Filter
Best Seller
Infant Incubator
Overview
The DIXION BabyGuard I-1120-2 Transformer is a three-in-one neonatal care system integrating incubation, first aid and monitoring functions for NICU use.
Product Notes
Fast switching and seamless care
Fast switching between infant incubator and radiant warmer modes by one click, providing a closed incubation environment for newborns, while also can be transformed into an open emergency space.
Applications
• Neonatology departments
• NICU and newborn intensive care areas
• Maternity and paediatric clinical settings
• Radiant warmer / open-care use
• Neonatal monitoring workflows depending on configuration
Technical Specifications
Control: 10.4 inch TFT color LCD touch screen
Electric tilting system: +
Temperature servo control: air mode, baby mode, kangaroo mode
Bassinet angle display function: +
Humidity control: +
Panel damping system: opt
Oxygen concentration control: +
Weighing system: opt
Skin temperature sensor: +
Video recording: opt
>37°C: +
Observation lamp: opt
Vertical height adjustment stand: +
Ambient temperature and humidity monitoring: opt
Hands-free alarm silence: +
Temperature overshoot in air control mode: No greater than 1.0 °
Temperature servo control mode: Pre-warm mode, Manual mode, Baby mode
Warmer module: +
APGAR, CPR: +
SpO2 monitoring: Hemoglobin monitoring
ECG monitoring: opt
CO2 monitoring: opt
Ordering Information
• Please confirm the required model, quantity, delivery location and clinical department before ordering.
• Confirm accessories, optional configurations, installation requirements and local regulatory requirements before purchase.
• For hospital projects, Nass Ventures can support sourcing, procurement and equipment planning depending on the final configuration.
Overview
The DIXION BabyGuard I-1120 Transformer combines closed infant incubator mode, open radiant warmer mode and neonatal monitoring functions for hospital neonatal care.
Applications
• Neonatology departments
• NICU and newborn intensive care areas
• Maternity and paediatric clinical settings
• Radiant warmer / open-care use
• Neonatal monitoring workflows depending on configuration
Technical Specifications
Mode of control: Air mode and Baby mode controlled by micro-computer
Air temperature control range: 20°C-37°C(override mode 37°C-39°C)
Baby temperature control range: 34°C-37°C(override mode 37°C-38°C)
Accuracy of skin temperature sensor: within ± 0.2°C
The temperature fluctuation between incubator temperature and average incubator temperature (under stable temperature condition): ≤0.5°C
Temperature uniformity: ≤0.8°C(mattress is on the horizontal position) ≤1.0°C(mattress is on the maximum tilt position)
Inclination of the bassinet: ± 12° (stepless adjustable)
Noise inside hood (stable working condition): ≤50dB(A)
Relative Humidity Level: Humidity display range Humidity control range Accuracy of humidity display Accuracy of humidity control: 0%RH~100%RH 0%RH~90%RH ± 5%RH ± 5%R
Oxygen Level: Indication range of oxygen concentration Control range of oxygen concentration Indication accuracy of oxygen concentration Control accuracy of oxygen concentration: 0%~100% 20%~60% ± 2% (The set value is below 25%) ± 3% (The set value is above 25%) ±4% 02
Control Mode: Pre-warm mode, manual mode and baby mode are controlled by micro-computer
Baby mode temperature control range: 34°C-38°C
Control accuracy ( The fluctuation range between Skin temperature and Set temperature): ≤0.5°C
Temperature uniformity of mattress: ≤2°C
SPO2 Display range: 1- 100%
SPO2 Display resolution: 1%
SPO2 Alarm setting range: Upper limit:50 ~100% Lower limit: 45-95%
PR Display range: 25-240 bpm
PR Display resolution: 1bpm
PR Alarm Setting range: Upper limit: 80 – 240 bpm Lower limit: 35-180 bpm
PI Display range: 0.02-20.0%
PI Display Resolution: 0.01%
Ordering Information
• Please confirm the required model, quantity, delivery location and clinical department before ordering.
• Confirm accessories, optional configurations, installation requirements and local regulatory requirements before purchase.
• For hospital projects, Nass Ventures can support sourcing, procurement and equipment planning depending on the final configuration.
