{"product_id":"auto-positioning-system","title":"DRGEM GXR-SD Auto Positioning System Digital Radiography System","description":"\u003cp\u003e\u003cstrong\u003eDRGEM GXR-SD Auto Positioning System Digital Radiography System\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003eShort Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eDRGEM GXR-SD Auto Positioning System\u003c\/strong\u003e is a fully motorized digital radiography solution designed to improve workflow, positioning accuracy, image consistency, and patient safety. With synchronized movements, auto-tracking technology, advanced RADMAX imaging software, and flexible detector compatibility, it is well suited for modern radiology departments and diagnostic imaging facilities.\u003c\/p\u003e\n\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eDRGEM GXR-SD\u003c\/strong\u003e is built to streamline radiographic workflow through intelligent automation and precision control. The system combines an \u003cstrong\u003eautomatic tilting wall bucky stand\u003c\/strong\u003e, \u003cstrong\u003eautomatic ceiling-suspended tube stand\u003c\/strong\u003e, and \u003cstrong\u003eelevating patient table\u003c\/strong\u003e to deliver smooth, fast, and accurate positioning for a wide range of examinations.\u003c\/p\u003e\n\u003cp\u003eIts auto-positioning and synchronization functions help reduce setup time and operator effort, while the integrated \u003cstrong\u003eRADMAX workstation\u003c\/strong\u003e supports image preview, generator control, collimation control, worklist management, and positioning from an intuitive user interface. Advanced imaging tools such as \u003cstrong\u003ereal-time image adjustment\u003c\/strong\u003e, \u003cstrong\u003ebone suppression\u003c\/strong\u003e, \u003cstrong\u003escatter reduction\u003c\/strong\u003e, \u003cstrong\u003epatient movement detection\u003c\/strong\u003e, and \u003cstrong\u003evirtual AEC field display\u003c\/strong\u003e further enhance image quality and efficiency.\u003c\/p\u003e\n\u003cp\u003eThe system also incorporates important safety and dose management features including \u003cstrong\u003ecollision-prevention safety sensors\u003c\/strong\u003e, \u003cstrong\u003eemergency stop switches\u003c\/strong\u003e, \u003cstrong\u003eAEC\u003c\/strong\u003e, \u003cstrong\u003eDAP\u003c\/strong\u003e, \u003cstrong\u003eRDSR\u003c\/strong\u003e, and a \u003cstrong\u003ecarbon fiber tabletop\u003c\/strong\u003e for improved X-ray transmittance.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0935\/6977\/8041\/files\/Screenshot_2026-04-09_at_00.04.32.png?v=1775689527\" alt=\"\"\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"1964\" data-end=\"1979\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1980\" data-end=\"2576\"\u003e\n\u003cli data-section-id=\"1fwzmm8\" data-start=\"1980\" data-end=\"2024\"\u003eFully motorized digital radiography system\u003c\/li\u003e\n\u003cli data-section-id=\"1bqksps\" data-start=\"2025\" data-end=\"2052\"\u003eAuto-positioning workflow\u003c\/li\u003e\n\u003cli data-section-id=\"zs9c24\" data-start=\"2053\" data-end=\"2089\"\u003eAutomatic tilting wall bucky stand\u003c\/li\u003e\n\u003cli data-section-id=\"km4nfe\" data-start=\"2090\" data-end=\"2130\"\u003eAutomatic ceiling-suspended tube stand\u003c\/li\u003e\n\u003cli data-section-id=\"1q0p28a\" data-start=\"2131\" data-end=\"2156\"\u003eElevating patient table\u003c\/li\u003e\n\u003cli data-section-id=\"112m8md\" data-start=\"2157\" data-end=\"2192\"\u003eAuto rotating touchscreen console\u003c\/li\u003e\n\u003cli data-section-id=\"12yubr3\" data-start=\"2193\" data-end=\"2215\"\u003eTable bucky tracking\u003c\/li\u003e\n\u003cli data-section-id=\"yh559k\" data-start=\"2216\" data-end=\"2242\"\u003eVertical synchronization\u003c\/li\u003e\n\u003cli data-section-id=\"1c1683a\" data-start=\"2243\" data-end=\"2259\"\u003eAuto stitching\u003c\/li\u003e\n\u003cli data-section-id=\"1c6aewq\" data-start=\"2260\" data-end=\"2288\"\u003ePrecision movement control\u003c\/li\u003e\n\u003cli data-section-id=\"3pc9wr\" data-start=\"2289\" data-end=\"2308\"\u003ePositioning guide\u003c\/li\u003e\n\u003cli data-section-id=\"saykea\" data-start=\"2309\" data-end=\"2337\"\u003eReal-time image adjustment\u003c\/li\u003e\n\u003cli data-section-id=\"19cvh9\" data-start=\"2338\" data-end=\"2370\"\u003eAI-based diagnostic assistance\u003c\/li\u003e\n\u003cli data-section-id=\"uwsp07\" data-start=\"2371\" data-end=\"2389\"\u003eBone suppression\u003c\/li\u003e\n\u003cli data-section-id=\"1yrahnb\" data-start=\"2390\" data-end=\"2409\"\u003eScatter reduction\u003c\/li\u003e\n\u003cli data-section-id=\"r41hjr\" data-start=\"2410\" data-end=\"2438\"\u003ePatient