{"product_id":"comen-x8-anaesthesia-machine","title":"COMEN X8 Anaesthesia Machine","description":"\u003cstyle\u003e\n#nv-comen-x8, #nv-comen-x8 * {box-sizing:border-box !important;}\n#nv-comen-x8 {display:block !important;width:100% !important;max-width:1000px !important;margin:0 auto !important;float:none !important;clear:both !important;position:static !important;color:#263341;font-family:Arial,Helvetica,sans-serif;line-height:1.7;overflow-wrap:anywhere;}\n#nv-comen-x8 section {display:block !important;width:100% !important;max-width:100% !important;margin:0 auto 28px !important;float:none !important;clear:both !important;position:static !important;}\n#nv-comen-x8 h2 {font-size:24px;line-height:1.35;color:#173e54;margin:0 0 14px;text-align:left;}\n#nv-comen-x8 h3 {font-size:18px;line-height:1.45;color:#173e54;margin:0 0 9px;text-align:left;}\n#nv-comen-x8 p {margin:0 0 14px;text-align:left;}\n#nv-comen-x8 .nv-intro {padding:24px;background:#f1f6f8;border:1px solid #dce5e9;border-radius:8px;}\n#nv-comen-x8 .nv-grid {display:grid !important;grid-template-columns:repeat(2,minmax(0,1fr)) !important;gap:16px !important;width:100% !important;max-width:100% !important;margin:0 auto !important;float:none !important;clear:both !important;position:static !important;}\n#nv-comen-x8 .nv-card {display:block !important;min-width:0 !important;width:100% !important;margin:0 !important;padding:20px;background:#fff;border:1px solid #dde3e8;border-radius:7px;float:none !important;position:static !important;}\n#nv-comen-x8 .nv-card p:last-child {margin-bottom:0;}\n#nv-comen-x8 .nv-table-wrap {display:block !important;width:100% !important;max-width:100% !important;margin:0 auto !important;float:none !important;clear:both !important;overflow-x:auto !important;position:static !important;}\n#nv-comen-x8 table {display:table !important;width:100% !important;max-width:100% !important;margin:0 auto !important;float:none !important;clear:both !important;border-collapse:collapse !important;table-layout:fixed !important;position:static !important;}\n#nv-comen-x8 th,#nv-comen-x8 td {padding:13px 15px;border:1px solid #d9dfe4;vertical-align:top;white-space:normal !important;overflow-wrap:anywhere;}\n#nv-comen-x8 th {background:#f0f2f4;text-align:left;font-weight:600;}\n#nv-comen-x8 td:first-child {width:35%;text-align:left;}\n#nv-comen-x8 td:nth-child(2) {text-align:left;}\n#nv-comen-x8 ul {margin:0 0 16px;padding-left:22px;text-align:left;}\n#nv-comen-x8 li {margin:0 0 7px;}\n#nv-comen-x8 .nv-note {padding:20px;background:#faf8f2;border:1px solid #e3dbbf;border-radius:7px;}\n#nv-comen-x8 .nv-contact {padding:24px;background:#edf4f7;border:1px solid #d9e5eb;border-radius:8px;}\n@media(max-width:640px){#nv-comen-x8 .nv-grid {grid-template-columns:minmax(0,1fr) !important;}#nv-comen-x8 h2 {font-size:21px;}#nv-comen-x8 .nv-intro,#nv-comen-x8 .nv-contact,#nv-comen-x8 .nv-note {padding:18px;}#nv-comen-x8 th,#nv-comen-x8 td {padding:10px;font-size:14px;}}\n\u003c\/style\u003e\n\u003cdiv id=\"nv-comen-x8\" style=\"width:100%;max-width:1000px;margin:0 auto;float:none;clear:both;box-sizing:border-box;\"\u003e\n\u003csection class=\"nv-intro\"\u003e\n\u003ch2\u003eCOMEN X8 Anaesthesia Machine\u003c\/h2\u003e\n\u003cp\u003eCOMEN X8 anaesthesia workstation with electronic fresh-gas control, nine ventilation modes, an 18.5-inch touchscreen, integrated modules and perioperative management tools.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eCOMEN X8\u003c\/strong\u003e brings fresh-gas delivery, ventilation support, monitoring modules and anaesthesia management functions together in an integrated workstation. Its electronic flowmeter and econometer support fresh-gas control and low-flow anaesthesia, while its ventilation modes and lung protection tools support management throughout the perioperative process.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\n\u003cdiv class=\"nv-grid\"\u003e\n\u003cdiv class=\"nv-card\"\u003e\n\u003ch3\u003eElectronic fresh-gas control\u003c\/h3\u003e\n\u003cp\u003eDirectly set FiO2 and total flow using the electronic flowmeter. The econometer provides real-time fresh-gas usage information to guide low-flow anaesthesia and help limit unnecessary anaesthetic agent waste.