Overview
The DIXION BabyGuard I-1125 is a transport infant incubator designed for intensive care and neonatal transportation, including use in neonatology departments and ambulances depending on configuration.
Product Notes
Infant Incubator Babyguard I-1125 (Transport) with computer controlled air-temp/skin-temp
system is equipped with built-in battery, that allows using it in neonatology department as well
Applications
• Neonatology departments
• NICU and newborn intensive care areas
• Maternity and paediatric clinical settings
• Ambulance or in-hospital neonatal transport depending on configuration
Key Features
• Mode of control: Air mode and Baby mode controlled by micro-computer
• AC/DC power alternatively
• Multiple failure alarm indication
• Passive air humidification in the chamber
• Double-walled hood (acrylic-glass) with side door(so that the bassinet can be pulled out from it)
• The height of the unit is adjustable
• Oxygen supply system
• Observation lamp
• Set temp/Air temp/Baby temp/battery capacity
• can be displayed separately
• >37°C temperature set function (optional)
• Main Body (Hood, Controller, Bassinet, Internal battery,Observation lamp)
• Oxygen Cylinders
• Skin temperature sensor
• I.V. Pole
• Mattress
• Adjustable stand
• 37°C override temperature mode
Ordering Information
• Please confirm the required model, quantity, delivery location and clinical department before ordering.
• Confirm accessories, optional configurations, installation requirements and local regulatory requirements before purchase.
• For hospital projects, Nass Ventures can support sourcing, procurement and equipment planning depending on the final configuration.
Overview
Infant incubator BabyGuard 1-1120 for intensive care is air-temp, skin-temp, air humidity and oxygen concentration servo-controlled by a micro-computer. Its graphic display represents all trends, which allows the doctor to make ‘at-a-glance’ assessment of the environment inside the incubator. The infant incubator is equipped with a special air circulation system inside the apparatus which minimizes the flow in the hood environment. The automatic curtain reduces the heat loss. The double-walled hood conserves the heat for 2 hours.
Applications
• Neonatology departments
• NICU and newborn intensive care areas
• Maternity and paediatric clinical settings
Key Features
• Air temperature and skin temperature servo-control
• Air humidity servo-control
• Oxygen concentration servo-control (optional)
• Double-walled hood
• Basic stand on wheels and with brakes
• Built-in weigh scales (optional)
• 3 drawers for belongings and shelves for additional equipment
• IV stand
• Side windows of the chamber are equipped with transparent leaves and flexible sleeves.
• Front access window with iris diaphragm
• Smooth bassinet adjustment
• X-ray film cassette
• Electronic control
• Film control keyboard
• Large LCD display reflects real skin and air temperature, set air temperature, heating, graphic trends (up to 48 hours)
• 9-alarm option
• RS-232 interface for distance control
• Vertical height adjustment stand
Technical Specifications
Air temperature control range: 25 – 37 °C (temperature override mode to 37 – 39 °C)
Skin temperature control range: 34 – 37 °C (temperature override mode to 37 – 38 °C)
Temperature rise time: 40 min
Humidity control range: 0 – 90 %
Water container capacity: 1.2 l
1 container hour of service: up to 12 hours
Oxygen concentration measuring range: 0 – 99 %
Oxygen concentration control range: 20 – 60 %
Inclination of the bassinet: ± 8°
Air movement rate (inside the hood): < 0.2 m/s
Noise level (inside the hood): ≤ 45 dB
Alarms: Power failure Airflow failure Air temperature sensor failure Skin temperature sensor failure Temperature sensor deviation High temperature sensor failure High or low skin temperature High or low humidity level High or low oxygen concentration level
Power supply: 220 – 230 V, 50 – 60 Hz
Dimension: 1110mm×710mm×888mm (Main body) 1029mm×697mm×826mm (Cabinet)
Gross Weight: 70kg (Main Body) 80kg (Cabinet)
Ordering Information
• Please confirm the required model, quantity, delivery location and clinical department before ordering.
• Confirm accessories, optional configurations, installation requirements and local regulatory requirements before purchase.
