Miele laboratory washer PLW 8604
This compact and powerful cleaning solution is particularly suitable for laboratories that require reliable yet simple reprocessing of laboratory glassware. Equipped with a demineralised water connection, this appliance ensures particularly thorough final cleaning with demineralised water. Compared to similar alternatives, it scores points with its convenient touch display, modular loading system and networkability.
Performance features at a glance
This laboratory warewashing system is aimed at professional users in research, pharmacy and quality assurance who want to wash their glassware efficiently and safely. The most important features are:
- Space for up to 64 narrow-necked tubes per batch
- Flexible EasyLoad system for different types of bottles and jars
- M Touch Basic touch display for convenient operation
- High-quality stainless steel wash cabinet and powerful circulation pump (Qmax 500 l/min.)
- Short programme running times from 28 minutes
- Factory-integrated WiFi module for easy networking
- Dual water connection (cold water and demineralised water)
The appliance is also highly customisable: the modular loading and accessory concept allows different types of laboratory glassware - from test tubes and vials to larger laboratory bottles - to be cleaned simultaneously. Further inserts can be added to the upper basket to accommodate additional glassware. The integrated powder dosing unit in the door enables the precise addition of cleaning agents, while the built-in water softener optimises the process and ensures consistent rinsing quality.
The M Touch Basic control unit offers a clear text display, programmable functions as well as a remaining time display and programme sequence display. Six pre-installed programmes cover typical requirements - including cure programmes from 28 minutes, medium and long wash cycles, separate rinsing with cold or demineralised water - while four additional programme slots can be configured individually. The reliable waterproof system protects against water damage and guarantees maximum operational safety over the entire duration of use.
The appliance also boasts a robust design: a floor-standing appliance, suitable for under-counter installation and a slimline design, it fits flexibly into existing laboratory environments. With a net width of 598 mm and a usable height of 520 mm, there is sufficient space for demanding laboratory glassware. The appliance has also been tested for 15,000 operating hours and is therefore ideally equipped for long-term use.
Application examples
- Analytical laboratories: Efficient cleaning of test tubes, flasks or narrow-necked bottles, for example for pH measurements or HPLC samples
.
- Pharmaceutical industry: Thorough decontamination of vials used for sample preparation and sterile filling.
- Biotechnology: Preparation of cell culture bottles and media bottles for reproducible test results.
- Quality assurance in food industry laboratories: Cleaning of laboratory bottles in which ingredients such as proteins or lipids are analysed.
Certifications and standards
The device fulfils relevant safety and quality standards in the laboratory environment. Among other things, it bears the VDE mark for electrical safety, is protected to IP 21 and complies with important European standards such as EN 61010-1 and EN 61010-2-040. It also complies with the RoHS Directive 2011/65/EU, which indicates environmentally friendly use and conformity during production.
Frequently asked questions (FAQs)
How are process chemicals dosed?
- The integrated dosing option in the door facilitates the precise addition of detergents in powder form, while additional external dosing modules can be connected as an option.
Can the appliance rinse larger bottles safely?
- Yes, thanks to the EasyLoad system, laboratory bottles or flasks with narrow necks of up to 64 pieces per batch can also be cleaned efficiently.
How does networking via the integrated WiFi module work?
- The factory-installed WiFi communication module allows integration into compatible process documentation software; a network printer can also be used as an option.
What maintenance steps are required on a regular basis?
- As a rule, we recommend checking the filter unit and the salt container in the door. A visual inspection of seals and rinsing nozzles is also advisable in order to reliably achieve high levels of cleanliness.
Conclusion
This laboratory-specific cleaning system impresses with its high efficiency, consistent user-friendliness and comprehensive equipment. Thanks to modular loading options and variable wash programmes, it covers a wide range of laboratory activities. With networkable technology, a convenient touch display and robust design, it takes the strain off staff in everyday laboratory work and ensures the best cleaning results over many years of operation.
| Effective for: | glass |
| Filter: | multi-component filter system |
| Power (cleaning equipment): | 8,9 kW |
| Standards (cleaning equipment): | EN 60529: IP21EN 61010-1EN 61010-2-040RoHS Directive 2011/65/EUVDE mark (electrical safety) |
| Type Dust Extractors, Cleaning Devices: | Lab washercleaning and disinfecting machine |
| Shipping weight: | 77,00 Kg |
| Product weight: | 68,00 Kg |
| Dimensions: | × × cm |