{"product_id":"binder-mkt-115-climate-chamber-in-incubators-drying-cabinets","title":"BINDER MKT 115 climate chamber in Incubators, Drying Cabinets","description":"\u003carticle\u003e\n\n\u003ch2\u003eBINDER MKT 115 dynamic climate chamber\u003c\/h2\u003e\n\n\u003cp\u003eThe BINDER MKT 115 dynamic climate chamber is a versatile environmental simulation chamber for the precise control of rapid temperature changes in research, development and quality control. Thanks to its wide temperature range of -70 °C to +180 °C and state-of-the-art control technology, the system offers ideal conditions for demanding cycle tests on materials, components and products. Compared to comparable solutions, this model impresses with its homogeneous climate conditions thanks to APT.line preheating chamber technology, intuitive operation via touchscreen controller and an extended low-temperature spectrum.\u003c\/p\u003e\n\n\u003cp\u003ePrecision and reliability for demanding test procedures\u003c\/p\u003e\n\n\u003cp\u003eThe APT.line preheating chamber technology ensures constant and uniform temperature distribution by preheating the supplied air via a preheating chamber and then directing it into the interior in a targeted manner. This ensures that even the most sensitive samples are homogeneously and reproducibly conditioned at all times. An integrated fault diagnosis system ensures reliable monitoring of the working chamber. With a large, heated viewing window and well-lit LED interior lighting, experiments can be conveniently observed without having to open the door.\u003c\/p\u003e\n\n\u003cp\u003eThe touchscreen controller offers extensive options for time segment and real-time programming. Different temperature profiles, ramp functions and holding times can be freely defined. The internal data logger continuously records measured values and allows them to be read out in an open format via a USB interface. Programmable condensation protection plays a key role in protecting the samples from condensation and enables reliable short and long-term tests.\u003c\/p\u003e\n\n\u003ch3\u003eImportant technical key data at a glance\u003c\/h3\u003e\n\n\u003cp\u003e- Temperature range: -70 °C to +180 °C\u003cbr\u003e\n- Average heating speed (IEC 60068-3-5): 5.3 K\/min\u003cbr\u003e\n- Average cooling rate (IEC 60068-3-5): 4.2 K\/min\u003cbr\u003e\n- R-452A and R-23 as refrigerant (CFC-free)\u003cbr\u003e\n- Phase supply: 3~\/N\/PE (400 V) or 3~ (480 V)\u003cbr\u003e\n- Interior volume: 115 litres\u003cbr\u003e\n- Permissible total load: 60 kg\u003cbr\u003e\n- Door heating and heated viewing window\u003c\/p\u003e\n\n\u003cp\u003eIn addition, all components are carefully designed for durability and reliability. The high-quality cascade compression refrigeration unit ensures rapid cooling phases: Starting at 180 °C, the interior can be cooled down to -70 °C in just 110 minutes. With a temperature deviation of just ±0.1 to ±0.6 K over time, the appliance fulfils even the strictest accuracy requirements.\u003c\/p\u003e\n\n\u003cp\u003eThe chassis has a robust design and is fitted with castors, making it easy to move around the laboratory or production environment. Two of these castors are equipped with locking brakes so that the cabinet can be securely fixed in place if required. A class 2 temperature limiter (DIN 12880) is integrated for a high level of work safety, which triggers audible and visual alarms when critical limit values are reached.Certifications and standards\u003c\/p\u003e\n\n\u003cp\u003eThis mobile climate chamber complies with DIN 12880, which confirms compliance with important safety and quality standards. The combination of fault-diagnostic electronics, accurate sensors and reliable safety systems means that the appliance is highly trusted in laboratories and industrial quality assurance or research departments.\u003c\/p\u003e\n\n\u003cp\u003eApplication examples\u003c\/p\u003e\n\n\u003col\u003e\n\u003cli\u003eMaterial testing: Plastics, metals or composite materials can be tested under defined temperature cycles to precisely determine material ageing and resistance.  \u003c\/li\u003e\n\u003cli\u003eElectronic components: Printed circuit boards, sensors and end devices can be tested for functionality and failure potential under high temperature cycles.  \u003c\/li\u003e\n\u003cli\u003ePharmaceutical stability tests: medicines and active ingredients are exposed to cyclical temperature conditions to evaluate shelf life and efficacy.  \u003c\/li\u003e\n\u003cli\u003eVehicle components: Drive elements, plastic parts in the engine compartment or interior materials are tested for durability under rapid temperature changes.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\n\u003ch3\u003eHow exactly can the temperature be programmed?\u003c\/h3\u003e\n\n\u003cp\u003eThe intuitive touchscreen controller can be used to create various temperature sections, ramp profiles and hold phases, including a real-time clock. Fine adjustments are possible in very small steps, which is particularly advantageous for sensitive samples.\u003c\/p\u003e\n\n\u003cp\u003eCan condensation form on the samples?\u003c\/p\u003e\n\n\u003cp\u003eThe integrated, programmable condensation protection and the even air distribution in the APT.line preheating chamber minimise the formation of condensation. The humidity can also be monitored and controlled for certain test series.\u003c\/p\u003e\n\n\u003cp\u003eHow is the data storage organised?\u003c\/p\u003e\n\n\u003cp\u003eThe device has an internal data logger. All measured values can be read out regularly and transferred to a USB stick in open format to ensure complete documentation.\u003c\/p\u003e\n\n\u003ch3\u003eWhat happens in the event of a fault\u003c\/h3\u003e\n\n\u003cp\u003eA fault diagnosis system permanently monitors all operating parameters and signals deviations via visual and acoustic alarms. In addition, staff can use potential-free switching contacts for external signalling or safety systems.\u003c\/p\u003e\n\n\u003cp\u003eAre different power supplies possible?\u003c\/p\u003e\n\n\u003cp\u003eYes, versions are available for 400 V (three-phase alternating current, 50 Hz) or 480 V (three-phase alternating current, 60 Hz). Depending on the model, a voltage and frequency converter ensures flexible application options, for example in international laboratories.