BINDER KBF 1600 constant climate chamber
The BINDER KBF 1600 constant climate chamber is specially designed to ensure constant temperature and humidity conditions for demanding stability tests. The pharmaceutical industry and research facilities in particular benefit from its high reliability, as it fulfils critical ICH requirements and can be used for a wide range of long-term tests. Its precise control technology and energy-saving inverter cooling technology make it both efficient and economical, so that this device has established itself as an extremely powerful and durable solution compared to competing products.
Powerful climate simulation for reliable results
This climate chamber impresses with its uniform temperature and humidity distribution throughout the entire interior. The tried-and-tested APT.line preheating chamber technology ensures homogeneous air circulation, which is particularly important in pharmaceutical quality assurance. Thanks to the capacitive humidity sensor and the fast-reacting steam humidification system, humidity control is extremely precise. In addition, the modern inverter chiller significantly reduces energy consumption and increases operational reliability.
The most important technical data at a glance:
- Temperature range: 0 °C to +70 °C (with humidity: 10...70 °C)
- Humidity range: 10...80 % r.H.
- High-quality insulation for low energy consumption
- Inverter cooling technology with R-600a as climate-neutral refrigerant
- Measured values can be read out via internal data logger (USB-Ethernet interfaces)
- Robust double swivel castors with brakes for safe transport
- Touchscreen controller with real-time programming and ergonomic control panel
The appliance has a spacious stainless steel interior with a volume of 1610 litres. The integrated door heater and double-walled housing prevent condensation. The high load capacity of up to 100 kg total load and the two standard shelves make handling heavy samples or appliances effortless. In addition to the powerful cooling system, the rapid recovery time after door openings is also an advantage, as the set conditions are restored within a short time.
The optional light modules are particularly noteworthy. If, for example, ICH photostability tests are required or a plant growth cabinet is needed, the device can be flexibly customised with suitable LED lighting units. This allows the model to cover various research areas without the need to purchase additional specialised units. The intuitive BINDER Multi Management Software APT-COM Basic Edition also makes it easier for users to monitor and document measured values.
Certifications and standards
The construction is designed in accordance with DIN 12880. This standard defines high safety and quality requirements for heating ovens and climate chambers. In addition, the appliance is designed in such a way that essential ICH guidelines regarding temperature and humidity can always be met. This creates the basis for valid data in the development or testing of pharmaceutical products.
Application examples
- Stability testing in the pharmaceutical industry (e.g. for medicines and active ingredients)
- Accelerated shelf life tests in the cosmetics industry (creams, lotions)
- Long-term storage of samples in biotechnology
- Climate simulations in research projects, for example with plant seeds or bacterial cultures
- Material testing in industrial laboratories under constant humidity and temperature conditions
FAQs
How can the device be cleaned
?
The stainless steel interior allows easy decontamination with suitable cleaning agents. Make sure to switch off and cool down the appliance beforehand to avoid damage.
What maintenance intervals are recommended
Seals, sensors and the water supply should be checked at regular intervals. The intervals vary depending on the intensity of use, but can generally be semi-annual or annual.
Is the appliance suitable for continuous operation?
Yes. Thanks to the robust compressor technology and precise control, constant continuous operation for long-term tests is unproblematic. The device's self-check supports reliable operation and indicates potential deviations at an early stage.
Does the model support documentation in accordance with GMP specifications?
The integrated data recording via USB export and the BINDER Multi Management Software APT-COM Basic Edition offer extensive documentation options. This allows GMP requirements to be met efficiently, provided that the laboratory's own validation processes are observed.
Conclusion
The device fulfils the highest requirements for stability tests and climate simulations by providing temperature and humidity reliably and reproducibly. With its energy-efficient inverter cooling technology, robust design and compliance with standards, this constant climate chamber is a future-proof solution for research and development departments in industry and laboratories. Anyone who requires uninterrupted, precise climate management and at the same time values energy efficiency will find a reliable partner in this design.
| Load max.: | 51 - 100 kg |
| Width outside (incubators,...): | 1795 mm |
| Width inside (incubators,...): | 1521 mm |
| Maximum temperature (heat): | + 70 °C |
| Height outside (incubators,...): | 1951 mm |
| Height inside (incubators,...): | 1250 mm |
| Interior volume: | 1501 - 2000 l |
| Maximum power: | 1,7 kW |
| Suitable for: | Pharmaceutical industry |
| Cabinet type: | climate chamberconstant climate chambergrowth chamber |
| Safety standard: | DIN 12880 |
| Depth outside (incubators,...): | 1175 mm |
| Depth inside (incubators,...): | 847 mm |
| Lowest temperature (cooling): | 0 °C |
| Shipping weight: | 438,00 Kg |
| Product weight: | 438,00 Kg |
| Dimensions: | × × cm |