{"product_id":"teac-ur-4md-full-hd-medical-video-recorder","title":"TEAC UR-4MD Full HD Medical Video Recorder","description":"\u003cstyle\u003e\n#nv-teac-ur-4md-full-hd-medical-video-recorder, #nv-teac-ur-4md-full-hd-medical-video-recorder * {box-sizing:border-box !important;}\n#nv-teac-ur-4md-full-hd-medical-video-recorder {display:block !important;width:100% !important;max-width:1000px !important;margin:0 auto !important;float:none !important;clear:both !important;position:static !important;color:#263341;font-family:Arial,Helvetica,sans-serif;line-height:1.7;overflow-wrap:anywhere;}\n#nv-teac-ur-4md-full-hd-medical-video-recorder section {display:block !important;width:100% !important;max-width:100% !important;margin:0 auto 28px !important;float:none !important;clear:both !important;position:static !important;}\n#nv-teac-ur-4md-full-hd-medical-video-recorder h2 {font-size:24px;line-height:1.35;color:#173e54;margin:0 0 14px;text-align:left;}\n#nv-teac-ur-4md-full-hd-medical-video-recorder h3 {font-size:18px;line-height:1.45;color:#173e54;margin:0 0 9px;text-align:left;}\n#nv-teac-ur-4md-full-hd-medical-video-recorder p {margin:0 0 14px;text-align:left;}\n#nv-teac-ur-4md-full-hd-medical-video-recorder .nv-intro {padding:24px;background:#f1f6f8;border:1px solid #dce5e9;border-radius:8px;}\n#nv-teac-ur-4md-full-hd-medical-video-recorder .nv-grid {display:grid !important;grid-template-columns:repeat(2,minmax(0,1fr)) !important;gap:16px !important;width:100% !important;max-width:100% !important;margin:0 auto !important;float:none !important;clear:both !important;position:static !important;}\n#nv-teac-ur-4md-full-hd-medical-video-recorder .nv-card {display:block !important;min-width:0 !important;width:100% !important;margin:0 !important;padding:20px;background:#fff;border:1px solid #dde3e8;border-radius:7px;float:none !important;position:static !important;}\n#nv-teac-ur-4md-full-hd-medical-video-recorder .nv-card p:last-child {margin-bottom:0;}\n#nv-teac-ur-4md-full-hd-medical-video-recorder .nv-table-wrap {display:block !important;width:100% !important;max-width:100% !important;margin:0 auto !important;float:none !important;clear:both !important;overflow-x:auto !important;position:static !important;}\n#nv-teac-ur-4md-full-hd-medical-video-recorder table {display:table !important;width:100% !important;max-width:100% !important;margin:0 auto !important;float:none !important;clear:both !important;border-collapse:collapse !important;table-layout:fixed !important;position:static !important;}\n#nv-teac-ur-4md-full-hd-medical-video-recorder th,#nv-teac-ur-4md-full-hd-medical-video-recorder td {padding:13px 15px;border:1px solid #d9dfe4;vertical-align:top;white-space:normal !important;overflow-wrap:anywhere;}\n#nv-teac-ur-4md-full-hd-medical-video-recorder th {background:#f0f2f4;text-align:left;font-weight:600;}\n#nv-teac-ur-4md-full-hd-medical-video-recorder td:first-child {width:35%;text-align:left;}\n#nv-teac-ur-4md-full-hd-medical-video-recorder td:nth-child(2) {text-align:left;}\n#nv-teac-ur-4md-full-hd-medical-video-recorder ul {margin:0 0 16px;padding-left:22px;text-align:left;}\n#nv-teac-ur-4md-full-hd-medical-video-recorder li {margin:0 0 7px;}\n#nv-teac-ur-4md-full-hd-medical-video-recorder .nv-note {padding:20px;background:#faf8f2;border:1px solid #e3dbbf;border-radius:7px;}\n#nv-teac-ur-4md-full-hd-medical-video-recorder .nv-contact {padding:24px;background:#edf4f7;border:1px solid #d9e5eb;border-radius:8px;}\n@media(max-width:640px){#nv-teac-ur-4md-full-hd-medical-video-recorder .nv-grid {grid-template-columns:minmax(0,1fr) !important;}#nv-teac-ur-4md-full-hd-medical-video-recorder h2 {font-size:21px;}#nv-teac-ur-4md-full-hd-medical-video-recorder .nv-intro,#nv-teac-ur-4md-full-hd-medical-video-recorder .nv-contact,#nv-teac-ur-4md-full-hd-medical-video-recorder .nv-note {padding:18px;}#nv-teac-ur-4md-full-hd-medical-video-recorder th,#nv-teac-ur-4md-full-hd-medical-video-recorder td {padding:10px;font-size:14px;}}\n\n#nv-teac-ur-4md-full-hd-medical-video-recorder figure {min-width:0;width:100%;max-width:100%;margin:0 auto 20px;padding:18px;background:#fff;border:1px solid #dce5e9;border-radius:8px;}\n#nv-teac-ur-4md-full-hd-medical-video-recorder img {display:block !important;max-width:100% !important;height:auto !important;object-fit:contain;margin:0 auto;float:none !important;}\n#nv-teac-ur-4md-full-hd-medical-video-recorder .nv-hero img {width:100% !important;max-width:860px !important;}\n#nv-teac-ur-4md-full-hd-medical-video-recorder figcaption {font-size:14px;line-height:1.5;color:#526270;margin:12px 0 0;text-align:center;}\n#nv-teac-ur-4md-full-hd-medical-video-recorder .nv-visual-grid {display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:18px;width:100%;max-width:100%;}\n#nv-teac-ur-4md-full-hd-medical-video-recorder .nv-visual-grid figure {margin:0;display:flex;flex-direction:column;justify-content:center;}\n#nv-teac-ur-4md-full-hd-medical-video-recorder a {color:#1c5575;text-decoration:underline;}\n\n@media(max-width:640px){#nv-teac-ur-4md-full-hd-medical-video-recorder .nv-visual-grid {grid-template-columns:minmax(0,1fr);}#nv-teac-ur-4md-full-hd-medical-video-recorder figure {padding:12px;}}\n\u003c\/style\u003e\n\u003cdiv id=\"nv-teac-ur-4md-full-hd-medical-video-recorder\" style=\"width:100%;max-width:1000px;margin:0 auto;float:none;clear:both;box-sizing:border-box;\"\u003e\n\u003csection class=\"nv-intro\"\u003e\u003ch2\u003eTEAC UR-4MD Full HD Medical Video Recorder\u003c\/h2\u003e\n\u003cp\u003eUR-4MD Full HD medical video recorder with a 500 GB internal drive, 3.5 inch LCD, simultaneous internal\/USB recording and an optional DICOM gateway upgrade.\u003c\/p\u003e\n\u003cp\u003eThe TEAC UR-4MD records surgical video and still images with automatic signal and resolution detection. Internal storage and USB recording support documentation workflows, with network file transfer available through FTP or CIFS. DICOM\/PACS integration requires the appropriate optional upgrade and configuration.\u003c\/p\u003e\u003c\/section\u003e\u003cfigure class=\"nv-hero\"\u003e\u003cimg src=\"https:\/\/vimex-endoscopy.com\/wp-content\/uploads\/2022\/03\/thumbnail_1188668_720x460.jpg\" alt=\"TEAC UR-4MD medical video recorder front view\" width=\"720\" height=\"399\" style=\"display:block;max-width:100%;height:auto;margin:0 auto;\" decoding=\"async\"\u003e\u003cfigcaption\u003eTEAC UR-4MD recorder. On-screen clinical imagery is illustrative; the built-in LCD is not for diagnosis.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003csection\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\n\u003cdiv class=\"nv-grid\"\u003e\n\u003cdiv class=\"nv-card\"\u003e\n\u003ch3\u003eFull HD recording\u003c\/h3\u003e\n\u003cp\u003eRecords video and still images at up to 1920 × 1080. Manufacturer FAQ lists 30 \/ 29.97 Hz recording for Full HD.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"nv-card\"\u003e\n\u003ch3\u003eInternal and USB storage\u003c\/h3\u003e\n\u003cp\u003eA 500 GB internal hard drive is included. Simultaneous recording to internal and compatible external USB media is supported.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"nv-card\"\u003e\n\u003ch3\u003eBuilt-in display\u003c\/h3\u003e\n\u003cp\u003eA 3.5 inch colour LCD supports live view, playback and navigation. The supplier states that this display is not for diagnosis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"nv-card\"\u003e\n\u003ch3\u003eNetwork file transfer\u003c\/h3\u003e\n\u003cp\u003eRJ-45 Ethernet supports FTP and CIFS background file transfer to a configured network destination.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"nv-card\"\u003e\n\u003ch3\u003eOptional DICOM gateway\u003c\/h3\u003e\n\u003cp\u003eAn optional upgrade provides DICOM still-image storage and Modality Worklist support. PACS connectivity is not included automatically.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"nv-card\"\u003e\n\u003ch3\u003eOptional external controls\u003c\/h3\u003e\n\u003cp\u003eRemote control, footswitch, keyboard and barcode\/card reader functions require the appropriate optional devices.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eRecorder and interface illustrations\u003c\/h2\u003e\n\u003cdiv class=\"nv-visual-grid\"\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/vimex-endoscopy.com\/wp-content\/uploads\/2022\/02\/zdjecia-1-e1649660997660.png\" alt=\"TEAC UR-4MD medical recorder angled view\" width=\"450\" height=\"200\" style=\"display:block;max-width:100%;height:auto;margin:0 auto;\" loading=\"lazy\" decoding=\"async\"\u003e\u003cfigcaption\u003eUR-4MD control panel and built-in LCD, showing an illustrative menu.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/vimex-endoscopy.com\/wp-content\/uploads\/2022\/02\/obrazy-e1649661729952.png\" alt=\"TEAC UR-4MD manufacturer example interface screens\" width=\"500\" height=\"228\" style=\"display:block;max-width:100%;height:auto;margin:0 auto;\" loading=\"lazy\" decoding=\"async\"\u003e\u003cfigcaption\u003eManufacturer interface examples. Displayed images and data are illustrations; required options must be confirmed.