{"product_id":"labbox-lbx-r-chemically-resistant-vacuum-pump","title":"Labbox LBX R Chemically Resistant Vacuum Pump","description":"\u003cstyle\u003e\n#nv-labbox-lbx-r-chemically-resistant-vacuum-pump, #nv-labbox-lbx-r-chemically-resistant-vacuum-pump * {box-sizing:border-box !important;}\n#nv-labbox-lbx-r-chemically-resistant-vacuum-pump {display:block !important;width:100% !important;max-width:1000px !important;margin:0 auto !important;float:none !important;clear:both !important;position:static !important;color:#263341;font-family:Arial,Helvetica,sans-serif;line-height:1.7;overflow-wrap:anywhere;}\n#nv-labbox-lbx-r-chemically-resistant-vacuum-pump section {display:block !important;width:100% !important;max-width:100% !important;margin:0 auto 28px !important;float:none !important;clear:both !important;position:static !important;}\n#nv-labbox-lbx-r-chemically-resistant-vacuum-pump h2 {font-size:24px;line-height:1.35;color:#173e54;margin:0 0 14px;text-align:left;}\n#nv-labbox-lbx-r-chemically-resistant-vacuum-pump h3 {font-size:18px;line-height:1.45;color:#173e54;margin:0 0 9px;text-align:left;}\n#nv-labbox-lbx-r-chemically-resistant-vacuum-pump p {margin:0 0 14px;text-align:left;}\n#nv-labbox-lbx-r-chemically-resistant-vacuum-pump .nv-intro {padding:24px;background:#f1f6f8;border:1px solid #dce5e9;border-radius:8px;}\n#nv-labbox-lbx-r-chemically-resistant-vacuum-pump .nv-grid {display:grid !important;grid-template-columns:repeat(2,minmax(0,1fr)) !important;gap:16px !important;width:100% !important;max-width:100% !important;margin:0 auto !important;float:none !important;clear:both !important;position:static !important;}\n#nv-labbox-lbx-r-chemically-resistant-vacuum-pump .nv-card {display:block !important;min-width:0 !important;width:100% !important;margin:0 !important;padding:20px;background:#fff;border:1px solid #dde3e8;border-radius:7px;float:none !important;position:static !important;}\n#nv-labbox-lbx-r-chemically-resistant-vacuum-pump .nv-card p:last-child {margin-bottom:0;}\n#nv-labbox-lbx-r-chemically-resistant-vacuum-pump .nv-table-wrap {display:block !important;width:100% !important;max-width:100% !important;margin:0 auto !important;float:none !important;clear:both !important;overflow-x:auto !important;position:static !important;}\n#nv-labbox-lbx-r-chemically-resistant-vacuum-pump table {display:table !important;width:100% !important;max-width:100% !important;margin:0 auto !important;float:none !important;clear:both !important;border-collapse:collapse !important;table-layout:fixed !important;position:static !important;}\n#nv-labbox-lbx-r-chemically-resistant-vacuum-pump th,#nv-labbox-lbx-r-chemically-resistant-vacuum-pump td {padding:13px 15px;border:1px solid #d9dfe4;vertical-align:top;white-space:normal !important;overflow-wrap:anywhere;}\n#nv-labbox-lbx-r-chemically-resistant-vacuum-pump th {background:#f0f2f4;text-align:left;font-weight:600;}\n#nv-labbox-lbx-r-chemically-resistant-vacuum-pump td:first-child {width:35%;text-align:left;}\n#nv-labbox-lbx-r-chemically-resistant-vacuum-pump td:nth-child(2) {text-align:left;}\n#nv-labbox-lbx-r-chemically-resistant-vacuum-pump ul {margin:0 0 16px;padding-left:22px;text-align:left;}\n#nv-labbox-lbx-r-chemically-resistant-vacuum-pump li {margin:0 0 7px;}\n#nv-labbox-lbx-r-chemically-resistant-vacuum-pump .nv-note {padding:20px;background:#faf8f2;border:1px solid #e3dbbf;border-radius:7px;}\n#nv-labbox-lbx-r-chemically-resistant-vacuum-pump .nv-contact {padding:24px;background:#edf4f7;border:1px solid #d9e5eb;border-radius:8px;}\n@media(max-width:640px){#nv-labbox-lbx-r-chemically-resistant-vacuum-pump .nv-grid {grid-template-columns:minmax(0,1fr) !important;}#nv-labbox-lbx-r-chemically-resistant-vacuum-pump h2 {font-size:21px;}#nv-labbox-lbx-r-chemically-resistant-vacuum-pump .nv-intro,#nv-labbox-lbx-r-chemically-resistant-vacuum-pump .nv-contact,#nv-labbox-lbx-r-chemically-resistant-vacuum-pump .nv-note {padding:18px;}#nv-labbox-lbx-r-chemically-resistant-vacuum-pump th,#nv-labbox-lbx-r-chemically-resistant-vacuum-pump td {padding:10px;font-size:14px;}}\n\u003c\/style\u003e\n\u003cdiv id=\"nv-labbox-lbx-r-chemically-resistant-vacuum-pump\" style=\"width:100%;max-width:1000px;margin:0 auto;float:none;clear:both;box-sizing:border-box;\"\u003e\n\u003csection class=\"nv-intro\"\u003e\u003ch2\u003eLabbox LBX R Chemically Resistant Vacuum Pump\u003c\/h2\u003e\n\u003cp\u003eOil-free, chemically resistant laboratory vacuum pumps with PTFE wetted parts, 18 l\/min flow and a choice of R10 or R20 models.