{"product_id":"usbeck-teclubrenner-din-double-lever-economy-flame-air-regulation","title":"Usbeck Teclubrenner, DIN, double lever, economy flame, air regulation","description":"\u003carticle\u003e\n\n\u003ch2\u003eUsbeck Teclubrenner, DIN, double lever, pilot flame, air regulation\u003c\/h2\u003e\n\n\u003cp\u003eThe Usbeck Teclub burner has been specially designed for demanding laboratory applications and offers excellent controllability thanks to its double lever, pilot flame and precise air regulation. Compared to conventional laboratory gas burners, this burner impresses with its standard-compliant design in accordance with DIN 30665 and its robust construction, which ensures a long service life even with intensive use.\u003c\/p\u003e\n\n\u003cp\u003eVersatile functions for professional laboratory use\u003c\/p\u003e\n\n\u003cp\u003eThis Teclub torch offers several advantages for use in laboratories, research facilities and specialist workshops. Its conically widened tube ensures an optimised air supply, which can be finely adjusted using a threaded regulating disc. This allows the gas\/air mixture to be precisely adjusted so that controlled and efficient combustion is achieved. When the gas tap is closed, a small flame remains, which complies with standardised safety standards.\u003c\/p\u003e\n\n\u003cp\u003eWith a height of 155 mm and a tube diameter of 14 mm, the burner is easy to integrate into typical laboratory set-ups. The double lever makes it easy to switch quickly between normal and pilot flame, while the regular air supply can be permanently adapted to different gases and flame requirements using the adjustable regulating disc. This means the burner can be used optimally for experiments, heating processes or sterilisation tasks in everyday laboratory work.\u003c\/p\u003e\n\n\u003ch3\u003eImportant technical details\u003c\/h3\u003e\n\n\u003cp\u003e- Suitable for natural gas and propane gas\u003cbr\u003e\n- Reaches up to 1500 °C (natural gas) or 1540 °C (propane gas)\u003cbr\u003e\n- Consumption of approx. 100 l\/h (natural gas) or 60 l\/h (propane gas)\u003cbr\u003e\n- Load between 1.25 kW and 1.5 kW depending on the type of gas\u003cbr\u003e\n- Weight of 270 g, making it easy to handle\u003cbr\u003e\n- Head diameter 17 mm for targeted and stable flame\u003cbr\u003e\n- Adhesive base optionally available\u003c\/p\u003e\n\n\u003cp\u003eIn addition, the burner complies with DIN 30665 and bears the DIN-DVGW reg. no. NG-2211AN0133. These certifications confirm the high safety and quality of the burner, meaning that it fulfils the demanding requirements of laboratories and research facilities. Thanks to its robust design, it is ideal for continuous operation and is characterised by particularly safe handling: The pilot flame continues to burn when the local gas tap is closed to prevent it from going out unexpectedly. Only the central shut-off switches off the gas supply for good.\u003c\/p\u003e\n\n\u003ch2\u003eConcrete areas of application\u003c\/h2\u003e\n\n\u003cp\u003eThe burner proves to be extremely useful in many areas:\n- Heating test tubes and flasks in chemical laboratories\u003cbr\u003e\n- Sterilisation of instruments such as pipette tips or inoculation loops in microbiological applications\u003cbr\u003e\n- Carrying out flame samples, especially when analysing alkali and alkaline earth salts\u003cbr\u003e\n- Rapid heating of solvents or samples in pharmaceutical laboratories\u003c\/p\u003e\n\n\u003cp\u003eIn addition, powdery or solid substances such as metal salts and organic compounds can be safely heated or incinerated to check various chemical reaction processes. Its high flame stability facilitates precise dosing of the heat supply, which is crucial for reproducible results in demanding experimental setups.\u003c\/p\u003e\n\n\u003cp\u003eFAQs\u003c\/p\u003e\n\n\u003ch3\u003eHow does the double lever operation work?\u003c\/h3\u003e\n\n\u003cp\u003eThe first lever is used to switch on and fine-tune the main input, while the second lever quickly switches to an economy flame. This means that changing work steps can be carried out without time-consuming re-ignition.\u003c\/p\u003e\n\n\u003cp\u003eWhich gases can be used\u003c\/p\u003e\n\n\u003cp\u003eThe burner is designed for both natural gas and propane gas. Thanks to its adjustable air supply, the gas\/air mixture can be optimally regulated for both fuels.\u003c\/p\u003e\n\n\u003ch3\u003eHow to clean the burner optimally\u003c\/h3\u003e\n\n\u003cp\u003eIt is advisable to dismantle the burner pipe at regular intervals and remove any deposits. Brushes with soft bristles and compressed air can be used for fine spots. In case of heavy soiling, a mild cleaning agent should also be used, which is then rinsed off without leaving any residue.