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003cfigure\u003e\u003cimg src=\"https:\/\/vimex-endoscopy.com\/wp-content\/uploads\/2022\/02\/rozdz-e1649662623540.png\" alt=\"TEAC UR-4MD example image-sharing arrangement\" width=\"600\" height=\"199\" style=\"display:block;max-width:100%;height:auto;margin:0 auto;\" loading=\"lazy\" decoding=\"async\"\u003e\u003cfigcaption\u003eIllustrative sharing arrangement. External displays, mobile devices and network infrastructure are separate.\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cp\u003eManufacturer illustrations show the recorder, example interface screens and a sharing setup. Screens and external displays are illustrative. Check the options and network configuration included in the quoted unit.\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eRecording and storage specifications\u003c\/h2\u003e\n\u003cdiv class=\"nv-table-wrap\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel \/ manufacturer\u003c\/th\u003e\n\u003ctd\u003eUR-4MD \/ TEAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum Full HD recording\u003c\/th\u003e\n\u003ctd\u003e1920 × 1080; manufacturer FAQ lists 30 \/ 29.97 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBuilt-in LCD\u003c\/th\u003e\n\u003ctd\u003e3.5 inch colour; live view, playback and navigation; not for diagnosis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInternal drive\u003c\/th\u003e\n\u003ctd\u003e500 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExternal recording devices\u003c\/th\u003e\n\u003ctd\u003eCompatible USB flash drives and USB hard drives\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStill-image format\u003c\/th\u003e\n\u003ctd\u003eJPEG; DICOM still-image support with the applicable DICOM configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVideo format\u003c\/th\u003e\n\u003ctd\u003eMPEG-4 AVC\/H.264, MOV file container\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRecording media format\u003c\/th\u003e\n\u003ctd\u003eFAT32, manufacturer FAQ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApproximate Full HD recording times\u003c\/th\u003e\n\u003ctd\u003e90 h at 12 Mbit\/s; 60 h at 18 Mbit\/s; 45 h at 24 Mbit\/s, on the 500 GB drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNetwork\u003c\/th\u003e\n\u003ctd\u003eRJ-45 10\/100\/1000 Ethernet; FTP\/CIFS file transfer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDICOM\/PACS\u003c\/th\u003e\n\u003ctd\u003eOptional gateway upgrade; Modality Worklist and DICOM still-image storage; confirm licence and integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eConnections\u003c\/h2\u003e\n\u003cdiv class=\"nv-table-wrap\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVideo inputs\u003c\/th\u003e\n\u003ctd\u003e1 × SDI (BNC); 1 × single-link DVI; 1 × S-Video; 1 × composite video (BNC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSDI formats\u003c\/th\u003e\n\u003ctd\u003e3G\/HD-SDI 1080p \/ 1080i \/ 720p; SD-SDI 480i \/ 576i, manufacturer specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDVI input\/output formats\u003c\/th\u003e\n\u003ctd\u003e640 × 480 to 1920 × 1200; input support does not mean recording at 1920 × 1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVideo outputs\u003c\/th\u003e\n\u003ctd\u003e1 × SDI; 1 × DVI; 1 × S-Video; 1 × composite; additional SDI Thru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAudio inputs\u003c\/th\u003e\n\u003ctd\u003eEmbedded SDI audio; 2 stereo mini-jack inputs for line and microphone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAudio outputs\u003c\/th\u003e\n\u003ctd\u003eEmbedded SDI audio; 1 stereo mini-jack line output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUSB Type A\u003c\/th\u003e\n\u003ctd\u003e3 × USB 2.0: two front recording-device connectors and one rear optional-accessory connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUSB Type B\u003c\/th\u003e\n\u003ctd\u003e1 × USB 2.0 rear connector for access to the internal drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExternal triggers\u003c\/th\u003e\n\u003ctd\u003e3 stereo mini-jack connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHDMI\u003c\/th\u003e\n\u003ctd\u003eNo native HDMI connector; confirm a compatible HDMI-to-DVI adapter if required. TEAC notes that HDMI audio is not supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003ePhysical and electrical specifications\u003c\/h2\u003e\n\u003cdiv class=\"nv-table-wrap\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMains input\u003c\/th\u003e\n\u003ctd\u003e100–240 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions, W × D × H\u003c\/th\u003e\n\u003ctd\u003eApproximately 210.5 × 235 × 88.5 mm, current