Amoul AII6000M Plus is a compact emergency and transport ventilator designed for rescue, ambulance, patient transport and urgent respiratory-support workflows. It is lightweight, portable and intended to support quick operation in emergency environments where clinicians need simple controls and fast ventilation setup.
Product Overview
The AII6000M Plus is designed for use with infants, children and adults, depending on the selected settings and clinical protocol. It supports both invasive and non-invasive ventilation and is built around a simple single-knob control concept to make operation easier during rescue and transport situations.
Key Features
- Emergency and transport ventilator for rescue and patient-transfer applications
- Compact and lightweight design, listed by the manufacturer at approximately 0.6 kg
- Easy single-knob operation for fast setup
- Supports invasive and non-invasive ventilation
- Ventilation modes listed by the manufacturer: IPPV, Demand Flow and Manual
- Clear voice-guided direction to support user operation
- One-key switching between invasive and non-invasive ventilation modes
- Suitable for infants, children and adults according to manufacturer information and clinical configuration
- Standard rechargeable battery support
- Optional disposable-battery support
- Designed and tested for rescue/transport environments, including EN 1789 compliance, anti-fall and anti-vibration durability according to manufacturer information
Clinical Applications
- Emergency rescue and pre-hospital care
- Ambulance and transport ventilation
- Inter-hospital and intra-hospital patient transfer
- Emergency departments and resuscitation areas
- Backup ventilation support in clinical transport workflows
Why It Is Useful
The AII6000M Plus is designed for situations where portability, simple operation and fast response are important. Its single-knob interface, voice-guided prompts and compact body make it suitable for ambulance teams, emergency-care providers and hospital transport teams that need a small ventilator for rapid deployment.
Product Details
- Manufacturer / brand: Amoul / Ambulanc (Shenzhen) Tech. Co., Ltd.
- Model: AII6000M Plus
- Product category: Emergency and transport ventilator
- Applications: Rescue and transport
Ordering Information
Please contact Nass Ventures to confirm configuration, battery options, patient circuit requirements, oxygen supply connection, accessories, clinical suitability, warranty, delivery, training and final quotation before ordering.
Important: This is a clinical ventilator and should only be selected, configured and used by trained healthcare professionals in line with local clinical protocols and regulatory requirements.
Amoul T6 is a turbine-driven ICU and transport ventilator designed to support ventilated patients across emergency, critical-care and transport environments. It is built for use in pre-hospital care, intra-hospital transfer, ICU, NICU, operating room, recovery room, general ward and ambulance workflows depending on clinical configuration.
Product Overview
The T6 is an all-in-one ventilator platform intended to accompany the patient through different stages of care. Its turbine-driven design enables high pneumatic performance without reliance on a central gas supply, supporting mobility within and outside the hospital. The system is suitable for adult, paediatric and neonatal patient groups when configured and used according to clinical protocol.
Key Features
- Turbine-driven ICU and transport ventilator
- Designed for emergency, intensive-care and transport ventilation workflows
- All-in-one ventilator concept to accompany the patient throughout the care process
- Minimum tidal volume listed at 2 ml
- Supports adult, paediatric and neonatal patient groups
- Supports invasive and non-invasive ventilation
- Suitable for pre-hospital and intra-hospital transport
- Battery-operated and lightweight for easier movement between care areas
- Can provide pneumatic performance without a central gas supply
- Designed for air, sea and land ambulance environments
- Built for demanding environments including shock, vibration, rain and dust exposure
Ventilation and Clinical Support
- Supports advanced lung-protective ventilation strategies
- Dynamic lung recruitment manoeuvres and P-V tools are listed by the manufacturer
- Designed to support ventilated patient transfer to ICU
- Integrated real-time CPR mode with step-by-step audible and visual prompts
- CPR guidance aligns with AHA and ERC guideline workflows according to manufacturer information
- CPR synchronisation is designed for use with compatible Amoul CPR devices
Mobility and Trolley Configuration
The T6 can be used with a trolley configuration designed to hold and transport the ventilator and accessories, including oxygen cylinders, humidifier, circuit support arm and breathing circuits. This makes it suitable for facilities that need a mobile ventilation platform for emergency care, critical care and transfer workflows.
Typical Applications
- Patient transfer
- ICU and critical-care ventilation
- NICU and neonatal respiratory support when appropriately configured
- Emergency rescue and pre-hospital care
- Ambulance, air ambulance, sea transport and land transport workflows
- Operating room, recovery room and ward-based ventilation support
Ordering Information
Please contact Nass Ventures to confirm the required configuration, patient circuits, trolley options, oxygen cylinder setup, humidifier compatibility, CPR-device integration, warranty, training, delivery and after-sales support before ordering.
