{"product_id":"comen-agss-anaesthetic-gas-scavenging-system","title":"COMEN AGSS-H and AGSS-L Anaesthetic Gas Scavenging System","description":"\u003cstyle\u003e\n#nv-comen-agss, #nv-comen-agss * {box-sizing:border-box !important;}\n#nv-comen-agss {display:block !important;width:100% !important;max-width:1000px !important;margin:0 auto !important;float:none !important;clear:both !important;position:static !important;color:#263341;font-family:Arial,Helvetica,sans-serif;line-height:1.7;overflow-wrap:anywhere;}\n#nv-comen-agss section {display:block !important;width:100% !important;max-width:100% !important;margin:0 auto 28px !important;float:none !important;clear:both !important;position:static !important;}\n#nv-comen-agss h2 {font-size:24px;line-height:1.35;color:#173e54;margin:0 0 14px;text-align:left;}\n#nv-comen-agss h3 {font-size:18px;line-height:1.45;color:#173e54;margin:0 0 9px;text-align:left;}\n#nv-comen-agss p {margin:0 0 14px;text-align:left;}\n#nv-comen-agss .nv-intro {padding:24px;background:#f1f6f8;border:1px solid #dce5e9;border-radius:8px;}\n#nv-comen-agss .nv-grid {display:grid !important;grid-template-columns:repeat(2,minmax(0,1fr)) !important;gap:16px !important;width:100% !important;max-width:100% !important;margin:0 auto !important;float:none !important;clear:both !important;position:static !important;}\n#nv-comen-agss .nv-card {display:block !important;min-width:0 !important;width:100% !important;margin:0 !important;padding:20px;background:#fff;border:1px solid #dde3e8;border-radius:7px;float:none !important;position:static !important;}\n#nv-comen-agss .nv-card p:last-child {margin-bottom:0;}\n#nv-comen-agss .nv-table-wrap {display:block !important;width:100% !important;max-width:100% !important;margin:0 auto !important;float:none !important;clear:both !important;overflow-x:auto !important;position:static !important;}\n#nv-comen-agss table {display:table !important;width:100% !important;max-width:100% !important;margin:0 auto !important;float:none !important;clear:both !important;border-collapse:collapse !important;table-layout:fixed !important;position:static !important;}\n#nv-comen-agss th,#nv-comen-agss td {padding:13px 15px;border:1px solid #d9dfe4;vertical-align:top;white-space:normal !important;overflow-wrap:anywhere;}\n#nv-comen-agss th {background:#f0f2f4;text-align:left;font-weight:600;}\n#nv-comen-agss td:first-child {width:35%;text-align:left;}\n#nv-comen-agss td:nth-child(2) {text-align:left;}\n#nv-comen-agss ul {margin:0 0 16px;padding-left:22px;text-align:left;}\n#nv-comen-agss li {margin:0 0 7px;}\n#nv-comen-agss .nv-note {padding:20px;background:#faf8f2;border:1px solid #e3dbbf;border-radius:7px;}\n#nv-comen-agss .nv-contact {padding:24px;background:#edf4f7;border:1px solid #d9e5eb;border-radius:8px;}\n@media(max-width:640px){#nv-comen-agss .nv-grid {grid-template-columns:minmax(0,1fr) !important;}#nv-comen-agss h2 {font-size:21px;}#nv-comen-agss .nv-intro,#nv-comen-agss .nv-contact,#nv-comen-agss .nv-note {padding:18px;}#nv-comen-agss th,#nv-comen-agss td {padding:10px;font-size:14px;}}\n\u003c\/style\u003e\u003cdiv id=\"nv-comen-agss\" style=\"width:100%;max-width:1000px;margin:0 auto;float:none;clear:both;box-sizing:border-box;\"\u003e\n\u003csection class=\"nv-intro\"\u003e\u003ch2\u003eCOMEN AGSS-H and AGSS-L Anaesthetic Gas Scavenging System\u003c\/h2\u003e\n\u003cp\u003eCOMEN AGSS-H and AGSS-L anaesthetic gas scavenging systems for compatible hospital exhaust ducts, with model selection based on the stated exhaust-pipe flow rate.\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eProduct introduction\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eCOMEN AGSS-H and AGSS-L\u003c\/strong\u003e are anaesthetic gas scavenging systems designed to work with hospital anaesthetic gas exhaust pipes. Select the model according to the stated exhaust-pipe flow rate and confirm the duct arrangement and anaesthesia-machine connection before installation.\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\n\u003cdiv class=\"nv-grid\"\u003e\n\u003cdiv class=\"nv-card\"\u003e\n\u003ch3\u003eTwo flow-based models\u003c\/h3\u003e\n\u003cp\u003eAGSS-H is specified for exhaust-pipe flow rates above 75 L\/min. AGSS-L is specified for rates below 50 L\/min.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"nv-card\"\u003e\n\u003ch3\u003eDuct compatibility\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer lists jet AGS ducts, negative-pressure AGS ducts and negative-pressure exhaust ducts.