TEAC specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNet equipment weight\u003c\/th\u003e\n\u003ctd\u003eApproximately 2.6 kg; not a shipping weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e5–40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e−20 to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating humidity\u003c\/th\u003e\n\u003ctd\u003e5–80%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOptional accessories\u003c\/th\u003e\n\u003ctd\u003eRemote control, footswitch, keyboard, barcode\/card reader; confirm exact compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower-loss handling\u003c\/th\u003e\n\u003ctd\u003eManufacturer describes fail-safe saving and shutdown; follow the operating instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eConfiguration and supplied components\u003c\/h2\u003e\n\u003cp\u003eOne UR-4MD recorder with power cord and owner’s manual as listed by TEAC. Confirm all signal cables, optional controls, storage media and the DICOM upgrade in the quotation. External monitors, tablets, network storage and PACS\/HIS\/RIS systems pictured in illustrations are separate.\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eHandling and compatibility\u003c\/h2\u003e\n\u003cp\u003eConfirm camera output, connector, resolution and frame rate before ordering. Check the required DICOM licence, PACS\/worklist compatibility and network setup with the responsible IT team. The built-in LCD is for operation and review, not diagnosis. Follow the manufacturer instructions for closing recordings, removing media and maintaining reliable storage.\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eOrdering information\u003c\/h2\u003e\n\u003cp\u003eProvide the product reference or range, quantity, delivery location and intended use. Specify the required model, configuration, accessories and consumables, existing equipment to be integrated, and any installation, commissioning, training or maintenance requirements. For configurable ranges, confirm the exact manufacturer references before ordering.\u003c\/p\u003e\u003c\/section\u003e\u003csection class=\"nv-contact\"\u003e\u003ch2\u003eDelivery, spares and service\u003c\/h2\u003e\n\u003cp\u003eContact Nass Ventures for pricing, availability, delivery arrangements, compatible spares and consumables, installation and after-sales support. The quotation will confirm the final supplied configuration, documentation, warranty terms and service arrangements.\u003c\/p\u003e\u003c\/section\u003e\n\u003c\/div\u003e\n\u003c!-- SOURCE REVIEW: Uploaded supplier source https:\/\/vimex-endoscopy.com\/produkt\/nagrywarka\/. Supporting manufacturer documents: https:\/\/vimex-endoscopy.com\/wp-content\/uploads\/2022\/02\/en-ur-4md-brochure-dicom.pdf; https:\/\/teac.eu\/en\/products\/medical-image-recorder\/ur-4md\/specifications; https:\/\/teac.eu\/en\/products\/medical-image-recorder\/ur-4md\/faq; https:\/\/teac.eu\/en\/products\/medical-image-recorder\/ur-4md\/overview. DICOM is an optional upgrade in the linked TEAC brochure and current TEAC overview; manufacturer FAQ limits DICOM file support to still images. No DICOM video storage, included licence, cloud service or native HDMI claim. Simultaneous internal\/USB recording and FTP\/CIFS background transfer distinguished. Current TEAC dimensions 210.5×235×88.5 mm used; linked 2020 brochure rounds to 211×235×89 mm. Current box list gives power cord and manual; older brochure also mentions cable clamp, not promised here. LCD not for diagnosis retained. MPN is UR-4MD; no unverified barcode or warranty imported. No confirmed net price supplied; all Price, Cost per item and Compare-at price fields are blank. Unknown inventory, barcodes, condition and shipping weights are blank. --\u003e\n\u003c!-- IMAGE REVIEW: 4 original source-provided product\/feature image URLs verified with HTTP 200 and visually reviewed on 15 October 2026. Navigation, logos and unrelated cross-sell images excluded. Responsive description figures use the same verified images as the gallery. Images show illustrative configurations, not guaranteed package contents. External manufacturer-hosted description URLs are not rewritten to Shopify-hosted URLs by this CSV. --\u003e","brand":"TEAC","offers":[{"title":"Default Title","offer_id":64893518152057,"sku":"UR-4MD","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6977\/8041\/files\/thumbnail_1188668_720x460_a5d256ce-cdae-4ec4-ba05-ea46064c1306.jpg?v=1792063393","url":"https:\/\/www.nassventures-africa.com\/products\/teac-ur-4md-full-hd-medical-video-recorder","provider":"My Store","version":"1.0","type":"link"}