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"nv-card\"\u003e\n\u003ch3\u003eVentilation support\u003c\/h3\u003e\n\u003cp\u003eNine listed modes cover mechanical, adaptive, synchronised and support ventilation: VCV, PCV, PSV\/CPAP, SIMV-VC, SIMV-PC, SIMV-PRVC, PRVC, AMV and APRV.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"nv-card\"\u003e\n\u003ch3\u003eTouchscreen interface\u003c\/h3\u003e\n\u003cp\u003eAn \u003cstrong\u003e18.5-inch capacitive touchscreen\u003c\/strong\u003e displays multiple parameters on one screen. The manufacturer describes 360-degree rotation to accommodate different clinician positions and working preferences.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"nv-card\"\u003e\n\u003ch3\u003ePerioperative management\u003c\/h3\u003e\n\u003cp\u003eHigh-flow oxygen therapy, lung recruitment tools, respiratory monitoring functions and data interconnection support a continuous perioperative workflow.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\n\u003csection\u003e\u003ch2\u003eGas delivery and operating principles\u003c\/h2\u003e\n\u003cp\u003eThe electronic flowmeter allows anaesthetists to set the inspired oxygen fraction (FiO2) and total fresh-gas flow directly. The econometer displays fresh-gas usage information during operation to support low-flow anaesthesia management.\u003c\/p\u003e\n\u003cp\u003eThe supplied manufacturer page lists breathing-circuit leakage of \u003cstrong\u003e49.5 ml\u003c\/strong\u003e, ventilation deviation of \u003cstrong\u003e7%\u003c\/strong\u003e and a sampling-response figure of \u003cstrong\u003e1,000 Hz\u003c\/strong\u003e. These figures are reproduced without changing their stated meaning. Their definitions and test conditions require manufacturer confirmation, as detailed below.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection\u003e\u003ch2\u003eVentilation modes\u003c\/h2\u003e\n\u003cp\u003eThe manufacturer describes the X8 as providing ICU-level ventilation support for perioperative use, with mechanical, adaptive, synchronised and support ventilation options.\u003c\/p\u003e\n\u003cdiv class=\"nv-table-wrap\" style=\"width:100%;max-width:100%;margin:0 auto;float:none;clear:both;overflow-x:auto;box-sizing:border-box;\"\u003e\u003ctable style=\"width:100%;max-width:100%;margin:0 auto;float:none;clear:both;box-sizing:border-box;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eFunction\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eManufacturer information\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eListed ventilation modes\u003c\/td\u003e\n\u003ctd\u003eVCV, PCV, PSV\/CPAP, SIMV-VC, SIMV-PC, SIMV-PRVC, PRVC, AMV, APRV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdaptive Minute Ventilation (AMV)\u003c\/td\u003e\n\u003ctd\u003eListed as a supported ventilation mode. The explanatory paragraph supplied under this heading requires verification.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirway Pressure Release Ventilation (APRV)\u003c\/td\u003e\n\u003ctd\u003eUses sustained airway pressure with short pressure-release periods. The manufacturer describes this mode in relation to the open-lung principle and preservation of spontaneous breathing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\n\u003csection\u003e\u003ch2\u003eIntegrated modules and breathing circuit\u003c\/h2\u003e\n\u003cp\u003eThe manufacturer lists the following modules and systems. Confirm the supplied configuration and module availability when requesting a quotation.\u003c\/p\u003e\n\u003cdiv class=\"nv-grid\"\u003e\n\u003cdiv class=\"nv-card\"\u003e\n\u003ch3\u003eBuilt-in AGSS\u003c\/h3\u003e\n\u003cp\u003eActive anaesthetic waste-gas absorption.