\u003c\/p\u003e\n\u003cp\u003eThe LBX R series provides oil-free vacuum for compatible laboratory filtration, solid-phase extraction and gel-related workflows. PTFE wetted parts provide chemical resistance, subject to compatibility with the actual gases, vapours and process.\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\n\u003cdiv class=\"nv-grid\"\u003e\n\u003cdiv class=\"nv-card\"\u003e\n\u003ch3\u003ePTFE wetted parts\u003c\/h3\u003e\n\u003cp\u003eAll wetted parts are specified as PTFE for chemical resistance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"nv-card\"\u003e\n\u003ch3\u003eOil-free operation\u003c\/h3\u003e\n\u003cp\u003eNo lubricating oil is required; carry out the routine checks and maintenance specified in the manual.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"nv-card\"\u003e\n\u003ch3\u003eTwo vacuum levels\u003c\/h3\u003e\n\u003cp\u003eR10 and R20 share an 18 l\/min atmospheric flow rating but provide different vacuum levels and power ratings.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"nv-card\"\u003e\n\u003ch3\u003eThermal protection\u003c\/h3\u003e\n\u003cp\u003eOverheating protection is incorporated. The manufacturer lists a 50 dB noise level and 1450 rpm motor speed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003cdiv class=\"nv-table-wrap\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand \/ range\u003c\/th\u003e\n\u003ctd\u003eLBX instruments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFlow rate at atmospheric pressure\u003c\/th\u003e\n\u003ctd\u003e18 l\/min, both models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWetted parts\u003c\/th\u003e\n\u003ctd\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLubricating oil\u003c\/th\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMains supply\u003c\/th\u003e\n\u003ctd\u003e220 V \/ 50 Hz; confirm unit rating and plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor speed\u003c\/th\u003e\n\u003ctd\u003e1450 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNoise level\u003c\/th\u003e\n\u003ctd\u003e50 dB, manufacturer specification; test conditions not stated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eThermal protection\u003c\/th\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eR10 maximum vacuum\u003c\/th\u003e\n\u003ctd\u003e99 mbar absolute \/ 685 mmHg relative, catalogue specification; confirm required performance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eR10 maximum power\u003c\/th\u003e\n\u003ctd\u003e60 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eR10 dimensions, L × W × H\u003c\/th\u003e\n\u003ctd\u003e200 × 110 × 210 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eR20 maximum vacuum\u003c\/th\u003e\n\u003ctd\u003e10 mbar absolute \/ 752 mmHg relative, catalogue specification; confirm required performance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eR20 maximum power\u003c\/th\u003e\n\u003ctd\u003e90 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eR20 dimensions, L × W × H\u003c\/th\u003e\n\u003ctd\u003e260 × 150 × 180 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHose connection\u003c\/th\u003e\n\u003ctd\u003eØ8 mm, both models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRotary evaporator application\u003c\/th\u003e\n\u003ctd\u003eR20 only, subject to system and solvent compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePack quantity\u003c\/th\u003e\n\u003ctd\u003e1 pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eConfirm the term applicable to the supplied model in the quotation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eAvailable variants\u003c\/h2\u003e\n\u003cdiv class=\"nv-table-wrap\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eReference\u003c\/th\u003e\n\u003cth\u003eVariant\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVACU-R10-001\u003c\/td\u003e\n\u003ctd\u003eR10 — 99 mbar; 18 l\/min; 99 mbar absolute; 60 W; 200 × 110 × 210 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVACU-R20-001\u003c\/td\u003e\n\u003ctd\u003eR20 — 10 mbar; 18 l\/min; 10 mbar absolute; 90 W; 260 × 150 × 180 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eSupply and accessories\u003c\/h2\u003e\n\u003cp\u003eOne pump in the selected model. A vacuum trap is recommended and is essential when using a filtration manifold. Trap, vacuum regulator, tubing and connected laboratory equipment are separate unless included in the quotation. The main photograph shows R10.