ch2\u003e\u003cstrong\u003e\u003cstrong\u003eBuy ATTO products from PSTG Supplies at the best Value.\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\n\u003cp\u003eThe Kronos HT is performing to detect high sensitivity for dim and weak luminescence consecutively in culture samples such as cells and tissues in 24 well plates for a long time. 96 well plates and 35 mm dishes also applicable.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSample stage is in the incubation chamber in which temperature and CO2 gas concentration is controlled and humidity is kept \u0026gt;90%RH.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e24・96 wells micro plate applicable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLong-time detection available *1hour～30days\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 plates are measured by 2 PMTs (one PMT to one plate)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePlates are not moved, PMTs are moved to each well. \u0026gt; No shaking cells, so less damage to delicate cells and applicable to floating cells such as hematocytes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePMTs are cooled to 10℃ \u0026gt; The dark noise is lower.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt in filters for Multi-color luciferase assay\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003ePSTG Supplies is an authorized distributor of ATTO products.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\n\u003ctable data-show-header=\"true\" data-filter-position=\"right\" data-filter-placeholder=\"Search...\" data-filter-filters=\"[]\" data-filtering=\"true\" data-sorting=\"true\" data-use-parent-width=\"false\" data-filter-connectors=\"false\" data-filter-container=\"#filterBox\" data-useparentwidth=\"true\" data-paging-size=\"5\" data-filter-min=\"3\" data-cascade=\"true\" data-paging=\"false\" dir=\"auto\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eWSL-1565\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetector \u003c\/td\u003e\n\u003ctd\u003ePhotoMultiplier Tube (PMT) (10℃ cooling) x 2 units \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement \u003c\/td\u003e\n\u003ctd\u003ePhoton counting method \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement time \u003c\/td\u003e\n\u003ctd\u003e1 - 60s\/well, for 1 h - 30 days \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFormat \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e24 well clear bottom plate x 2 (standard)\u003c\/p\u003e\n\u003cp\u003e96 well clear bottom plate x 2 (optional)\u003c\/p\u003e\n\u003cp\u003e35 mm dish x 12 (optional) \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection plate \u003c\/td\u003e\n\u003ctd\u003e2 PMTs (one PMT to one plate) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nNumber of specimens \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e48 samples (24 well plate x 2) standard\u003c\/p\u003e\n\u003cp\u003e192 samples (96 well plate x 2) optional\u003c\/p\u003e\n\u003cp\u003e12 samples (35 mm dish x 12) optional \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncubation temperature control \u003c\/td\u003e\n\u003ctd\u003eRoom temperature +5°C~45°C (0.1°C steps) in a room temperature environment of 20~28°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCO₂ gas control \u003c\/td\u003e\n\u003ctd\u003e\nAdjust CO2 gas concentration with CO2 gas mixing unit  and introduce it into the cabinet (setting range: 1.0 - 20%)\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidification \u003c\/td\u003e\n\u003ctd\u003eSetting of water receiver in incubator and humidified 5% CO₂ gas flowing intermittently by humidifying out Maintaining \u0026gt; 90% RH \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMulti-color assay \u003c\/td\u003e\n\u003ctd\u003eMeasurement with automatically selected optical filter up to 2 colors \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePC requirements \u003c\/td\u003e\n\u003ctd\u003eOS: Windows 11, 64\/32 bit, Memory: 4GB HDD: more than 20 GB \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePC interface \u003c\/td\u003e\n\u003ctd\u003eUSB 2.0 x 1 port \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimension(mm)\u003c\/td\u003e\n\u003ctd\u003e650 (W) x 520 (D) x 340 (H) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (Kg)\u003c\/td\u003e\n\u003ctd\u003e40 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower \u003c\/td\u003e\n\u003ctd\u003eAC 100~240V 50\/60Hz 400W (Max) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eName\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003eCO2 gas inlet unit for Kronos HT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCO2 control\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003eAdjust the concentration in CO2 gas mixing unit and introduce it into the culture tank (setting range: 1.0 - 20%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eHumidification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003eIntroducing CO2  gas into the Kronos HT culture tank via a humidification unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (mm)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003eCO2 gas mixing unit: 121 (W) × 174 × 157 (H) \u003cbr\u003eHumidification unit: 170 (W) × 140 (D) × 115 (H) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight(Kg)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003eCO2 gas mixing unit: 1.6\u003cbr\u003eHumidification unit: 1.6 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003eCO2 gas mixing unit: AC100~240V, 50\/60Hz. 25W\u003cbr\u003eHumidification Unit: AC100~240V, 50\/60Hz, 30W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch3\u003eCitation and references(Kronos HT (WSL-1565))\u003c\/h3\u003e\n\n\u003col\u003e\n\u003cli\u003e\n\u003cp\u003e(Cytotoxicity) S. Wakuri, K. Yamakage, Y. Kazuki, K. Kazuki, M. Oshimura, S. Aburatani, M. Yasunaga and Y. Nakajima, Correlation between luminescence intensity and cytotoxicity in cell-based cytotoxicity assay using luciferase. Anal. Biochem., 522, 18-29 (2017)[PubMed]\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e(Oxidative stress) Y. Tabei, K. Murotomi, A. Umeno, M. Horie, Y. Tsujino, B. Masutani, Y. Yoshida, Y. Nakajima, Antioxidant properties of 5-hydroxy-4-phenyl-butenolide via activation of Nrf2\/ARE signaling pathway. Food Chem. Toxicol., 107(A), 129-137 (2017)[PubMed]\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e(Micro RNA) Y. Mie, Y. Hirano, K. Kowata, A. Nakamura, M. Yasunaga, Y. Nakajima and Y. Komatsu, Function control of anti-microRNA oligonucleotides using interstrand cross-linked duplexes, Mol. Ther. Nucleic Acids, 10, 64-74 (2018)[PubMed]\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e(Anti-inflammation) P. Saiki, Y. Kawano, Y. Nakajima, LJLD. Van Griensven and K. Miyazaki, Novel and stable dual-color IL-6 and IL-10 reporters derived from RAW 264.7 for anti-inflammation screening of natural products. Int. J. Mol. Sci., 20(18), 4620 (2019)[PubMed]\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e(Cytotoxicity) S. Iwado, S. Abe, M. Oshimura, Y. Kazuki and Y. Nakajima, Bioluminescence measurement of time-dependent dynamic changes of CYP-mediated cytotoxicity in CYP-expressing luminescent HepG2 cells. Int. J. Mol. Sci., 22(6), 2843 (2021)[PubMed]\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e(Clock gene) JS. Huh, S. Lee, DS. Kim, MS. Choi, H. Choi and KH. Lee, Antioxidative and circadian rhythm regulation effect of Quercus gilva extract. J. Korean Wood Sci. Technol., 50(5), 338-352 (2022)[Link]\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003c\/article\u003e","brand":"{\"name\":\"ATTO\"}","offers":[{"title":"650 (W) x 520 (D) x 340 (H)","offer_id":56355099050361,"sku":"7375302787130","price":320300.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6977\/8041\/files\/atto-wsl-1565-kronos-ht-bioluminescence-measurement-system-for-living-cell-and-tissues-default-title-atto-cell-culture-22603855560762.png?v=1765709109","url":"https:\/\/www.nassventures-africa.com\/products\/atto-wsl-1565-kronos-ht-bioluminescence-measurement-system-for-living-cell-and-tissues","provider":"My Store","version":"1.0","type":"link"}