OHAUS orbital shaker with incubator for light applications
The OHAUS orbital shaker with incubator for light applications is used for precise and reliable incubation and controlled shaking of samples. The device combines incubator and shaking functions in a compact housing, providing a space-saving solution for laboratories. Thanks to a stable orbital movement and user-friendly digital control, this shaker is ideal for achieving fast and reproducible results in a wide range of applications. Compared to other solutions on the market, the model scores particularly well with its robust die-cast aluminium construction, integrated temperature calibration and flexible range of accessories.
Properties and mode of operation
This device was designed for long-term use in laboratory environments and combines a high load capacity with modern control technology. A brushless DC motor minimises maintenance and noise, while the triple eccentric drive system ensures smooth orbital movement. The enormous versatility is demonstrated, among other things, by the flexible mounting of microplates or module blocks, which allows a wide variety of sample settings.
The temperature range extends from 5 °C above room temperature to 65 °C. Thanks to user-controlled calibration, users can precisely set particularly sensitive temperature profiles. A transparent or opaque lid design enables adaptation to the respective experiment - whether light-protected incubation or direct sample observation. The constant heat distribution ensures reliable results, especially in enzymatic reactions and when cultivating temperature-sensitive organisms.In order to maximise measurement accuracy and user-friendliness, the device has separate LED displays for temperature, speed and time. The latter can be preset between 1 second and up to 160 hours, which also covers longer-term incubations. Integrated overload protection, safe cable routing and a clearly labelled "Caution, hot!" indicator underline the high safety standard.- 3 mm orbital movement, driven by a triple eccentric system
- Available capacity of up to 3.6 kg or four microplates
- Digitally adjustable speed from 100 to 1200 rpm
- Temperature range from ambient +5 °C to 65 °C
- ±0.5 °C uniformity at 37 °C for consistent incubation conditions
- Timer function from 1 second to 160 hours
- Brushless DC motor for low vibration and durability
In addition to these key technical data, the splash-proof design also offers practical safety in everyday laboratory work. The compact dimensions make it easy to set up in confined spaces and the robust aluminium shell is durable enough for regular use.
Certifications and standards
The technical design of the shaker fulfils current safety and quality guidelines. With CE and TÜV approval, the manufacturer documents the guarantee of high standards in terms of safety, electromagnetic compatibility and performance. This makes the device suitable for professional use in modern laboratory and research facilities.
Application examples
The shaker covers a wide range of work steps in biotechnology, pharmaceutical and diagnostics laboratories. Typical applications include:
- Bacteria and yeast cultures: simultaneous incubation and aeration in microplates is easily possible thanks to uniform shaking and stable temperature control.
- Immunoassays (e.g. ELISA assays): Precise adjustment of temperature and stirring speed promotes reproducible reactions and stable test results.
- Cell and tissue cultures: The homogeneous mixing supports cell growth and reduces the risk of sedimentation.
- PCR and enzyme reactions: Error-free temperature control and controlled agitation guarantee optimum conditions for temperature-critical molecular biology processes.
The device can also be customised for light-sensitive or particularly discrete protocols as it can be supplied with differently designed covers. The efficient temperature and shaking control is a decisive advantage for a wide range of samples, from enzyme assays to suspension cultures and hybridisations.
FAQs
How exactly can the temperature be calibrated?
The shaker has a user-defined temperature calibration function that allows users to adjust any deviations. This enables an even more precise setting for particularly sensitive applications.
What is the maximum load capacity?
The device can carry up to 3.6 kg of laboratory vessels or alternatively four microplates or deepwell plates. This means that several samples can be processed at the same time.
What are the advantages of the triple eccentric drive?
This design ensures constant orbital movement and uniform mixing of the solution, which increases the reproducibility and stability of the processes.
Is the shaker loud in operation?
The brushless DC motor usually operates very quietly, making the device suitable for use in sensitive areas. It also requires minimal maintenance.
Can the model be used for longer incubation times?
Yes, thanks to the timer of up to 160 hours, long-term use is also possible. The precise regulation of the temperature provides constantly stable conditions.
Conclusion
This shaker with integrated incubation function is a powerful, reliable solution for laboratories that require reproducible results and versatile application options. The robust design, flexible configuration and precise digital control make the device a sought-after companion for a wide range of processes in the fields of biotechnology, cell research and diagnostics. The combination of efficient temperature stability and safe orbital operation makes it ideal for sensitive reactions as well as routine analyses. With user-friendly operation, a wide range of accessories and comprehensive safety features, the model fulfils advanced laboratory requirements while offering an attractive price-performance ratio.
| External dimensions (W x D x H) (thermal shaker): | 279 x 432 x 197 mm279 x 432 x 270 mm |
| Speed range (thermal shaker): | 100 - 1200 rpm |
| Electrical supply: | 230 V, 50-60 Hz |
| Cooling function: | without |
| Output (thermal shaker): | 450 W |
| Orbit diameter: | 3 mm |
| Shaking movement: | orbital |
| Power connection: | 230 V, 50/60 Hz |
| Temperature max. (thermo shaker): | 65°C |
| Timer: | 1 s - 160 h |
| Suitable for: | PCR plates |