• For hospital projects, Nass Ventures can support sourcing, procurement and equipment planning depending on the final configuration.
Overview
Infant incubator BabyGuard I-1107 for intensive care is air-temp, skin-temp, air humidity and oxygen concentration (optional) servo-controlled by a micro-computer and equipped with a special air circulation system inside the apparatus which minimizes the flow in the hood environment. The automatic curtain reduces the heat loss. The double-walled hood conserves the heat for 2 hours.
Applications
• Neonatology departments
• NICU and newborn intensive care areas
• Maternity and paediatric clinical settings
Key Features
• Air temperature and skin temperature servo-control
• Air humidity servo-control
• Oxygen concentration display system
• Double-walled hood
• Basic stand on wheels and with brakes
• Weigh scales (optional)
• 3 drawers
• Side windows of the chamber are equipped with transparent leaves and flexible sleeves.
• Front access window with iris diaphragm
• Smooth couch adjustment
• Film control keyboard
• LED indicators reflect real temperature of skin and air, set temperature of air, heating
• 9-alarm option
• RS-232 interface for distance control
Technical Specifications
Air temperature control range: 25 – 37 °C (temperature override mode to 37 – 39 °C)
Skin temperature control range: 34 – 37 °C (temperature override mode to 37 – 38 °C)
Temperature rise time: 30 min
Humidity control range: 0 – 90 %
Indicator range of oxygen concentration: 0 – 99 %
Inclination of the bassinet: ± 12°
Airflow rate within hood environment: < 0,3 m/s
Noise level (inside the hood): ≤ 45 dB
Alarms: Power failure Airflow failure Air temperature sensor failure Skin temperature sensor failure Temperature sensor deviation High temperature sensor failure High or low skin temperature High or low humidity level High or low oxygen concentration level
Power supply: 220 – 230 V, 50 – 60 Hz
Dimension: 1085mm×640mm×915mm (Main body) 1125mm×665mm×730mm (Cabinet)
Gross weight: 68kg 60kg (Cabinet)
Ordering Information
• Please confirm the required model, quantity, delivery location and clinical department before ordering.
• Confirm accessories, optional configurations, installation requirements and local regulatory requirements before purchase.
• For hospital projects, Nass Ventures can support sourcing, procurement and equipment planning depending on the final configuration.
Overview
The DIXION BabyGuard I-1103 is an infant incubator for neonatal intensive care. It provides air-temperature and skin-temperature servo control by micro-computer and uses an internal air-circulation system designed to minimise airflow inside the hood environment. The automatic curtain helps reduce heat loss, while the double-walled hood helps conserve heat.
Applications
• Neonatal intensive care
• Infant warming and incubation
• Hospital neonatology departments
• Paediatric and maternity clinical settings
Key Features
• Air mode and Baby mode controlled by micro-computer
• Passive air humidification in the chamber
• Double-walled hood
• Basic stand on wheels with brakes
• Optional weighing scales
• Three drawers
• Side chamber windows with transparent flexible sleeves
• Front access window with iris diaphragm
• Smooth bassinet adjustment
• Film touchpad control
• LED indicators for real skin temperature, real air temperature, set air temperature and heating status
• 7-alarm system
• RS-232 interface for distance control
Technical Specifications
Temperature servo-control: Included
Air temperature control range: 25–37°C, override mode 37–39°C
Skin temperature control range: 34–37°C, override mode 37–38°C
Temperature rise time: 30 minutes
Bassinet inclination: ±12°
Airflow rate within hood environment: <0.3 m/sec
Noise level inside hood: ≤45 dB
Alarms: Power failure, airflow failure, air temperature sensor failure, skin temperature sensor failure, temperature sensor deviation, high temperature sensor failure and over-temperature alarm
Power supply: 220–230 V, 50–60 Hz
Main body dimensions: 1085 × 640 × 910 mm
Cabinet dimensions: 1125 × 665 × 725 mm
Gross weight: 63 kg main body; 68 kg cabinet
Ordering Information
• Please confirm the required model, quantity, delivery location and clinical department before ordering.
• Confirm accessories, cabinet/stand requirements, optional weighing scale, installation requirements and local regulatory requirements before purchase.