movement detection\u003c\/li\u003e\n\u003cli data-section-id=\"k20t1o\" data-start=\"2439\" data-end=\"2458\"\u003eVirtual AEC field\u003c\/li\u003e\n\u003cli data-section-id=\"91oylu\" data-start=\"2459\" data-end=\"2493\"\u003ePatient dose management features\u003c\/li\u003e\n\u003cli data-section-id=\"1e8oewi\" data-start=\"2494\" data-end=\"2576\"\u003eEmergency stop switches and safety sensors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0935\/6977\/8041\/files\/Screenshot_2026-04-09_at_00.07.07.png?v=1775689708\" alt=\"\"\u003e\u003c\/p\u003e\n\u003ch2\u003eSystem Configuration\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWall Bucky Stand\u003c\/td\u003e\n\u003ctd\u003eWBS-TA Deluxe automatic tilting wall bucky stand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTube Stand\u003c\/td\u003e\n\u003ctd\u003eTS-CSP Deluxe automatic ceiling suspended tube stand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePatient Table\u003c\/td\u003e\n\u003ctd\u003ePBT-6 Deluxe elevating patient table\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Console\u003c\/td\u003e\n\u003ctd\u003eAuto rotating touch screen console\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTube Stand Touch Screen\u003c\/td\u003e\n\u003ctd\u003e15.6 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWall Bucky LCD\u003c\/td\u003e\n\u003ctd\u003e10.1 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWorkflow and Positioning Functions\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto Positioning\u003c\/td\u003e\n\u003ctd\u003eOne-touch chest radiography positioning at SID 180 cm and abdomen positioning at SID 100 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVertical Synchronization\u003c\/td\u003e\n\u003ctd\u003eTube follows wall bucky vertical movement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWall Bucky Centering\u003c\/td\u003e\n\u003ctd\u003eTube tracks wall bucky center and rotates to expose tilted bucky perpendicularly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTable Bucky Tracking\u003c\/td\u003e\n\u003ctd\u003eBucky follows tube movement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrecision Movement Control\u003c\/td\u003e\n\u003ctd\u003eControl tube stand position, tube angle, and wall bucky height from RADMAX panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto Stitching\u003c\/td\u003e\n\u003ctd\u003eSupports long-length imaging on wall bucky stand and patient table\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePositioning Guide\u003c\/td\u003e\n\u003ctd\u003eGraphical operator guidance for positioning and X-ray technique\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eImaging and Software Features\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRADMAX Workstation\u003c\/td\u003e\n\u003ctd\u003eIntegrated imaging and workflow control platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImage Preview\u003c\/td\u003e\n\u003ctd\u003eImmediate image preview on system console\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReal-time Image Adjustment\u003c\/td\u003e\n\u003ctd\u003eSupports image optimization after acquisition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e9 Preset Views\u003c\/td\u003e\n\u003ctd\u003eConsistent preset image display options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLive Streaming Camera\u003c\/td\u003e\n\u003ctd\u003eDisplays live patient positioning view on RADMAX and THU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePatient Movement Detection\u003c\/td\u003e\n\u003ctd\u003eDetects motion and alerts operator before exposure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVirtual AEC Field\u003c\/td\u003e\n\u003ctd\u003eVirtual display of AEC field area for accurate positioning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAI-Based Diagnostic Assistance\u003c\/td\u003e\n\u003ctd\u003eAssists radiographic interpretation workflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBone Suppression\u003c\/td\u003e\n\u003ctd\u003eAI-based bone suppression for digital chest radiography\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScatter Reduction\u003c\/td\u003e\n\u003ctd\u003eSoftware-generated grid effect to reduce scatter without physical grid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eDetector Compatibility\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetector Sizes\u003c\/td\u003e\n\u003ctd\u003e10 x 12, 14 x 17, 17 x 17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScintillator\u003c\/td\u003e\n\u003ctd\u003eCsI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetector Types\u003c\/td\u003e\n\u003ctd\u003eFixed, Wireless, Wired