Important: This is a clinical ventilator and should only be selected, configured and used by trained healthcare professionals in line with local clinical protocols and regulatory requirements.
Amoul T6 Turbine-Driven ICU & Transport Ventilator
The Amoul T6 is a compact turbine-driven ICU and transport ventilator designed to support ventilated patients across the full care pathway, from emergency response and patient transfer to in-hospital ICU ventilation. It is suitable for adult, paediatric and neonatal patient groups, with a minimum tidal volume of 2 ml and support for both invasive and non-invasive ventilation.
Built for use in demanding clinical and emergency environments, the T6 is battery-operated, lightweight and easy to move between care areas. Its turbine-driven design provides high pneumatic power without relying on a central gas supply, making it suitable for pre-hospital transport, intra-hospital transfer, ICU use, rescue settings and ambulance applications by land, sea or air.
The T6 combines portability, performance and reliability in one all-in-one ventilator platform, helping clinicians maintain respiratory support during critical transfers and emergency care.
Key Features
• Turbine-driven ICU and transport ventilator
• All-in-one ventilator designed to accompany the patient throughout the care process
• Suitable for adults, paediatrics and neonates
• Minimum tidal volume of 2 ml
• Supports invasive and non-invasive ventilation
• Suitable for pre-hospital and intra-hospital transport
• Battery-operated and lightweight for high mobility
• Compact design for easier carrying and movement
• High pneumatic power without the need for a central gas supply
• Rugged and durable design for demanding environments
• Suitable for emergency scenes, ICU use and ambulance transport
• Built to withstand challenging conditions including shock, vibration, rain and dust
• Supports lung-protective ventilation strategies
• Includes advanced tools such as dynamic lung recruitment manoeuvres and P-V tools
• Integrated real-time CPR mode with audible and visual instructions
• Can be used with a trolley to carry ventilator accessories and oxygen cylinders
Product Overview
| Product | Details |
|---|---|
| Model | Amoul T6 |
| Product Type | Turbine-driven ICU and transport ventilator |
| Main Use | Emergency ventilation, ICU ventilation and patient transport |
| Patient Groups | Adult, paediatric and neonatal |
| Minimum Tidal Volume | 2 ml |
| Ventilation Type | Invasive and non-invasive ventilation |
| Drive System | Turbine-driven |
| Gas Supply Requirement | Can provide pneumatic power without central gas supply |
| Power | Battery-operated |
| Main Environments | ICU, emergency rescue, patient transfer and transport |
| Transport Use | Pre-hospital and intra-hospital transport |
| Mobility | Lightweight, compact and trolley-compatible |
Clinical Applications
| Application | Use |
|---|---|
| Patient Transfer | Maintains ventilation support during movement between care areas |
| ICU | Suitable for critical care ventilation support |
| Rescue | Supports emergency response and pre-hospital care |
| Ambulance Transport | Suitable for air, sea and land ambulance applications |
| Emergency Scene | Designed for use at the scene of emergencies |
| In-Hospital Transport | Supports patient transfer to ICU or between hospital departments |
| Non-Invasive Ventilation | Supports patients requiring mask-based ventilation |
| Invasive Ventilation | Supports intubated patients requiring mechanical ventilation |
Ventilation and Performance
| Feature | Benefit |
|---|---|
| Turbine-Driven System | Provides strong pneumatic performance without relying on central gas supply |
| Minimum 2 ml Tidal Volume | Supports ventilation for neonatal and small patient applications |
| Adult, Paediatric and Neonatal Use | Covers a wide range of patient groups |
| Invasive Ventilation | Supports intubated critical care patients |
| Non-Invasive Ventilation | Supports mask-based ventilation workflows |
| Dynamic Lung Recruitment | Supports advanced lung-protective ventilation strategies |
| P-V Tools | Helps clinicians assess respiratory mechanics and guide ventilation strategy |
| ICU and Transport Capability | Allows continuity of ventilation during movement and critical care |
Compact and Mobile Design
The Amoul T6 is designed for high mobility. Its lightweight and compact structure makes it easier to carry and move in and out of hospital environments. The battery-operated design supports transport use, while the turbine-driven system allows the ventilator to operate without depending on a central gas supply.
| Mobility Feature | Advantage |
|---|---|
| Compact Design | Easier to carry, position and store |
| Lightweight Build | Supports rapid movement during emergencies and transfers |
| Battery Operation | Supports use during transport and areas without immediate mains power |
| Trolley Compatibility | Allows transport with accessories, oxygen cylinders, humidifier and breathing circuits |
| Pre-Hospital Use | Suitable for emergency response outside the hospital |
| Intra-Hospital Use | Supports transfer between departments, imaging areas, operating theatres and ICU |
Rugged Design for Demanding Environments
The T6 is built for use across a wide range of environments, from ICU settings to rescue and ambulance transport. According to Amoul, the ventilator is designed for extreme environments including shock, vibration, rain and dust.