\u003c\/p\u003e\n\n\u003cp\u003eWhat needs to be considered in terms of safety\u003c\/p\u003e\n\n\u003cp\u003eBecause of the DIN standard, a small flame continues to burn when the gas tap is closed. Therefore, the central shut-off of the laboratory should always be closed after use. Also ensure safe positioning to avoid burns or damage to laboratory benches.\u003c\/p\u003e\n\n\u003cp\u003eCan the flame intensity be precisely regulated?\u003c\/p\u003e\n\n\u003cp\u003eYes, the ratio of gas to air can be precisely adjusted using the air control disc, which ensures a stable and easily controllable flame.\u003c\/p\u003e\n\n\u003ch2\u003eConclusion\u003c\/h2\u003e\n\n\u003cp\u003eIn many laboratory environments, this DIN-compliant Teclub burner is a reliable standard for safe and efficient heating. Its sophisticated double-lever system enables quick switching between normal and pilot flame, while the precise air regulation ensures a controlled burning performance at all times. Its robust construction and precise adjustment options make it ideal for continuous use. In addition, certified quality standards such as DIN 30665 and DIN-DVGW reg. no. NG-2211AN0133 guarantee a high degree of safety and reliability. Anyone who places great value on quality and convenience will find this burner to be an excellent solution for everyday professional laboratory use.\u003c\/p\u003e\n\n\u003ctable\u003e\u003ctbody\u003e\n                                                            \u003ctr\u003e\n                            \u003ctd\u003e\n                                Construction (gas burner):\n\n                            \u003c\/td\u003e\n                             \u003ctd\u003e\nBunsen burnerTeclu burner\n                            \u003c\/td\u003e\n                        \u003c\/tr\u003e\n                                            \u003ctr\u003e\n                            \u003ctd\u003e\n                                Flame temperature:\n\n                            \u003c\/td\u003e\n                             \u003ctd\u003e\nNatural gas 1500?°CPropane gas 1540?°C\n                            \u003c\/td\u003e\n                        \u003c\/tr\u003e\n                                            \u003ctr\u003e\n                            \u003ctd\u003e\n                                Gas types:\n\n                            \u003c\/td\u003e\n                             \u003ctd\u003e\nnatural gaspropane\n                            \u003c\/td\u003e\n                        \u003c\/tr\u003e\n                                            \u003ctr\u003e\n                            \u003ctd\u003e\n                                Weight:\n\n                            \u003c\/td\u003e\n                             \u003ctd\u003e\n270 g\n                            \u003c\/td\u003e\n                        \u003c\/tr\u003e\n                                            \u003ctr\u003e\n                            \u003ctd\u003e\n                                Height (gas burner):\n\n                            \u003c\/td\u003e\n                             \u003ctd\u003e\n155 mm\n                            \u003c\/td\u003e\n                        \u003c\/tr\u003e\n                                            \u003ctr\u003e\n                            \u003ctd\u003e\n                                kW:\n\n                            \u003c\/td\u003e\n                             \u003ctd\u003e\n1,251,5\n                            \u003c\/td\u003e\n                        \u003c\/tr\u003e\n                                            \u003ctr\u003e\n                            \u003ctd\u003e\n                                Standards (gas burner):\n\n                            \u003c\/td\u003e\n                             \u003ctd\u003e\nDIN 30665DIN-DVGW-Reg.-Nr. NG-2211AN0133\n                            \u003c\/td\u003e\n                        \u003c\/tr\u003e\n                    \n                \n                                    \u003ctr\u003e\n                        \u003ctd\u003eShipping weight: \u003c\/td\u003e\n                        \u003ctd\u003e1,27 Kg\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                \n                                    \u003ctr\u003e\n                        \u003ctd\u003eProduct weight: \u003c\/td\u003e\n                        \u003ctd\u003e0,27 Kg\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                \n                \n                \n                                    \n                            \u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003c\/article\u003e","brand":"Made in Germany","offers":[{"title":"Default Title","offer_id":56328595079545,"sku":"USB_25014","price":187900.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6977\/8041\/files\/en-laboratory-gas-burner-bunsen-burner-usbeck-teclubrenner-din-double-lever-economy-flame-air-regulation.jpg?v=1765186941","url":"https:\/\/www.nassventures-africa.com\/products\/usbeck-teclubrenner-din-double-lever-economy-flame-air-regulation","provider":"My Store","version":"1.0","type":"link"}