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"nv-card\"\u003e\n\u003ch3\u003eModular breathing circuit\u003c\/h3\u003e\n\u003cp\u003eAn integrated modular design supports maintenance and disinfection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"nv-card\"\u003e\n\u003ch3\u003eBIS module\u003c\/h3\u003e\n\u003cp\u003eProvides an anaesthesia depth indication for intraoperative management.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"nv-card\"\u003e\n\u003ch3\u003eNegative pressure suction\u003c\/h3\u003e\n\u003cp\u003eA dedicated suction system provides airway assistance for anaesthetists.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\n\u003csection\u003e\u003ch2\u003eHigh-flow oxygen therapy and lung protection tools\u003c\/h2\u003e\n\u003cp\u003eThe X8 offers continuous high-flow, high-concentration oxygen delivery for perioperative oxygen support. Its lung protection functions provide tools for clinician-directed respiratory management.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLung recruitment tools based on the PEEP increment method.\u003c\/li\u003e\n\u003cli\u003eOesophageal pressure monitoring.\u003c\/li\u003e\n\u003cli\u003eSigh ventilation.\u003c\/li\u003e\n\u003cli\u003eInspiratory hold and expiratory hold.\u003c\/li\u003e\n\u003cli\u003eA VT\/IBW tool for ideal tidal volume calculation and guidance on low tidal volume settings.\u003c\/li\u003e\n\u003cli\u003eSpontaneous breathing modes for use across perioperative stages.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\n\u003csection\u003e\u003ch2\u003eControl system and anaesthesia management\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSoda lime tank in-place reminders support operational checks and management of leakage risks.\u003c\/li\u003e\n\u003cli\u003eAnaesthesia data review and printing support record archiving and post-case traceability.\u003c\/li\u003e\n\u003cli\u003eQuick startup and rapid self-tests support preparation for emergency use.\u003c\/li\u003e\n\u003cli\u003eVisual self-checking procedures guide operators through system checks.\u003c\/li\u003e\n\u003cli\u003eGas usage monitoring and anaesthesia consumption warnings support resource management.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\n\u003csection\u003e\u003ch2\u003eData interconnection and applications\u003c\/h2\u003e\n\u003cp\u003eConnection to a data platform through integration equipment supports continuous perioperative data interconnection. The manufacturer describes workflows covering emergency surgery, elective surgery, painless surgery and day surgery.\u003c\/p\u003e\n\u003cp\u003eConfirm the required integration equipment, platform compatibility and local implementation requirements with Nass Ventures before specifying a connected installation.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection\u003e\u003ch2\u003eTechnical specifications and product information\u003c\/h2\u003e\n\u003cdiv class=\"nv-table-wrap\" style=\"width:100%;max-width:100%;margin:0 auto;float:none;clear:both;overflow-x:auto;box-sizing:border-box;\"\u003e\u003ctable style=\"width:100%;max-width:100%;margin:0 auto;float:none;clear:both;box-sizing:border-box;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSupplied information\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eCOMEN (Shenzhen Comen Medical Instruments Co., Ltd.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eX8\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eIntegrated anaesthesia machine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e18.5-inch capacitive touchscreen with multi-parameter display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRotation\u003c\/td\u003e\n\u003ctd\u003e360 degrees, as stated by the manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFresh-gas control\u003c\/td\u003e\n\u003ctd\u003eElectronic flowmeter with direct FiO2 and total-flow setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFresh-gas usage guidance\u003c\/td\u003e\n\u003ctd\u003eReal-time econometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreathing-circuit leakage\u003c\/td\u003e\n\u003ctd\u003e49.5 ml, as supplied; measurement conditions not