• For hospital projects, Nass Ventures can support sourcing, procurement and equipment planning depending on the final configuration.
Overview
The Kartsana TG-1000 is a transport stretcher trolley designed for paediatric services and incubator transport applications. It is intended to support safe, controlled hospital movement where infant incubator compatibility and height adjustment are required.
Applications
• Paediatric patient transport
• Emergency transport
• Infant incubator transport
• Hospital and clinical transfer areas
Key Features
• Designed for use with infant incubators; please confirm incubator model compatibility before ordering
• Height-adjustable stretcher trolley for clinical transport applications
• Hydraulic and electric operation depending on configuration
• Hydraulic system unlocking button in case of fault
• Safety system designed to help avoid collapse
• Two locking wheels plus two wheels with brakes
• Single-pedal wheel unlocking for operator control
• Improved control panel for more intuitive operation
• Emergency lights for increased safety
• Two batteries to support operating autonomy
Technical Specifications
• Maximum load: 300 kg (661.39 lb)
• Length: 1,972 mm (78 in)
• Width: 574 mm (23 in)
• Height adjustment range: 350–1,300 mm (13.8–51.2 in)
• Wheel diameter: 160 mm (6.3 in)
• Patient type: paediatric
• Number of sections: 1-section
• Applications: transport, emergency, infant incubator use
Ordering Information
• Please confirm the required model, quantity, delivery location and clinical department before ordering.
• Confirm incubator compatibility, accessories, configuration, batteries, installation requirements and local regulatory requirements before purchase.
• For hospital projects, Nass Ventures can support sourcing, procurement and equipment planning depending on the final configuration.
Ertunç Özcan Magic Loggia Ultimate M Neonatal Incubator is a neonatal incubator designed for controlled temperature, humidity, oxygen-concentration and infant-access workflows.
Product Overview
The air circulation system ensures stable temperature control, uniform temperature distribution, humidification, effective isolation of the baby from airborne contaminants and control of oxygen concentrations. Access to the infant is provided by the entrance panels. When the entrance panel is open, warm air passes under the front edge of the cushion to the top of the entrance panel exit, minimizing the temperature drop in the canopy environment. The incubator is designed to be used under normal conditions at an ambient operating temperature of 20˚ to 30˚C. In Magic Loggia Ultimate M Model Baby Incubators, skin or air temperature control is selected by the control module.
Key Features
- 10.1” Touch TFT LCD display
- 80 cm x 40 cm Silinebilir ve Su Geçirmez Bebek Yatağı
- Multi-use skin temperature probe
- Antibacterial air microfilter
- X-Ray cassette tray
- Air curtain activated when the cabin door is opened
- Sterilizable/autoclavable humidification chamber
- Self-closing inlets for accessory use in the cabin
- Digital scales
- Height adjustment
- Aspiration unit
- Flowmeter unit
- Monitor shelf
- Serum holder Disposable skin temperature probe
- Skin temperature probe detection scale
- Servo controlled oxygen system
- 360º rotatable drawer (1/2/4 drawer options optional) (right and/or left side)
- 180º downward opening front and back cover
- Movable heating element
- Condensation system that transfers the water vapor formed inside the device under high temperature and humidity to a jar outside the system Special kangaroo mode that can be heated with the parent's body heat instead of an incubator Automatic Humidity Mode
- Comfort Zone Feature
- Sound and light alarm in case incubator lids are left open
Typical Clinical Use
- Neonatal intensive-care environments
- Newborn and premature infant thermal support
- Hospital neonatal wards and NICU workflows
- Clinical observation, access and care support depending on configuration
Ordering Information
Please contact Nass Ventures to confirm the required configuration, accessories, voltage, installation requirements, training, warranty, delivery and final quotation before ordering.
Important: This neonatal-care product should be selected, configured and used by trained healthcare professionals in appropriate clinical environments and in line with local clinical protocols.
Ertunç Özcan Baby Nest H-100 Transport Incubator is a neonatal transport incubator designed for safe transport of critical newborns under intensive-care conditions.
Product Overview
It is designed for the transport of critical newborns in safe and intensive care conditions.