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"nv-card\"\u003e\n\u003ch3\u003ePhysical scavenging\u003c\/h3\u003e\n\u003cp\u003eThe source describes physical gas absorption without a separate gas supply, power supply or chemical consumables.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"nv-card\"\u003e\n\u003ch3\u003eMachine connection options\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer describes connection solutions for major anaesthesia-machine brands. Exact model and connector compatibility require confirmation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eOperating principle and waste-gas collection\u003c\/h2\u003e\n\u003cp\u003eWaste anaesthetic gas is described as overflow emitted by an anaesthesia machine at the end of expiration. It is discharged intermittently and includes exhaled gas and driving gas. The source identifies N2O, sevoflurane and isoflurane among gases that may be present, and notes waste-gas discharge from semi-closed breathing circuits.\u003c\/p\u003e\n\u003cp\u003eCOMEN AGSS works with hospital exhaust pipes to remove anaesthetic waste gases. The manufacturer states that its design helps reduce breathing-circuit ventilation abnormalities associated with negative pressure in exhaust ducts.\u003c\/p\u003e\n\u003cp\u003eThe source describes physical gas absorption without a separate gas or power supply and without chemical consumables. A compatible hospital exhaust arrangement is still required.\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eModel comparison\u003c\/h2\u003e\n\u003cdiv class=\"nv-table-wrap\" style=\"width:100%;max-width:100%;margin:0 auto;float:none;clear:both;overflow-x:auto;box-sizing:border-box;\"\u003e\u003ctable style=\"width:100%;max-width:100%;margin:0 auto;float:none;clear:both;box-sizing:border-box;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eAGSS-H\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eAGSS-L\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eExhaust-pipe flow rate\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u0026gt; 75 L\/min\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u0026lt; 50 L\/min\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating method\u003c\/td\u003e\n\u003ctd\u003ePhysical gas absorption\u003c\/td\u003e\n\u003ctd\u003ePhysical gas absorption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeparate gas or power supply\u003c\/td\u003e\n\u003ctd\u003eNot required, according to the supplied source\u003c\/td\u003e\n\u003ctd\u003eNot required, according to the supplied source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical consumables\u003c\/td\u003e\n\u003ctd\u003eNot required, according to the supplied source\u003c\/td\u003e\n\u003ctd\u003eNot required, according to the supplied source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation interface\u003c\/td\u003e\n\u003ctd\u003eCompatible hospital anaesthetic gas exhaust pipes\u003c\/td\u003e\n\u003ctd\u003eCompatible hospital anaesthetic gas exhaust pipes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eThe source does not specify a suitable model for exhaust-pipe flow rates from 50 to 75 L\/min, including the stated boundary values. Confirm model selection for that range with the manufacturer.\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eCompatible ducts and anaesthesia machines\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eJet AGS ducts.\u003c\/li\u003e\n\u003cli\u003eNegative-pressure AGS ducts.\u003c\/li\u003e\n\u003cli\u003eNegative-pressure ducts for high- and low-velocity exhaust arrangements.\u003c\/li\u003e\n\u003cli\u003eManufacturer-described connection solutions for major anaesthesia-machine brands.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe source claims suitability for almost all anaesthesia machines. Confirm the specific machine, connector and exhaust-system requirements before treating a configuration as compatible.\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eCommissioning and applications\u003c\/h2\u003e\n\u003cp\u003eThe manufacturer describes a simple commissioning process and stable exhaust discharge. Installation is intended to work with compatible hospital anaesthetic gas exhaust pipes serving anaesthesia equipment.