| Environment | Suitability |
|---|---|
| ICU | Critical care ventilation support |
| Emergency Scene | Rapid respiratory support during rescue response |
| Ambulance | Land transport ventilation |
| Air Ambulance | Transport ventilation during air transfer |
| Sea Ambulance | Transport ventilation in marine emergency settings |
| Harsh Conditions | Built for shock, vibration, rain and dust exposure |
Integrated Real-Time CPR Mode
The Amoul T6 includes an innovative CPR mode designed to provide clear step-by-step audible and visual instructions for CPR and rescue breathing. The function is designed in line with AHA and ERC guideline-based CPR workflows and can be synchronised with Amoul CPR devices.
| CPR Feature | Benefit |
|---|---|
| Real-Time CPR Mode | Supports guided CPR and rescue breathing |
| Audible Instructions | Helps guide rescuers during emergency response |
| Visual Instructions | Provides clear on-screen support during CPR |
| CPR Device Integration | Can synchronise with Amoul CPR devices |
| Emergency Workflow Support | Helps support structured resuscitation during critical events |
Trolley and Accessory Support
The T6 can be used with a trolley designed to carry the ventilator and essential accessories. This helps create a more complete mobile ventilation solution for transport and emergency use.
| Trolley Support | Details |
|---|---|
| Ventilator Mounting | Designed to hold and transport the ventilator |
| Oxygen Cylinder Support | Can carry oxygen cylinders |
| Humidifier Support | Can accommodate a humidifier |
| Circuit Support Arm | Supports organised breathing circuit management |
| Breathing Circuits | Allows accessories to move together with the ventilator |
| Transport Convenience | Helps create an all-in-one mobile ventilation setup |
Why Choose the Amoul T6?
The Amoul T6 is a strong choice for hospitals, emergency services and critical care teams that need a ventilator capable of working across ICU, transport and rescue environments. Its compact turbine-driven design, battery operation and broad patient compatibility make it suitable for both routine hospital transfer and demanding emergency response.
With support for adult, paediatric and neonatal patients, invasive and non-invasive ventilation, lung-protective strategies and integrated CPR guidance, the T6 offers a practical and reliable solution for facilities that need continuity of respiratory support from the emergency scene to the ICU.
Suitable For
• Intensive care units
• Emergency departments
• Ambulance services
• Patient transfer teams
• Pre-hospital emergency care
• Intra-hospital transport
• Air ambulance services
• Sea ambulance services
• Rescue teams
• Critical care transport units
• Hospitals and specialist medical centres
Ordering Information
Available configurations may vary depending on the selected accessories, trolley setup, oxygen cylinder requirements, humidifier, breathing circuit support and clinical application. Please contact Nass Ventures for pricing, availability, delivery, installation support, training and after-sales service.
Important: Some functions, accessories and trolley configurations may be optional or package-dependent. Please confirm the required ventilation modes, patient group requirements and transport setup before ordering.
- High-Definition Color Touch Screen: Displays parameters and settings clearly.
- User-Friendly Operation: Features automatic positioning and one-key start for simplicity.
- Carbon Dioxide Module: Provides optional real-time CPR quality monitoring.
- Wireless Connectivity: Available as an optional feature for enhanced functionality
- Built-in Dual Battery Design: Ideal for extended rescue operations.
- Charging During Operation: Supports uninterrupted use by allowing charging while in use.
- Compatibility: Simultaneously operates with Amoul® ventilators for enhanced functionality.
- Electrically Controlled: Ensures precise operation
- Adjustable Compression Depth: Allows for customizable settings
- Suction Cup with Repetitive Negative Pressure: Effectively prevents chest cavity collapse
Amoul E8 Cardiopulmonary Resuscitator
The Amoul E8 is a fully electric cardiopulmonary resuscitator designed to deliver mechanical external chest compressions for adult patients suffering from acute cardiac arrest. It is intended to support uninterrupted CPR before hospital admission, within the hospital, and during patient transport.
The E8 is designed to deliver precise 3D compression and includes an external controller monitor for simple, intuitive operation. The controller provides real-time feedback, visible compression depth information and adjustable compression parameters. Data can also be transferred and reviewed on a PC, supporting post-event review, training, quality improvement and clinical documentation workflows.
The E8 is suitable for use in pre-hospital care, emergency departments, intensive care units and transport situations where consistent chest compression support may be required.