Key Features
- Has double wall housing to reduce radiant heat loss
- It can work with 220 -230 V AC, 50/60 Hz. city network and 12 V DC and with its rechargeable internal battery
- Can work for 4 hours with its built-in battery
- There is an examination lamp on the incubator so that the baby can be observed comfortably in conditions where the lighting is insufficient.
- Passive humidification system prevents water spillage from the moisture container and minimizes the risk of contamination
- In-cab noise level less than 50 decibels
- Optionally transport ventilators can be added
Typical Clinical Use
- Neonatal intensive-care environments
- Newborn and premature infant thermal support
- Hospital neonatal wards and NICU workflows
- Clinical observation, access and care support depending on configuration
Ordering Information
Please contact Nass Ventures to confirm the required configuration, accessories, voltage, installation requirements, training, warranty, delivery and final quotation before ordering.
Important: This neonatal-care product should be selected, configured and used by trained healthcare professionals in appropriate clinical environments and in line with local clinical protocols.
Ertunç Özcan Magic Loggia Ultimate Neonatal Incubator is a neonatal incubator with a 10.1-inch touch TFT-LCD screen and advanced incubator monitoring features.
Product Overview
Magic Loggia Ultimate; With its user-friendly interface, scope and easy-to-use program content, it has a touch, color 10.1-inch TFT-LCD screen.
Key Features
- Smart display feature that allows air, skin, humidity / oxygen and balance values to be monitored remotely
- Cabin with double walls and large beds suitable for twin babies
- The raw material used in its design does not contain chemical dyes.
- Numerical and graphical trend record up to 32 days.
- It has a Servo-controlled humidity and oxygen system that reaches the set value quickly. (Humidity up to 95% and oxygen up to 85% can be adjusted.)
- 6 intervention windows that can be easily opened with elbow contact, X-Ray cassette tray, balance system between 1g and 10kg, sterilizable moisture module
- Double-walled cover system that can be opened 180° downwards at the front and/or rear of the cab
- Optional
- WI-FI Connection optional
- PC Connection input (Optional)
Typical Clinical Use
- Neonatal intensive-care environments
- Newborn and premature infant thermal support
- Hospital neonatal wards and NICU workflows
- Clinical observation, access and care support depending on configuration
Ordering Information
Please contact Nass Ventures to confirm the required configuration, accessories, voltage, installation requirements, training, warranty, delivery and final quotation before ordering.
Important: This neonatal-care product should be selected, configured and used by trained healthcare professionals in appropriate clinical environments and in line with local clinical protocols.
Ertunç Özcan Baby Rest M100 Radiant Heated Open Bed is a neonatal open bed with radiant heating designed to support newborn thermal care workflows.
Product Overview
It has been produced to operate at the highest performance in order to provide the support required for newborn babies to catch the temperature in the mother's womb.
Key Features
- 7-inch TFT screen
- Manual Mode, Skin Mode, Preheating Mode
- Heater Power Value, Set Skin Temperature Value, Timer, Operation Mode parameters can be set as %
- Skin Temperature, Set Skin Temperature, Heating Power Value (in %), Timer, Operating Mode, Trend Graphs with Historical Data can be monitored
- The baby has an X-ray cassette tray under the bed
- It has 4 watt power led inspection lamp, bed tilt feature from -12° to +12° and Apgar timer
Typical Clinical Use
- Neonatal intensive-care environments
- Newborn and premature infant thermal support
- Hospital neonatal wards and NICU workflows
- Clinical observation, access and care support depending on configuration
Ordering Information
Please contact Nass Ventures to confirm the required configuration, accessories, voltage, installation requirements, training, warranty, delivery and final quotation before ordering.
Important: This neonatal-care product should be selected, configured and used by trained healthcare professionals in appropriate clinical environments and in line with local clinical protocols.
Progetti PG NEST Neonatal Incubator on Casters is a neonatal incubator designed to provide a quiet, comfortable and monitored care environment for newborn and premature infants. The PG NEST is listed as a neonatal incubator on casters with height adjustment, Trendelenburg positioning, monitor option, scale option and four operating windows.
