{"product_id":"comen-ax900-anaesthesia-workstation","title":"COMEN AX-900 Anaesthesia Workstation","description":"\u003cstyle\u003e\n#nv-comen-ax900, #nv-comen-ax900 * {box-sizing:border-box !important;}\n#nv-comen-ax900 {display:block !important;width:100% !important;max-width:1000px !important;margin:0 auto !important;float:none !important;clear:both !important;position:static !important;color:#263341;font-family:Arial,Helvetica,sans-serif;line-height:1.7;overflow-wrap:anywhere;}\n#nv-comen-ax900 section {display:block !important;width:100% !important;max-width:100% !important;margin:0 auto 28px !important;float:none !important;clear:both !important;position:static !important;}\n#nv-comen-ax900 h2 {font-size:24px;line-height:1.35;color:#173e54;margin:0 0 14px;text-align:left;}\n#nv-comen-ax900 h3 {font-size:18px;line-height:1.45;color:#173e54;margin:0 0 9px;text-align:left;}\n#nv-comen-ax900 p {margin:0 0 14px;text-align:left;}\n#nv-comen-ax900 .nv-intro {padding:24px;background:#f1f6f8;border:1px solid #dce5e9;border-radius:8px;}\n#nv-comen-ax900 .nv-grid {display:grid !important;grid-template-columns:repeat(2,minmax(0,1fr)) !important;gap:16px !important;width:100% !important;max-width:100% !important;margin:0 auto !important;float:none !important;clear:both !important;position:static !important;}\n#nv-comen-ax900 .nv-card {display:block !important;min-width:0 !important;width:100% !important;margin:0 !important;padding:20px;background:#fff;border:1px solid #dde3e8;border-radius:7px;float:none !important;position:static !important;}\n#nv-comen-ax900 .nv-card p:last-child {margin-bottom:0;}\n#nv-comen-ax900 .nv-table-wrap {display:block !important;width:100% !important;max-width:100% !important;margin:0 auto !important;float:none !important;clear:both !important;overflow-x:auto !important;position:static !important;}\n#nv-comen-ax900 table {display:table !important;width:100% !important;max-width:100% !important;margin:0 auto !important;float:none !important;clear:both !important;border-collapse:collapse !important;table-layout:fixed !important;position:static !important;}\n#nv-comen-ax900 th,#nv-comen-ax900 td {padding:13px 15px;border:1px solid #d9dfe4;vertical-align:top;white-space:normal !important;overflow-wrap:anywhere;}\n#nv-comen-ax900 th {background:#f0f2f4;text-align:left;font-weight:600;}\n#nv-comen-ax900 td:first-child {width:35%;text-align:left;}\n#nv-comen-ax900 td:nth-child(2) {text-align:left;}\n#nv-comen-ax900 ul {margin:0 0 16px;padding-left:22px;text-align:left;}\n#nv-comen-ax900 li {margin:0 0 7px;}\n#nv-comen-ax900 .nv-note {padding:20px;background:#faf8f2;border:1px solid #e3dbbf;border-radius:7px;}\n#nv-comen-ax900 .nv-contact {padding:24px;background:#edf4f7;border:1px solid #d9e5eb;border-radius:8px;}\n@media(max-width:640px){#nv-comen-ax900 .nv-grid {grid-template-columns:minmax(0,1fr) !important;}#nv-comen-ax900 h2 {font-size:21px;}#nv-comen-ax900 .nv-intro,#nv-comen-ax900 .nv-contact,#nv-comen-ax900 .nv-note {padding:18px;}#nv-comen-ax900 th,#nv-comen-ax900 td {padding:10px;font-size:14px;}}\n\u003c\/style\u003e\u003cdiv id=\"nv-comen-ax900\" style=\"width:100%;max-width:1000px;margin:0 auto;float:none;clear:both;box-sizing:border-box;\"\u003e\n\u003csection class=\"nv-intro\"\u003e\u003ch2\u003eCOMEN AX-900 Anaesthesia Workstation\u003c\/h2\u003e\n\u003cp\u003eCOMEN AX-900 anaesthesia workstation with ascending bellows, electronic fresh-gas control, nine ventilation modes and an independent 8-inch flow-control touchscreen.\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eProduct introduction\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eCOMEN AX-900\u003c\/strong\u003e integrates an anaesthesia ventilator, respiratory monitoring functions and electronic fresh-gas control in a surgical workstation. Pneumatic components work with electronic and fluid control to support ventilation, respiratory parameter adjustment and monitoring throughout perioperative use.\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\n\u003cdiv class=\"nv-grid\"\u003e\n\u003cdiv class=\"nv-card\"\u003e\n\u003ch3\u003ePneumatic drive and electronic control\u003c\/h3\u003e\n\u003cp\u003eAscending bellows and a compact circuit support ventilation delivery and triggering during SIMV and PSV.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"nv-card\"\u003e\n\u003ch3\u003ePerioperative ventilation\u003c\/h3\u003e\n\u003cp\u003eFour control modes, three SIMV modes and two pressure support modes are listed for different perioperative stages.