Range:
Total Cholesterol: 100-400 mg/dL (2.59-10.36 mmol/L)
HDL Cholesterol: 15-100 mg/dL (0.39-2.59 mmol/L)
Glucose: 20-600 mg/dL (1.11-3.33 mmol/L) -
Time:
about 2 minutes
-
Sample:
40 µL whole blood (fingerstick or venous)
-
Analyzer:
CardioChek PA only
-
CLIA:
Waived
Filter
Best Seller
-
Vacutainer Blood Transfer D...
₦497,400.00 -
Glucometer Test Strips x 50...
₦51,400.00 -
Glucorx Nexus Strips - 50 S...
₦48,200.00 -
Cholesterol Strips for Card...
₦369,000.00 -
BD Vacutainer EST Plus Citr...
₦48,200.00 -
Suresign D-Dimer Test Casse...
₦343,400.00 -
Accu-Chek Instant 50 strips...
₦32,100.00 -
CoaguChek INRange Meter
₦1,444,000.00 -
Suresign Finecare Nt-proBNP...
₦698,000.00 -
Suresign Professional D-dim...
₦74,200.00
Blood Testing
PTS DiagnosticsTM Capillary Tubes provide significant savings over traditional transfer tube technology. Using a single glass tube with plastic casing, the PTS Diagnostics Capillary Tubes provide consistent self-wicking technology to preset volumes. This improved design is ideal for all blood collection needs.
BD Vacutainer 4ml glucose analysis tubes are used to preserve blood samples for glucose and lactate determination. Glucose values, in blood samples that are unpreserved, rapidly decrease after being collected. The 4ml glucose analysis tubes contain Sodium Fluoride and Potassium Oxalate as additives to stop glucose values from decreasing after the samples have been collected.
- Volume: 4ml
- Size: 13mm x 75mm
- Grey Hemogard cap
- Pack of 100
- Ref: 368921
BD Vacutainer PST II Tubes are used to separate a plasma sample. They contain Lithium Heparin to prevent coagulation an acrylic gel that forms a barrier between the cells and plasma during centrifugation. Available in sizes 3ml, 4.5ml, 8ml.
Specifications
- Additive: Lithium Heparin17IU/ml / Gel
- Cap colour: Light Green
- Label type: Block
- Volume: 3ml
- Size: 13mm x 75mm
- NHS Code: KFK130
BD Microtainer™ tubes are used for the collection, transport and processing of capillary or venous blood from skin puncture. It is ideal for use with infants, children, geriatrics and emergency patients whenever only the smallest amounts of blood are required.
- Wider diameter (8mm) for ease of collection and improved mixing
- Color-coded caps correspond to the standard Vacutainer™ color-coding system for easy identification
- Available with a variety of additives for use in various tests
- Amber-tinted tubes are available for light sensitive analytes
- Integrated collection scoop and visible fill lines
- Microgard™ “twist assist” closure reduces the risk of splatter when removing the cap to protect against exposure
- Closure can be used with a tube extender for use in 13mm x 75mm racks
BD Vacutainer Plasma Tubes contain Sodium or Lithium Heparin and are used to obtain a plasma sample. The tubes are are available in both plastic and glass, in sizes 2ml, 4ml and 6ml, and are identified with a green cap. The additive in the plastic plasma tube is spray coated onto the inner wall.
BD Vacutainer Heparin tubes can be centrifuged immediately after collection.
Specifications
- Additive: Sodium Heparin 17IU/ml
- Cap colour: Green
- Label type: Paper
- Volume: 6ml
- Size: 13mm x 100mm
- NHS Code: KFK279
The BD Microtainer® contact-activated lancet is a safety-engineered device used for the fingerstick collection of blood. Fingersticks should not be performed on children less than 1 year of age.
Features and Benefits:
- Ergonomic design: The lancet enhances user comfort with an ergonomic design for a more comfortable grip.
- Easier sampling: It activates only when positioned and pressed against the skin, facilitating a consistent puncture depth for easier sampling.
- Improved visibility: The lancet covers only a small area at the contact point, which improves the visibility of the desired puncture site.
- Intuitive procedure: The intuitive procedure reduces training time, and the design prevents product reuse, reducing the possibility of patient, clinician, and/or sample contamination.