\u003c\/p\u003e\n\u003cp\u003eContact Nass Ventures to confirm the exhaust-pipe flow rate, duct type, machine connection and commissioning requirements for the intended installation.\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003cdiv class=\"nv-table-wrap\" style=\"width:100%;max-width:100%;margin:0 auto;float:none;clear:both;overflow-x:auto;box-sizing:border-box;\"\u003e\u003ctable style=\"width:100%;max-width:100%;margin:0 auto;float:none;clear:both;box-sizing:border-box;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSupplied information\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eCOMEN (Shenzhen Comen Medical Instruments Co., Ltd.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eAnaesthetic gas scavenging system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModels\u003c\/td\u003e\n\u003ctd\u003eAGSS-H and AGSS-L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAGSS-H exhaust-pipe flow\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 75 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAGSS-L exhaust-pipe flow\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 50 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating method\u003c\/td\u003e\n\u003ctd\u003ePhysical gas absorption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeparate gas supply\u003c\/td\u003e\n\u003ctd\u003eNot required, according to the supplied source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeparate power supply\u003c\/td\u003e\n\u003ctd\u003eNot required, according to the supplied source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical consumables\u003c\/td\u003e\n\u003ctd\u003eNot required, according to the supplied source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExhaust interface\u003c\/td\u003e\n\u003ctd\u003eHospital anaesthetic gas exhaust pipes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuct types listed\u003c\/td\u003e\n\u003ctd\u003eJet AGS, negative-pressure AGS and negative-pressure exhaust ducts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnaesthesia-machine connections\u003c\/td\u003e\n\u003ctd\u003eManufacturer-described solutions for major brands; specific compatibility to be confirmed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection class=\"nv-note\"\u003e\u003ch2\u003eManufacturer information requiring verification\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm model selection for flow rates of 50–75 L\/min, including exactly 50 L\/min and 75 L\/min. The source supplies no selection rule for these values.\u003c\/li\u003e\n\u003cli\u003eConfirm the installed duct type, available exhaust flow, operating negative pressure and machine connection requirements.\u003c\/li\u003e\n\u003cli\u003eConfirm the scope of the statement that no gas or power supply is required, including the hospital exhaust infrastructure needed for operation.\u003c\/li\u003e\n\u003cli\u003eConfirm the exact anaesthesia-machine models and connectors supported.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe supplied page attributes mutagenicity, carcinogenicity, organ toxicity, fertility effects and psychological effects to inhaled anaesthetics, citing the Chinese Society of Anesthesiology’s “Guidance on the Management of Anesthetic Gas Leaks”. These broad statements are reproduced here as source claims requiring verification against the exact guidance and agent-specific evidence before publication. They are not presented as established effects of every anaesthetic agent.\u003c\/p\u003e\n\u003cp\u003eDimensions, weight, construction materials, supplied connectors and numerical exhaust performance are not specified in the source.\u003c\/p\u003e\u003c\/section\u003e\u003csection class=\"nv-contact\"\u003e\u003ch2\u003eCOMEN AGSS-H and AGSS-L Anaesthetic Gas Scavenging System from Nass Ventures\u003c\/h2\u003e\n\u003cp\u003eContact Nass Ventures for pricing, configuration, compatible accessories, installation requirements and technical support.\u003c\/p\u003e\u003c\/section\u003e\n\u003c\/div\u003e","brand":"COMEN","offers":[{"title":"AGSS-H","offer_id":64757570470265,"sku":"AGSS-H","price":0.0,"currency_code":"NGN","in_stock":true},{"title":"AGSS-L","offer_id":64757570503033,"sku":"AGSS-L","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6977\/8041\/files\/0ecde9bd-2e53-491b-8401-3c589f65e0d6.png?v=1790876371","url":"https:\/\/www.nassventures-africa.com\/products\/comen-agss-anaesthetic-gas-scavenging-system","provider":"My Store","version":"1.0","type":"link"}