\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eHandling and compatibility\u003c\/h2\u003e\n\u003cp\u003eConfirm chemical compatibility, required vacuum and system connections before ordering. The manuals prohibit use with flammable gases or toxic materials. Prevent liquid carry-over and follow the instructions for ventilation, operation and maintenance.\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eOrdering information\u003c\/h2\u003e\n\u003cp\u003eProvide the product reference, selected variant, quantity, delivery location and intended use. Include the required pack size or configuration, existing equipment, accessories and consumables, and any installation, training or maintenance requirements relevant to your order.\u003c\/p\u003e\u003c\/section\u003e\u003csection class=\"nv-contact\"\u003e\u003ch2\u003eDelivery, spares and service\u003c\/h2\u003e\n\u003cp\u003eContact Nass Ventures to confirm availability, delivery arrangements, compatible spares and service requirements. The quotation will define the final supplied configuration and documentation.\u003c\/p\u003e\u003c\/section\u003e\n\u003c\/div\u003e\n\u003c!-- SOURCE REVIEW: Uploaded supplier source https:\/\/labbox.eu\/product\/chemically-resistant-vacuum-pump-lbx-instruments-r-series\/. Verified manufacturer documents: https:\/\/labbox.eu\/wp-content\/uploads\/Manuales\/MANU_VACU-R10-001.pdf; https:\/\/labbox.eu\/wp-content\/uploads\/Manuales\/MANU_VACU-R20-001.pdf; https:\/\/labbox.eu\/wp-content\/uploads\/FT\/PDS-238.pdf; https:\/\/labbox.eu\/wp-content\/uploads\/IA\/IA_238.pdf; https:\/\/labbox.eu\/wp-content\/uploads\/CRT\/CE-238.pdf. WARRANTY CONFLICT: uploaded page\/PDS state 2 years; both model manuals state 48 months. No fixed warranty term promised. VACUUM CONFLICT: R10 manual heading gives −670 mmHg versus catalogue relative 685 mmHg; R20 manual gives −750 versus catalogue 752 mmHg. Catalogue values retained as explicitly labelled catalogue specifications, with required performance confirmation. IA_238 labels vacuum columns absolute\/relative; mbar values are not two equivalent units of the same pressure. Maintenance-free marketing omitted because manuals require regular maintenance. Only R20 is listed for rotary evaporators. No universal compatibility or flammable\/toxic service claim. R10 photograph is not mapped to R20. Barcode\/MPN mapped to orderable reference, not parent website SKU. Unknown inventory, condition and shipping weights remain blank. Net equipment weights and unverified logistics figures are not shipping weights. --\u003e\n\u003c!-- PRICING REVIEW: ECB 7 October 2026 EUR 1 = GBP 0.84645; source https:\/\/www.ecb.europa.eu\/stats\/policy_and_exchange_rates\/euro_reference_exchange_rates\/html\/index.en.html . Selling GBP = ROUND(supplier net EUR × 0.84645 × 1.35, 2). Cost GBP = ROUND(supplier net EUR × 0.84645, 2). Use unrounded converted cost when applying markup. Product prices exclude transport; no promotional discounts applied. Supplier net EUR by SKU: {\"VACU-R10-001\": \"1087.31\", \"VACU-R20-001\": \"1641.82\"}. Unknown prices and compare-at prices blank. --\u003e\n\u003c!-- IMAGE REVIEW: [{\"url\": \"https:\/\/labbox.eu\/wp-content\/uploads\/sites\/4\/2020\/07\/VACU-R10-001.jpg\", \"sku\": \"VACU-R10-001\", \"status\": 200, \"error\": null, \"origin\": null}] Images with HTTP 200 visually checked.  --\u003e","brand":"Labbox","offers":[{"title":"R10 — 99 mbar","offer_id":64816067150201,"sku":"VACU-R10-001","price":2354100.0,"currency_code":"NGN","in_stock":true},{"title":"R20 — 10 mbar","offer_id":64816067182969,"sku":"VACU-R20-001","price":3554700.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6977\/8041\/files\/VACU-R10-001.jpg?v=1791390786","url":"https:\/\/www.nassventures-africa.com\/products\/labbox-lbx-r-chemically-resistant-vacuum-pump","provider":"My Store","version":"1.0","type":"link"}