BINDER drying and heating oven M 115-230V
This oven is specially designed for demanding drying and ageing processes in laboratories, research and production. Its robust design combined with precise temperature control up to +300 °C makes it ideal for a wide range of material tests and stability tests. Compared to many conventional heating ovens on the market, the appliance impresses with its particularly even heat distribution, fast heat-up times and sophisticated safety functions in accordance with DIN 12880. Anyone who values first-class process reliability and outstanding temperature accuracy will find this model to be a highly reliable solution.
Properties and technology
This heating oven utilises the innovative APT.line technology, which ensures even temperature distribution in all corners of the interior. This means that even sensitive materials can be reliably dried, cured or stabilised at high temperatures. The integrated touchscreen control enables both time segment and real-time programming, which supports flexible adjustment of the operating parameters to specific applications.
The reinforced fan with adjustable speed is particularly noteworthy. This achieves a high air exchange rate so that the appliance heats up very quickly and quickly returns to the specified temperature after any door openings. Another advantage is the electromechanical control of the exhaust air flap, which can be used to precisely regulate exhaust air volumes. All of this makes the cabinet ideal for intensive laboratory use and for sensitive processes with high temperature stability and consistency requirements.
To ensure maximum safety for users and samples, the appliance has a temperature selector limiter and an additional temperature monitor (class 3.1 in accordance with DIN 12880). An optical and acoustic alarm can be set directly on the controller; there is also a failsafe function with a backup sensor (Pt 100) in case a primary sensor should fail. The Ethernet interface also enables simple integration into laboratory networks and documentation of the measurement data. The integrated data logger saves all relevant values, which can then be conveniently read out via USB.Technical data at a glance
- Temperature range: +23 °C above ambient to +300 °C
- Heating time to 150 °C: 11 minutes
- Recovery time after 30 s door opening at 150 °C: 6 minutes
- Spatial temperature deviation at 150 °C: ±1.0 K
- Temporal temperature deviation at 150 °C: ±0.2 K
- Nominal power: 2.4 kW
- Interior volume: 113 litres
In addition to these core data, the low operating noise of 46 dB(A) is also worth mentioning, which facilitates use in laboratory areas. At 100 °C, an air exchange rate of up to 105 x/h is achieved. Thanks to a maximum load of 150 kg and a load capacity of 30 kg per rack, the appliance is designed for a wide range of sample quantities and weights.
In terms of dimensions, the housing with its compact dimensions (width 710 mm, height 732 mm, depth 636 mm) is space-saving. Two slide-in grilles are also available ex works. If required, up to five shelves are possible to optimally utilise the usable volume.
Standards and certifications
Compliance with DIN 12880 is a key indicator of quality. Both the temperature selector limiter class 2 and the temperature monitor class 3.1 have been tested and certified in accordance with this standard. This proves that the safety systems correspond to the current state of the art and are designed for trouble-free continuous use.
Concrete application examples
- Material testing and ageing tests on plastics or metals to simulate long-term behaviour at high temperatures
- Curing of paints, resins and adhesives in industrial production, where precise temperature control is required
- Drying processes for active pharmaceutical ingredients or chemicals where a constant temperature and controlled air flow are crucial.
- Heat treatment of samples in research laboratories, e.g. for analysing the thermal stability of polymer substances.
FAQs
What is the maximum operating temperature?
Processes up to +300 °C can be realised, allowing a wide range of applications to be served.
How quickly does the appliance reach the target temperature?
Thanks to the reinforced fan and the powerful heating output, heating up to 150 °C only takes around 11 minutes.
When is the temperature stable again after opening the door?
After opening the door for around 30 seconds, the temperature stabilises within the setpoint range again in around 6 minutes.
Is data transmission and recording possible?
Yes, the device can be networked via the Ethernet interface. In addition, all measured values can be transferred via USB in open format.
Conclusion
This heating oven offers an outstanding combination of performance, precision and safety that is impressive in research and industrial environments. Its even heat distribution, fast recovery times and the ability to programme complex temperature profiles make it a versatile laboratory tool. The robust design and extensive safety functions, including additional sensors, ensure trouble-free operation. This makes the processing of temperature-sensitive samples more efficient and safer. Anyone looking for a reliable and high-precision drying solution for laboratories and production will find this device to be a future-proof investment.
| Load max.: | 101 - 150 kg |
| Width outside (incubators,...): | 710 mm |
| Width inside (incubators,...): | 550 mm |
| Maximum temperature (heat): | + 300 °C |
| Height outside (incubators,...): | 732 mm |
| Height inside (incubators,...): | 550 mm |
| Interior volume: | 101 - 200 l |
| Maximum power: | 2,4 kW |
| Cabinet type: | material test chambertest cabinetheating ovenHeating cabinet |
| Safety standard: | DIN 12880 |
| Depth outside (incubators,...): | 636 mm |
| Depth inside (incubators,...): | 375 mm |
| Shipping weight: | 58,00 Kg |
| Product weight: | 58,00 Kg |
| Dimensions: | × × cm |