portable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003ePatient Safety and Dose Management\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Sensors\u003c\/td\u003e\n\u003ctd\u003eHelps prevent collisions during system movement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmergency Stop Switches\u003c\/td\u003e\n\u003ctd\u003eLocated at wall bucky stand, tube stand, patient table, and control room\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAEC\u003c\/td\u003e\n\u003ctd\u003eAutomatic Exposure Control for limiting patient dose\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDAP\u003c\/td\u003e\n\u003ctd\u003eDose Area Product measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRDSR\u003c\/td\u003e\n\u003ctd\u003eRadiation Dose Structured Reports for DICOM standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Fiber Tabletop\u003c\/td\u003e\n\u003ctd\u003eSuperior X-ray transmittance with significantly reduced X-ray absorption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGenerator Options\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003ePower Rating\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGXR-52\u003c\/td\u003e\n\u003ctd\u003e52 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGXR-68\u003c\/td\u003e\n\u003ctd\u003e68 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGXR-82\u003c\/td\u003e\n\u003ctd\u003e82 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGenerator Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth align=\"right\"\u003eGXR-52\u003c\/th\u003e\n\u003cth align=\"right\"\u003eGXR-68\u003c\/th\u003e\n\u003cth align=\"right\"\u003eGXR-82\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Rating\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e52 kW\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e68 kW\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e82 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ekV Range\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e40 to 150 kV\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e40 to 150 kV\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e40 to 150 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emA Range\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e10 to 640 mA\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e10 to 800 mA\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e10 to 1,000 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimer Range\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e0.001 to 10 sec\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e0.001 to 10 sec\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e0.001 to 10 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emAs Range\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e0.1 to 500 mAs\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e0.1 to 500 mAs\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e0.1 to 500 mAs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional mAs\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eUp to 1,000 mAs\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eUp to 1,000 mAs\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eUp to 1,000 mAs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Power\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e380\/400\/480 VAC, 3-phase ±10%\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e380\/400\/480 VAC, 3-phase ±10%\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e380\/400\/480 VAC, 3-phase ±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRotor Supply\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eDual Speed\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eDual Speed\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eDual Speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003ePerformance Data\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eReproducibility\u003c\/td\u003e\n\u003ctd\u003eCoefficient of Variation: kV \u0026lt; 0.005, Time \u0026lt; 0.005, mAs \u0026lt; 0.01, mR \u0026lt; 0.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003ekV \u0026lt; ±(1% + 1kV), mA \u0026lt; ±(3% + 1mA), Time \u0026lt; ±(1% + 0.5ms), mAs \u0026lt; ±(3% + 0.1mAs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003eCoefficient of Linearity \u0026lt; 0.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e","brand":"DRGEM","offers":[{"title":"Default Title","offer_id":56997900845433,"sku":null,"price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6977\/8041\/files\/w4yh7wij.png?v=1775679952","url":"https:\/\/www.nassventures-africa.com\/products\/auto-positioning-system","provider":"My Store","version":"1.0","type":"link"}