BINDER Walk-in-chamber WIC 2-230V
The BINDER Walk-in-chamber WIC 2-230V is a walk-in climate chamber that was specially developed for precise stability tests in accordance with ICH (Q1A). Thanks to its wide temperature and humidity range, it is ideal for sensitive pharmaceutical applications and quality tests of all kinds. The appliance impresses with its robust design, simple operation and outstanding energy efficiency. Compared to similar solutions, this climate chamber is characterised in particular by its durability, flexible application options and maintenance-friendly design.
Reliable climate and humidity control
This walk-in climate chamber enables a constantly stable environment between 10 °C and 50 °C and 20 % to 90 % relative humidity. Especially in the pharmaceutical industry, these values are crucial to ensure the effectiveness and quality of sensitive products. The stainless steel interior parts minimise corrosion and make cleaning easier. An air guidance system ensures even distribution of the air throughout the entire interior, while highly thermally insulated modules with a U-value of just 0.21 W-m²K guarantee extremely efficient insulation.
The following is a compact overview of the most important key technical data and special features:
- Temperature range: 10...50 °C
- Relative humidity: 20...90 % r.h.
- Maximum temporal temperature deviation of only ±0.5 K
- Maximum temporal humidity deviation of only ±2.5 % r.h.
- Robust and corrosion-resistant interior construction made of stainless steel
- Energy-efficient cooling system with GWP value 547
- Door with generous access and motion sensor LED lighting
The wide interior volume of 18,523 litres and the large interior dimensions (2,400 mm wide, 2,270 mm high, 3,400 mm deep) provide sufficient space for extensive test series. On the outside, the housing is made of galvanised sheet steel (polyester-coated), so that the external climate does not affect the stability of the interior in any way. In addition, the externally accessible service area facilitates maintenance work and enables quick adjustments to be made without interrupting the test room.
Thanks to the certification for stability tests in accordance with the ICH guideline, users in pharmaceutical development, production and quality assurance benefit from a standard-compliant solution. The floor-to-ceiling construction with a ceiling height of 2,470 mm (outside) offers optimum working conditions, while a solid floor support made of chrome-nickel steel supports the loads over a large area.
Certifications and standards
This walk-in chamber fulfils the requirements of ICH (Q1A) and complies with the current standards for temperature and humidity control in laboratory and production environments. It was specially designed for the pharmaceutical industry and can be used in many other areas, such as biotechnology or cosmetics, thanks to its robust and precise design.
Application examples
- Stability and shelf life studies for active pharmaceutical ingredients (e.g. antibiotics, vaccines).
- Long-term storage of temperature-sensitive samples in research laboratories or in-process controls.
- Quality tests for cosmetic products such as creams or lotions that are sensitive to humidity.
- Storage of sensitive substances, such as proteins and enzymes, whose structure only remains stable under controlled climatic conditions.
In addition, the walk-in climate chamber can be used for various research and development tasks where precise control of temperature and humidity is essential.
FAQ
How time-consuming is the maintenance of the walk-in climate chamber?
Maintenance is easy to carry out thanks to the externally accessible service area. This allows routine checks or necessary repairs to be carried out with minimal interruption to the climate control system.
Which certifications are fulfilled
The device is specially designed for stability tests in accordance with ICH (Q1A) and is therefore particularly suitable for use in the pharmaceutical industry. Standards for temperature distribution and humidity accuracy are met.
Is it possible to extend the walk-in chamber?
The modular concept means that small adjustments can be made to the equipment. Different room sizes can be configured with the robust and well-insulating room elements, provided the structural conditions are suitable.
How is the even temperature distribution in the interior ensured?
A specially developed air guidance system ensures constant air circulation and therefore a homogeneous temperature and humidity distribution throughout the test room.
Conclusion
This walk-in climate chamber offers a wide range of applications in stability testing, research and quality control. With its standard-compliant properties, high energy efficiency and particularly user-friendly maintenance, it sets standards for reliable and advanced climate control. It is the ideal solution for ensuring precise results and stable climate conditions in the long term, particularly for sensitive investigations or stability studies in the pharmaceutical and biotechnology sectors.
| Width outside (incubators,...): | 2600 mm |
| Width inside (incubators,...): | 2400 mm |
| Maximum temperature (heat): | + 50 °C |
| Height outside (incubators,...): | 2470 mm |
| Height inside (incubators,...): | 2270 mm |
| Maximum power: | 2.7 kW |
| Cabinet type: | climate chambertest cabinet |
| Depth outside (incubators,...): | 3600 mm |
| Depth inside (incubators,...): | 3400 mm |
| Lowest temperature (cooling): | + 10 °C |
| Shipping weight: | 981,00 Kg |
| Product weight: | 981,00 Kg |
| Dimensions: | × × cm |