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"nv-card\"\u003e\n\u003ch3\u003eClosed-loop fresh-gas control\u003c\/h3\u003e\n\u003cp\u003eDirect oxygen-concentration setting with automatic adjustment of the oxygen-to-balance-gas ratio.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"nv-card\"\u003e\n\u003ch3\u003eDedicated flow-control display\u003c\/h3\u003e\n\u003cp\u003eAn independent 8-inch LED touchscreen provides a separate fresh-gas operating area and flow information.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eVentilation technology and breathing circuit\u003c\/h2\u003e\n\u003cp\u003eAscending bellows combine pneumatic drive with electronic control. The manufacturer describes a compact breathing circuit and a smaller loop cavity, with stable ventilation and responsive triggering during SIMV and PSV. It also states a higher compression capacity, without specifying a value or comparison basis.\u003c\/p\u003e\n\u003cp\u003ePEEP supports clinician-directed lung protection and recruitment manoeuvres. The supplied figures are \u003cstrong\u003e7% ventilation accuracy\u003c\/strong\u003e and \u003cstrong\u003e65 ml\/min leakage\u003c\/strong\u003e. These are reproduced as supplied, with no assumed ± tolerance or additional test conditions.\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003ePerioperative ventilation modes\u003c\/h2\u003e\n\u003cdiv class=\"nv-table-wrap\" style=\"width:100%;max-width:100%;margin:0 auto;float:none;clear:both;overflow-x:auto;box-sizing:border-box;\"\u003e\u003ctable style=\"width:100%;max-width:100%;margin:0 auto;float:none;clear:both;box-sizing:border-box;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eMode group\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eNumber stated\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl ventilation\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSIMV\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure support ventilation\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eThe source lists these three groups without identifying every individual mode. They are described for anaesthesia induction, maintenance, recovery and spontaneous breathing practice.\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eAdvanced fresh-gas control system\u003c\/h2\u003e\n\u003cp\u003eElectronic closed-loop control allows the anaesthetist to set oxygen concentration directly. The system then adjusts the ratio of oxygen to balance gas. Real-time correction of oxygen concentration and total flow is designed to address flow errors associated with fluid inertia.\u003c\/p\u003e\n\u003cp\u003eThe Best Flow Indicator Tool displays the flow associated with current anaesthesia ventilation and supports consideration of low-flow anaesthesia. Its colour-spectrum diagram follows the manufacturer’s alarm-colour design to make the current flow value easier to interpret.\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eControl system and pressure indication\u003c\/h2\u003e\n\u003cp\u003eFresh-gas control uses an independent \u003cstrong\u003e8-inch LED touchscreen\u003c\/strong\u003e, providing a separate operating area with detailed flow information. The source does not identify this screen as the main ventilation display.\u003c\/p\u003e\n\u003cp\u003eAn electronic gas-source pressure gauge provides pressure indication without a mechanical pointer. The manufacturer describes this as avoiding pointer inertia.\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eProduct benefits and applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSeparate fresh-gas controls provide a dedicated area for flow adjustment and observation.\u003c\/li\u003e\n\u003cli\u003eRespiratory monitoring and breathing-parameter adjustment support anaesthesia management during surgical procedures.\u003c\/li\u003e\n\u003cli\u003eVentilation groups support induction, maintenance, recovery and spontaneous breathing practice.\u003c\/li\u003e\n\u003cli\u003eThe Best Flow Indicator Tool supports fresh-gas usage assessment during low-flow anaesthesia.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003cdiv class=\"nv-table-wrap\" style=\"width:100%;max-width:100%;margin:0 auto;float:none;clear:both;overflow-x:auto;box-sizing:border-box;\"\u003e\u003ctable style=\"width:100%;max-width:100%;margin:0 auto;float:none;clear:both;box-sizing:border-box;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSupplied information\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eCOMEN (Shenzhen Comen Medical Instruments Co., Ltd.