- 17G x 2.0mm
BD Vacutainer EST Tubes - 3ml, 13x75mm, See Through, Qty 100
BD Vacutainer® ESTTM has no additives and is suitable as a secondary tube for anti-coagulated blood samples, for example for taking plasma samples from blood bags. The EST can also be used as a discard tube.
- Volume (ml) - 3
- Size (mm) - 13x75
- Material - PET
- Lable - See through
- Closure Cap - Hemogard
Looking to buy BD Vacutainer® Eclipse™ blood collection needle 21g x1.25 x100 (P)? Medisave currently has BD Vacutainer® Eclipse™ blood collection needle 21g x1.25 x100 (P) in stock, along with more from the brand Becton Dickinson and a range of other Injection Infusion products ready to order in just a few clicks. Discover Medisave's full range of Injection Infusion now.
Unistik® 3 single-use sterile safety lancets provide an easy and convenient way to perform capillary blood sampling.
A simple one-click action activates the lancet allowing the Health Care Professional to choose exactly when the lancet will activate. Unistik® 3 also features a clear alignment guide which means you can be certain where you place the lancet. Unistik® 3 means you stay in control of the sampling experience.
Independent clinical data¹ shows that Unistik® 3 safety lancets with Comfort Zone Technology® reduces pain, resulting in a more comfortable experience for the patient². Comfort Zone Technology® is comprised of eight raised pressure points on the patient end of the safety lancet. This patented technology sends a signal of comfort to the brain, helping to reduce the pain associated with the fingerstick.
The Unistik® 3 single-use safety lancet range offers a choice of five different depth and gauge specifications for use across all clinical environments and blood sampling requirements.
The Unistik® 3 Neonatal safety lancet is a puncture blade device designed for comfortable neonatal heel sampling¹.
Benefits:
- Control. Via an activation button and alignment guide.
- Comfort. Comfort Zone Technology® maximises comfort for the patient during the sampling procedure¹.
- Safety. Needle retracts immediately after use to reduce the risk of needlestick injuries.
- Safety. Lock out indicator prevents reuse.
Unistik®3 Comfort
- 28 gauge lancet 1.8mm
- Suggested test areas e.g. ward blood glucose monitoring and HbA1C
A lancet to suit all patients
The Unilet® range of lancets from Owen Mumford allows you to obtain the blood sample you need to manage your blood glucose.
The specially shaped needles and choice of needle sizes of the Unilet® range ensure you can obtain the right blood volume with less pain1.
Unilet® lancets have a universal design and are compatible with most capillary blood lancing devices.†
Benefits:
- Comfort. Provide a comfortable lancing experience without compromising on the blood volume 1
- Control. Offer a lancet designed for your needs that may make self management of treatment more comfortable
Unilet Eco
- A high quality entry-level lancet that provides a comfortable lancing experience without compromising on blood volume
Glucorx Glucose Control Solution For Nexus & Hct X1
The DCA HbA1C Normal/Abnormal control kit for use with the Siemens DCA Vantage Analyzer.
CLEARANCE - Short Dated 09/2024
Quality control solution for Cholesterol Test Strips. For use with the Roche Accutrend and Accutrend Plus.
Please note that the product supplied is the Control Solution only and not the testing device which can be purchased separately.
Quality control solution for Cholesterol Test Strips. For use with the Roche Accutrend and Accutrend Plus.
Please note that the product supplied is the Control Solution only and not the testing device which can be purchased separately.
The Accutrend cholesterol test strips are meant for use in blood cholesterol testing with the Accutrend Plus meter. Only a single drop of capillary blood is necessary to measure the cholesterol levels, which are ready within 180 seconds. The cholesterol test strips guarantee high measuring accuracy - they measure in a range of 150 - 300 mg/dl, respectively of 3.88 - 7.76 mmol/l.
One package contains 25 test strips and the corresponding code strip.
Accutrend Plus uses specially designed superior quality test strips. The test strips contain:
- a yellow protective mesh, impregnated with a surfactant (application field)
- a glass fiber fleece that works as a separating layer for blood cells
- a reaction film in which the color formation takes place and
- a bar code on the reverse side, which is read by the meter to confirm test strip identity, i.e. the lot number on the test strip is congruent with the stored code
Current expiry date 30/04/24.