Product Overview
The PG NEST incubator uses an air-circuit design intended to reduce outside noise and support a comfortable neonatal environment. The internal temperature is monitored and controlled at multiple points to improve accuracy and safety. The system also monitors air conditions, humidity, oxygen sensor status, airflow probes and fan operation through an alarm system.
Key Features
- Neonatal incubator on casters
- Height-adjustable design
- Trendelenburg positioning
- With monitor option
- With scale option
- Four operating windows
- Quiet air-circuit design to help reduce outside noise
- Internal temperature monitoring and control at multiple points
- Monitoring of air conditions, humidity, oxygen sensor, airflow probes and fan status
- Alarm system listed with 39 different alarms and 16 error messages
- Backup battery support for at least 30 minutes of working conditions
Specifications
- Model: PG NEST
- Brand / manufacturer: Progetti S.r.l.
- Weight: 80 kg(176.4 lb)
- Width: 99.7 cm(39.3 in)
- Height: Min.: 126.1 cm(49.6 in) / Max.: 146.1 cm(57.5 in)
- Main product group: neonatal incubators
Clinical Applications
- Neonatal intensive care
- Newborn and premature infant thermal support
- Hospital neonatal wards and NICU environments
- Clinical monitoring and observation of neonatal environmental conditions
- Critical-care workflows where incubator access, alarms and backup support are required
Ordering Information
Please contact Nass Ventures to confirm the required configuration, monitor and scale options, voltage, accessories, warranty, delivery, training, installation requirements and final quotation before ordering.
Important: This neonatal incubator should be selected, configured and used by trained healthcare professionals in appropriate neonatal-care environments and in line with local clinical protocols.
COMEN B8/B6 Neonatal Incubator is a neonatal incubator model family designed to provide controlled temperature and humidity support for premature infants and critically ill neonates. It is intended for NICU and neonatal-care environments where stable thermoregulation, humidity control, access, monitoring and safe workflow are important.
Product Overview
The B8/B6 neonatal incubator range is designed to create a warm, stable and suitable humidity environment for fragile newborns. The uploaded product page describes the B8 incubator as supporting stable temperature, suitable humidity ambience and configured vital-signs monitoring functions to help care for vulnerable neonatal patients.
Key Features
- Neonatal incubator for premature infants and critically ill neonates
- Designed to provide constant temperature and humidity support
- Intelligent variable-resistance heating technology
- Dual resistive heating tube and fin-style radiator design
- Heating time listed as ≤ 35 minutes for the B8 configuration
- Temperature fluctuation listed as reduced to 0.5 ℃
- Advanced air circulation with symmetrical dual inlet and outlet
- Three independent over-temperature protection systems: system, hardware and mechanical protection
- Humidity control technology using PWM control and an advanced humidity generator
- Effective humidity listed as up to more than 95%
- Titanium alloy evaporation material for corrosion resistance and limescale reduction
- PEEK thermal-isolation material for corrosion, high-temperature and high-pressure resistance
Neonatal Monitoring and Safety Support
- Specialised neonatal monitoring system tailored for NICU use, depending on configuration
- ExNeo® neonatal ECG technology
- Adap-DSP® adaptive NIBP technology
- Masimo SpO₂ support listed on the product page
- Apnea self-rescue monitoring support listed on the product page
- Oxygen-concentration detection function listed on the product page
- Biocompatible specialised neonatal accessories listed as part of the monitoring concept
Workflow and Usability
- Electric lift with pedal and touchscreen dual operation
- Adjustable bed tilt angle with touchscreen control
- Integrated monitor and incubator design
- Easy-to-open damping design on the access panels
- Slow-falling panels designed to reduce noise and support a quiet neonatal environment
- 12.1-inch LED touchscreen
- Backlit keyboard and touch operation
- Adjustable screen angle for easier observation
Available Models
- COMEN B8 Neonatal Incubator
- COMEN B6 Neonatal Incubator
Clinical Applications
- NICU neonatal care
- Premature infant thermoregulation support
- Critically ill newborn care
- Controlled humidity support for low-birth-weight infants
- Neonatal monitoring workflows, depending on configuration
- Daily neonatal nursing and observation
Ordering Information
Please contact Nass Ventures to confirm the required model, monitoring configuration, accessories, voltage, installation requirements, clinical suitability, warranty, delivery, training and final quotation before ordering.