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAX-900\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eAnaesthesia workstation with integrated ventilator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive and control\u003c\/td\u003e\n\u003ctd\u003eAscending bellows with pneumatic drive and electronic control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVentilation mode groups\u003c\/td\u003e\n\u003ctd\u003eFour control ventilation modes, three SIMV modes and two pressure support ventilation modes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVentilation accuracy\u003c\/td\u003e\n\u003ctd\u003e7%, as stated in the supplied page; tolerance definition not provided\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage\u003c\/td\u003e\n\u003ctd\u003e65 ml\/min, as stated in the supplied page; test conditions not provided\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePEEP\u003c\/td\u003e\n\u003ctd\u003eSupports clinician-directed lung protection and recruitment manoeuvres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoclavability\u003c\/td\u003e\n\u003ctd\u003eListed as “Autoclavable”; applicable components and validated processing conditions require confirmation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFresh-gas control\u003c\/td\u003e\n\u003ctd\u003eElectronic closed-loop control with direct oxygen-concentration setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic adjustment\u003c\/td\u003e\n\u003ctd\u003eOxygen-to-balance-gas ratio, oxygen concentration and total-flow correction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow indicator\u003c\/td\u003e\n\u003ctd\u003eBest Flow Indicator Tool with colour-spectrum display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDedicated flow-control screen\u003c\/td\u003e\n\u003ctd\u003e8-inch LED touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas-source pressure indication\u003c\/td\u003e\n\u003ctd\u003eElectronic pressure gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eRespiratory monitoring functions and breathing-parameter adjustment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection class=\"nv-note\"\u003e\u003ch2\u003eManufacturer information requiring verification\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm the definition and test conditions of the stated 7% ventilation accuracy. The source does not identify whether this is a ± tolerance.\u003c\/li\u003e\n\u003cli\u003eConfirm the pressure conditions and measurement method for the stated leakage of 65 ml\/min.\u003c\/li\u003e\n\u003cli\u003eConfirm the full ventilation mode list, available settings and patient-specific operating ranges.\u003c\/li\u003e\n\u003cli\u003eConfirm which components are autoclavable, together with the validated temperature, cycle and reprocessing instructions.\u003c\/li\u003e\n\u003cli\u003eConfirm the numerical specification and comparison basis for the stated higher compression capacity.\u003c\/li\u003e\n\u003cli\u003eConfirm installed monitoring functions, standard accessories, available options and gas supply requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDimensions, weight, power requirements, main ventilation display size and construction materials are not specified in the supplied page.\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eProduct documentation\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/alioss.comen.com\/cms-v2\/AX_900_AX_900_A_ed8a9cab6a.pdf\" target=\"_blank\" rel=\"noopener\"\u003eManufacturer product safety and performance information\u003c\/a\u003e\u003c\/p\u003e\u003c\/section\u003e\u003csection class=\"nv-contact\"\u003e\u003ch2\u003eCOMEN AX-900 Anaesthesia Workstation from Nass Ventures\u003c\/h2\u003e\n\u003cp\u003eContact Nass Ventures for pricing, configuration, compatible accessories, installation requirements and technical support.\u003c\/p\u003e\u003c\/section\u003e\n\u003c\/div\u003e","brand":"COMEN","offers":[{"title":"Default Title","offer_id":64757570208121,"sku":"AX-900","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6977\/8041\/files\/ccc.png?v=1790876047","url":"https:\/\/www.nassventures-africa.com\/products\/comen-ax900-anaesthesia-workstation","provider":"My Store","version":"1.0","type":"link"}