30G On Call Extra lancets, designed to minimise pain. Box of 100 lancets.
Compatible with the On Call Extra lancing device, which comes free with the following meters:
- On Call Extra
- On Call Extra Mobile
- On Call Extra Voice
3 in 1 Combo Test Device for a complete Lipid Panel using whole blood, serum or plasma
- Total Cholesterol (CHOL)
- High Density Lipoprotein (HDL)
- Triglycerides (TRIG)
Also includes calculated tests
- Low Density Lipoprotein (LDL)
- CHOL/HDL ratio
Cardiac Risk Assessment
Safety-engineered lancet with 3 depth settings for different patient needs
Safe and easy to use, the ACCU-CHEK Safe-T-Pro Plus lancet device is designed to help you get the right amount of blood the first time.
The single-use lancet device has three depth settings – 1.3, 1.8, and 2.3mm – for varying patient conditions, such as poor circulation or calloused fingers. Healthcare professionals have the flexibility at the bedside to choose the optimal depth based on the patient condition and blood volume required.
The multiple depth settings may also enable a facility to reduce the number of items that need to be stocked in inventory, which can increase operational efficiency.
Enhanced patient care
- Three depth settings for varying patient types
- Thin, 23-gauge, silicone-coated needle with beveled tip for improved comfort
Safety-engineered
- OSHA-compliant – automatically retracts lancet after use
- Helps reduce accidental fingersticks
- Provides excellent infection control
Economic value
- May reduce number of lancets used
- Minimum training required
30ml Universal Plain Label Flow Seal Cap, 1 * 400 Items
- Manufactured from virgin, medical grade, polystyrene
- Ideal for general patient sample collection, storage and transport needs
- Fitted with leakproof flow seal cap and 95kPa compliant
- Supplied sterile by EtO
- Maximum rcf 2000 x g
- Convenient inner bags of 50 pieces within each case
- CE Marked in accordance with European Directive 98/79/EC
BD Vacutainer plastic SST II advance tube, yellow, 5ml 13x100
Rapid test for qualitative detection of d-dimer in whole blood, capillary blood or plasma specimens, and new: edta-blood and citrate blood!
- D-Dimer is a fibrin degradation product, a small protein fragment present in the blood after a blood clot is degraded by fibrinolysis.
- This test enables the preclusion of a pulmonary embolism, deep venous thrombosis or disseminated intravascular coagulation.
- Sensitivity: 500 ng/ml.
- Results after 10 minutes.
- Storage: 2 - 30 °C, do not freeze.
- Single dropper bottle for the buffer solution, so there is no possibility of transmission and there is sufficient reagents for each cassette.
Important Note: With patients that have acute chest pain and shortness of breath a higher D-Dimer value and the absence of typical cardiac marker changes indicate a pulmonary embolism.
- Easy to use
- No coding required
- Optimised so very little blood is needed to get an accurate reading.
- This Class IIa medical device fulfills the requirements of EN ISO 15197:2015 – the highest and most up-to-date standard of blood glucose testing in the UK.
PACK CONTAINS:
- 50x Test Strips
- Instruction manual
Accu-chek Performa T/strips
Features
• Easy to handle
• To be used with Accu-Chek Performa Nano Blood Glucose Meter
Solution to work with the Accu-Chek Instant blood glucose monitor.
The control solution contains a known amount of glucose, so you can simply use it instead of blood on a test strip. If the result matches the expected glucose level, you can be confident that your meter and test strips are working properly.
- Touchable strip has protected dosing area
- Designed to minimize potential of cross contamination
- Easy to sample especially in low light
- Dosing site architecture allows multiple sampling application angles
- "Y" shaped capillary window acts like a funnel to help draw blood into the strip quickly
- 5 Second measuring time for quick results
- Small blood sample of 0.6μl.
- AC and DC impulses to detect strips damaged by moisture and/or temperature
- Contacts detects scratched strips and can either compensate or reject them depending on electrical resistance
- Dedicated contacts signal the meter when there is enough blood in the strip to start measurement
- No under-sampling errors possible
- Box of 50