Important: This neonatal incubator should be selected, configured and used by trained healthcare professionals in appropriate neonatal-care environments and in line with local clinical protocols.
COMEN B10 3-in-1 Trinity Incubator is a neonatal care device designed to create a stable and protective microenvironment for preterm and newborn infants. It supports incubator care, radiant warmer workflows and intra-hospital transport support, helping neonatal teams manage temperature stability, access, monitoring and family-centred care.
Product Overview
Preterm infants in the NICU face risks including heat loss, excessive noise and light exposure, infection risk, limited parental contact, complex medical conditions and possible delays in nursing care. The B10 is designed to reduce these risks by supporting a stable, protective and responsive neonatal-care environment.
Key Features
- 3-in-1 neonatal care platform for incubator, warmer and transport-related workflows
- Designed to provide a stable and protective microenvironment for preterm infants
- One-click tilting and 360° rotation for easier positioning and access
- Three-step disassembly to support faster cleaning workflows
- One-click temperature setting to support thermal stability
- Multi-parameter monitoring to provide real-time data for clinical decisions
- Rapid warmth startup and real-time servo temperature control
- Multi-temperature sensor monitoring for responsive temperature adjustment
- High-efficiency, long-lasting humidification performance
- Internal noise management to support restful sleep
- Audio player for music or parent’s voice
- Mood light to support gentle ambience for breastfeeding and bonding
- Koala mode to support skin-to-skin contact and family-centred care
- Integrated multi-controlled mode for controlled temperature management
- Mechanically assisted lift-up canopy for fast transition from incubator mode to radiant warmer mode
Clinical Applications
- NICU neonatal care
- Preterm infant thermoregulation support
- Routine nursing care and monitoring
- Delivery-room immediate newborn care where radiant-warmer use is required
- Intra-hospital newborn transfer from delivery room to NICU
- Emergency-response neonatal care
- Family-centred care and parent-infant interaction
Workflow Benefits
- Supports efficient access to the infant during daily care
- Designed to assist clinicians with stable thermal control and humidity management
- Supports rapid emergency access through canopy lift-up design
- Helps create a more comfortable neonatal environment by managing heat, humidity, sound and light
- Supports bonding activities such as breastfeeding and skin-to-skin care where clinically appropriate
Ordering Information
Please contact Nass Ventures to confirm the required configuration, accessories, voltage, clinical suitability, installation needs, training, warranty, delivery and final quotation before ordering.
Important: This neonatal incubator should be selected, configured and used by trained healthcare professionals in appropriate neonatal-care environments and in line with local clinical protocols.
The BSD EcoLa2000 Infant Incubator is designed to provide a stable, controlled micro‑environment for premature and critically ill newborns. With precise temperature regulation, humidity support and clear access for clinical staff, it supports safe and comfortable neonatal care in hospital nurseries, NICUs and maternity units.
Key Features
- Closed care incubator for infants and premature babies
- Servo‑controlled air and skin temperature monitoring
- Highly visible displays for key parameters
- Access ports and hatches for procedures and interventions
- Integrated safety alarms to alert staff to abnormal conditions
- Ergonomic design for easy cleaning and daily operation
The EcoLa 3000 is a modern neonatal incubator designed to meet the delicate care needs of newborns, offering high-precision control of temperature, humidity and oxygen. An advanced alarm system, PID fuzzy algorithm and ergonomic design help provide a safe, stable and comfortable environment for premature and critically ill babies.
Key Features
- 8.4-inch LCD touchscreen for clear parameter display and easy operation
- Air and skin (body) temperature monitoring with servo control
- O₂ servo control for precise oxygen management
- Humidity monitoring and servo control for optimal micro‑environment
- Trend graphs for 2, 4, 8, 12 and 24 hours to track changes over time
- X‑ray cassette compatibility for imaging without moving the infant
- Integrated weight scale and adjustable height for ergonomic bedside care
- 360° rotating drawers for convenient access to supplies and accessories