stated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVentilation deviation\u003c\/td\u003e\n\u003ctd\u003e7%, as supplied; tolerance definition not stated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling response\u003c\/td\u003e\n\u003ctd\u003e1,000 Hz, as supplied; measurement definition not stated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVentilation modes\u003c\/td\u003e\n\u003ctd\u003eVCV, PCV, PSV\/CPAP, SIMV-VC, SIMV-PC, SIMV-PRVC, PRVC, AMV, APRV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListed modules and systems\u003c\/td\u003e\n\u003ctd\u003eBuilt-in AGSS, modular breathing circuit, BIS module and negative pressure suction system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen therapy\u003c\/td\u003e\n\u003ctd\u003eContinuous high-flow, high-concentration oxygen delivery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLung recruitment method\u003c\/td\u003e\n\u003ctd\u003ePEEP increment method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional respiratory tools\u003c\/td\u003e\n\u003ctd\u003eOesophageal pressure monitoring, sigh ventilation, inspiratory hold, expiratory hold and VT\/IBW tool\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData functions\u003c\/td\u003e\n\u003ctd\u003eData review, printing and platform interconnection through integration equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperational checks\u003c\/td\u003e\n\u003ctd\u003eSoda lime tank reminders, rapid self-tests, visual self-checking and consumption warnings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\n\u003csection class=\"nv-note\"\u003e\u003ch2\u003eManufacturer information requiring verification\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm the leakage measurement basis for 49.5 ml, including any applicable time interval and pressure conditions.\u003c\/li\u003e\n\u003cli\u003eConfirm the definition and test conditions for 7% ventilation deviation and the meaning of the 1,000 Hz sampling-response figure.\u003c\/li\u003e\n\u003cli\u003eConfirm which assembly provides the stated 360-degree rotation.\u003c\/li\u003e\n\u003cli\u003eThe supplied AMV section contains an apparently unrelated control-system paragraph. It reads: “The override control panel and hand remote are on standby. The override control panel enables all movements in case of hand remote failure. The wall panel and remote control are optional.” This wording requires manufacturer verification and is not presented here as a confirmed X8 control-system specification.\u003c\/li\u003e\n\u003cli\u003eConfirm standard and optional modules, accessories and integration equipment for the selected configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDimensions, weight, power requirements, gas supply requirements and construction materials are not specified in the supplied product page.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection\u003e\u003ch2\u003eProduct documentation\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/alioss.comen.com\/cms-v2\/X5_X6_X7_X8_1_2116d41f0e.pdf\" target=\"_blank\" rel=\"noopener\"\u003eManufacturer product safety and performance information for the X5\/X6\/X7\/X8 family\u003c\/a\u003e\u003c\/p\u003e\u003c\/section\u003e\n\u003csection class=\"nv-contact\"\u003e\u003ch2\u003eCOMEN X8 from Nass Ventures\u003c\/h2\u003e\n\u003cp\u003eThe X8 combines fresh-gas control, ventilation modes, an integrated touchscreen interface and perioperative management functions in one anaesthesia workstation.\u003c\/p\u003e\n\u003cp\u003eContact Nass Ventures for pricing, configuration, compatible accessories, installation requirements and technical support.\u003c\/p\u003e\u003c\/section\u003e\n\u003c\/div\u003e","brand":"COMEN","offers":[{"title":"Default Title","offer_id":64757331820921,"sku":"X8","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6977\/8041\/files\/bbbbbbb_77eb5a6e-d859-4560-8bf3-862ae3554fc0.png?v=1790877927","url":"https:\/\/www.nassventures-africa.com\/products\/comen-x8-anaesthesia-machine","provider":"My Store","version":"1.0","type":"link"}