{"product_id":"envair-safety-cabinet-eco-safe-plus-class-ii-in-laminar-flow-boxes-pcr-workstations-biological-safety-cabinets","title":"ENVAIR Safety cabinet eco safe Plus Class II in Laminar Flow Boxes, PCR Workstations, Biological Safety Cabinets","description":"\u003carticle\u003e\n\n\u003cp\u003e\u003cstrong\u003eENVAIR Safety cabinet eco safe Plus Class II\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eENVAIR eco safe Plus Cytotxic Safety Cabinets belong to the latest generation of laminar airflow systems, in which the choice of materials of construction of the highest quality guarantees conformity to the strictest safety standards.\u003c\/p\u003e\n\n\u003cp\u003eENVAIR eco safe Plus vertical laminar flow cabinets are Class II Microbiological Safety Cabinets - designed and built to performance requirements of the EN-12469: 2000 European Standard, with 70% of the air re-circulated via the main Class H14 HEPA filter within the cabinet, whilst the remaining 30% is discharged through an exhaust Class H14 HEPA filter.\u003c\/p\u003e\n\n\u003cp\u003eSafety Cabinets with automatic regulation and microprocessor based monitoring systems. These cabinets are suitable for handling micro-organisms and pathogens as defined by the appropriate European and other International Standards, current health and safety guidelines and legislation aimed at safeguarding health and safety of operators at work.\u003c\/p\u003e\n\n\u003cp\u003eRespect for the environment motivates ENVAIR to manufacture laminar-flow, cytotoxic drug safety cabinets and microbiological safety cabinets possessing ultra-low environmental impact, by utilizing:\u003cbr\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eCertified ''low pressure-drop'' HEPA filters providing up to 30% saving on power consumption \n\u003c\/li\u003e\n\u003cli\u003eElectronically controlled motor-blower with automatic pressure-drop compensation \n\u003c\/li\u003e\n\u003cli\u003e99% recyclable components \n\u003c\/li\u003e\n\u003cli\u003eInnovative technologies such as the new ECS® microprocessor\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eECS® Microprocessor based monitoring system: full status report provided via 2-line digital display by the new generation microprocessors - which automatically control all functions and all safety alarm systems ensuring that performance characteristics are maintained to EN12469: 2000 requirements. High power lithium battery keeps safety data saved to microprocessor system. The user-friendly practical keyboard and the rear-lit LCD will continuously display all required data keeping the user constantly informed of the cabinet conditions in operation and in particular:\u003cbr\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003edisplay of laminar airflow velocity and frontal air barrier velocity \n\u003c\/li\u003e\n\u003cli\u003edisplay of inside and outside temperature \n\u003c\/li\u003e\n\u003cli\u003edisplay of residual lifetime of HEPA filters, UV Lamp (if fitted) \n\u003c\/li\u003e\n\u003cli\u003edisplay of total number of hours of operation \n\u003c\/li\u003e\n\u003cli\u003edisplay of saturation level of HEPA filters  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eAudio visual alarms provided for:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eout of range or incorrect laminar airflow velocity and frontal air barrier velocity \n\u003c\/li\u003e\n\u003cli\u003euncorrect position of front sash-window \n\u003c\/li\u003e\n\u003cli\u003esaturation of HEPA filters \n\u003c\/li\u003e\n\u003cli\u003eend of life-cycle of UV lamp (if fitted) \n\u003c\/li\u003e\n\u003cli\u003eblockage in the exhaust duct \n\u003c\/li\u003e\n\u003cli\u003efan-motor malfunction \n\u003c\/li\u003e\n\u003cli\u003epower failure\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eCertification: ISO 9001 certified\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eOperational Principles\u003cbr\u003e\u003c\/strong\u003eThe ambient air is drawn in from the slots at the stainless steel base of the front opening and it then passes through the H14 HEPA filter bank below work surface from where it is drawn up and blown into the plenum of the recirculating and exhaust fan.The ''bio-dynamic sealing system'' of the negative pressure plenum ensures that all contaminated particles are kept inside the system and are automatically drawn to the plenum or pressure chamber to be captured by the main re-circulating and exhaust H14 HEPA filters.The fan system assures that no part of the cabinet comes even under positive contaminated pressure to the laboratory, thus protecting and preserving the environment and operating personell from exposure to cytotoxic drug, CMR compounds and agents of biocontamination. 70% of the filtered air is re-circulated (after passing through double banks of H14 HEPA filters) In an ISO 3 laminar flow pattern downwards into the work chamber and the remaining 30% is exhausted to atmosphere through another H14 HEPA filter.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eConfiguration overview:\u003c\/strong\u003e \u003cbr\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eElectrical upwards opening frontal screen for easy cleaning \n\u003c\/li\u003e\n\u003cli\u003eVacuum connection \n\u003c\/li\u003e\n\u003cli\u003eSafety service connection for gas \n\u003c\/li\u003e\n\u003cli\u003e1 electrical socket at 0.9 m and 1.2 m \n\u003c\/li\u003e\n\u003cli\u003e2 electrical sockets at 1.5 m and 1.8 m \n\u003c\/li\u003e\n\u003cli\u003eOperation mode for overnight-reduction \n\u003c\/li\u003e\n\u003cli\u003eAnti bacterial coating \n\u003c\/li\u003e\n\u003cli\u003eLow noise level \n\u003c\/li\u003e\n\u003cli\u003eStainless steel AISI 316L \n\u003c\/li\u003e\n\u003cli\u003eReal Laminar Flow\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e glass in the rear wall for the installation a monitor and media connections when ordering with specify a retrofit is not possible.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eCustomizing services (Selection)\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e24h at site service and 24h free of charge phone hotline, 7 days a week \n\u003c\/li\u003e\n\u003cli\u003e10 years Spare parts guaranty. Availability within 24h \n\u003c\/li\u003e\n\u003cli\u003eQualification: IQ\/OQ, GMP, GAMP and 21 CFR Part 11 \n\u003c\/li\u003e\n\u003cli\u003eWe offer a 2-year warranty to all units (with maintenance contract)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/article\u003e","brand":"FASTER GmbH","offers":[{"title":"0.9 mPrice on application","offer_id":56332524716409,"sku":"ENVAIR_9005\u003e-0-9-mprice-on-application","price":0.0,"currency_code":"NGN","in_stock":true},{"title":"1.2 mPrice on application","offer_id":56332524749177,"sku":"ENVAIR_9005\u003e-1-2-mprice-on-application","price":0.0,"currency_code":"NGN","in_stock":true},{"title":"1.5 mPrice on application","offer_id":56332524781945,"sku":"ENVAIR_9005\u003e-1-5-mprice-on-application","price":0.0,"currency_code":"NGN","in_stock":true},{"title":"1.8 mPrice on application","offer_id":56332524814713,"sku":"ENVAIR_9005\u003e-1-8-mprice-on-application","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6977\/8041\/files\/de-labor-laminarboxen-pcr-boxen-sicherheitswerkbaenke-envair-sicherheitswerkbank-eco-safe-plus-klasse-ii_acdc7331-cd6e-49ca-8e74-56ceeb23b259.jpg?v=1765210968","url":"https:\/\/www.nassventures-africa.com\/products\/envair-safety-cabinet-eco-safe-plus-class-ii-in-laminar-flow-boxes-pcr-workstations-biological-safety-cabinets","provider":"My Store","version":"1.0","type":"link"}