\u003c\/p\u003e\n\n\u003ch2\u003eConclusion\u003c\/h2\u003e\n\n\u003cp\u003eThis modern climatic test chamber can be used to perform the most demanding tests in terms of accuracy, speed and reliability. The sophisticated APT.line preheating chamber technology, the flexibly programmable profiles and the reliable condensation protection make highly complex applications in research, development and quality control possible. In addition, the integrated safety system and the high-quality cascade compression chiller ensure consistently reliable results. The device therefore fulfils high requirements in terms of precision and user-friendliness.\u003c\/p\u003e\n\n\u003ctable\u003e\u003ctbody\u003e\n                                                            \u003ctr\u003e\n                            \u003ctd\u003e\n                                Load max.:\n\n                            \u003c\/td\u003e\n                             \u003ctd\u003e\n51 - 100 kg\n                            \u003c\/td\u003e\n                        \u003c\/tr\u003e\n                                            \u003ctr\u003e\n                            \u003ctd\u003e\n                                Width outside (incubators,...):\n\n                            \u003c\/td\u003e\n                             \u003ctd\u003e\n980 mm\n                            \u003c\/td\u003e\n                        \u003c\/tr\u003e\n                                            \u003ctr\u003e\n                            \u003ctd\u003e\n                                Width inside (incubators,...):\n\n                            \u003c\/td\u003e\n                             \u003ctd\u003e\n600 mm\n                            \u003c\/td\u003e\n                        \u003c\/tr\u003e\n                                            \u003ctr\u003e\n                            \u003ctd\u003e\n                                Maximum temperature (heat):\n\n                            \u003c\/td\u003e\n                             \u003ctd\u003e\n+ 180 °C\n                            \u003c\/td\u003e\n                        \u003c\/tr\u003e\n                                            \u003ctr\u003e\n                            \u003ctd\u003e\n                                Height outside (incubators,...):\n\n                            \u003c\/td\u003e\n                             \u003ctd\u003e\n1725 mm\n                            \u003c\/td\u003e\n                        \u003c\/tr\u003e\n                                            \u003ctr\u003e\n                            \u003ctd\u003e\n                                Height inside (incubators,...):\n\n                            \u003c\/td\u003e\n                             \u003ctd\u003e\n480 mm\n                            \u003c\/td\u003e\n                        \u003c\/tr\u003e\n                                            \u003ctr\u003e\n                            \u003ctd\u003e\n                                Interior volume:\n\n                            \u003c\/td\u003e\n                             \u003ctd\u003e\n101 - 200 l\n                            \u003c\/td\u003e\n                        \u003c\/tr\u003e\n                                            \u003ctr\u003e\n                            \u003ctd\u003e\n                                Maximum power:\n\n                            \u003c\/td\u003e\n                             \u003ctd\u003e\n5,5 kW\n                            \u003c\/td\u003e\n                        \u003c\/tr\u003e\n                                            \u003ctr\u003e\n                            \u003ctd\u003e\n                                Cabinet type:\n\n                            \u003c\/td\u003e\n                             \u003ctd\u003e\nclimate chamberenvironmental simulation chamberdynamic climate chamber\n                            \u003c\/td\u003e\n                        \u003c\/tr\u003e\n                                            \u003ctr\u003e\n                            \u003ctd\u003e\n                                Safety standard:\n\n                            \u003c\/td\u003e\n                             \u003ctd\u003e\nDIN 12880IEC 60068-3-5\n                            \u003c\/td\u003e\n                        \u003c\/tr\u003e\n                                            \u003ctr\u003e\n                            \u003ctd\u003e\n                                Depth outside (incubators,...):\n\n                            \u003c\/td\u003e\n                             \u003ctd\u003e\n865 mm\n                            \u003c\/td\u003e\n                        \u003c\/tr\u003e\n                                            \u003ctr\u003e\n                            \u003ctd\u003e\n                                Depth inside (incubators,...):\n\n                            \u003c\/td\u003e\n                             \u003ctd\u003e\n400 mm\n                            \u003c\/td\u003e\n                        \u003c\/tr\u003e\n                                            \u003ctr\u003e\n                            \u003ctd\u003e\n                                Lowest temperature (cooling):\n\n                            \u003c\/td\u003e\n                             \u003ctd\u003e\n- 70 °C\n                            \u003c\/td\u003e\n                        \u003c\/tr\u003e\n                    \n                \n                                    \u003ctr\u003e\n                        \u003ctd\u003eShipping weight: \u003c\/td\u003e\n                        \u003ctd\u003e305,00 Kg\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                \n                                    \u003ctr\u003e\n                        \u003ctd\u003eProduct weight: \u003c\/td\u003e\n                        \u003ctd\u003e305,00 Kg\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                \n                \n                                    \u003ctr\u003e\n                        \u003ctd\u003eDimensions: \u003c\/td\u003e\n                        \u003ctd\u003e ×  ×  cm\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                \n                                    \n                            \u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003c\/article\u003e","brand":"Binder","offers":[{"title":"Default Title","offer_id":56331852906873,"sku":"BIND_6148","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6977\/8041\/files\/en-laboratory-incubators-drying-cabinets-binder-mkt-115-climate-chamber.jpg?v=1765206006","url":"https:\/\/www.nassventures-africa.com\/products\/binder-mkt-115-climate-chamber-in-incubators-drying-cabinets","provider":"My Store","version":"1.0","type":"link"}