Key Features
• Fully electric CPR device
• Designed for mechanical external chest compression
• Suitable for adult patients with acute cardiac arrest
• Precise 3D compression technology
• External controller monitor for simple operation
• Colour screen with real-time feedback
• Visible compression depth information
• Adjustable compression depth and frequency
• Data transfer and PC review support
• USB, Bluetooth and Wi-Fi connectivity for data access
• Mild start function to allow gradual compression start
• Suitable for pre-hospital and intra-hospital use
• Suitable for patient transport during CPR
• Can support extended care pathways such as ECPR transfer, hypothermia management and PCI transfer workflows
• E8 version includes a hand-held terminal
Product Overview
| Product | Details |
|---|---|
| Product Name | Amoul E8 |
| Product Type | Cardiopulmonary resuscitator / CPR system |
| Manufacturer | Ambulanc Shenzhen Tech. Co., Ltd. |
| Model | E8 |
| Main Use | Mechanical external chest compression |
| Intended Patient Group | Adult patients |
| Intended Condition | Acute cardiac arrest |
| Compression Type | 3D compression |
| Control Interface | External controller monitor |
| Data Access | USB, Bluetooth and Wi-Fi |
| Use Environments | Pre-hospital, emergency, ICU, in-hospital and transport |
| E8 / E7 Difference | E8 includes a hand-held terminal; E7 does not |
Intended Use
| Item | Confirmed Detail |
|---|---|
| Intended Use | External chest compression for adult patients suffering from acute cardiac arrest |
| Clinical Situation | Loss of autonomous respiration, pulse beat and consciousness |
| Use Condition | Can be used when external chest compression is helpful for the patient |
| Intended Environment | Before hospital admission, within the hospital and during patient transport |
| Intended Users | Qualified medical personnel trained in CPR system use |
Patient Population
| Patient Requirement | Detail |
|---|---|
| Patient Type | Adult patients |
| Chest Circumference | 70 cm to 150 cm |
| Weight Limitation | Not limited by patient weight, according to the safety/performance document |
| Too Small Patient | Device positioning may fail if the patient is too small |
| Too Large Patient | Device may not lock correctly if the patient is too large |
Applications
| Application Area | Use |
|---|---|
| Pre-Hospital Care | Supports CPR before admission to hospital |
| Emergency Department | Supports CPR workflow in emergency care |
| Intensive Care Unit | Suitable for ICU emergency resuscitation support |
| Patient Transport | Supports CPR during transfer |
| ECPR Pathway | Can support transfer while treating underlying causes during CPR |
| PCI Transfer | Can support ongoing CPR during transfer for coronary intervention pathway |
| Hypothermia Management | Can support extended CPR pathway where clinically required |
External Controller Monitor
| Feature | Benefit |
|---|---|
| Colour Screen | Provides clear operational display |
| Real-Time Feedback | Gives instant updates on CPR performance |
| Visible Compression Depth | Allows staff to monitor compression depth |
| Adjustable Depth | Allows compression depth to be adjusted |
| Adjustable Frequency | Allows compression rate/frequency to be adjusted |
| USB Connectivity | Supports device access and data management |
| Bluetooth / Wi-Fi | Supports wireless data access where configured |
| PC Review | Allows transferred data to be reviewed on a computer |
Compression and Safety Features
| Feature | Description |
|---|---|
| 3D Compression | Combines cardiac and thoracic pump compression principles |
| Mild Start | Provides a gradual start to compression |
| Electrically Controlled Compression | Device adjusts compression depth and mode electrically |
| External Controller | Provides operational control and monitoring |
| Fixing Straps | Used to secure the patient to the CPR system |
| Battery Operation | Device requires battery installed even when powered externally |
| Low Battery Handling | Battery can be replaced or external power connected when low battery occurs |
Data Management
| Function | Details |
|---|---|
| Data Transfer | Device data can be transferred |
| PC Review | Data can be reviewed on a computer |
| USB Access | Supported |
| Bluetooth / Wi-Fi Access | Supported where available/configured |
| Use Case | CPR review, documentation, training and quality improvement |
Important Clinical Notes
| Item | Note |
|---|---|
| Qualified Use Only | The device should only be operated by qualified medical personnel with appropriate training |
| Patient Supervision | The patient must not be left alone while the CPR system is in use |
| Positioning | Correct placement on the patient’s chest is essential |
| Manual CPR Backup | If the device cannot be placed safely and correctly, manual CPR should be performed immediately |
| MRI / Magnetic Environment | The device should not be used in a strong magnetic environment such as MRI |
| High-Pressure Chamber | The device should not be used in high-pressure chamber applications |
| Fire Risk | The device should not be used in oxygen-rich environments or with flammable anaesthetics/reagents |
| Contraindications Listed | Pregnancy, trauma or traumatic cardiac arrest |
| Clinical Responsibility | CPR use and patient treatment remain the responsibility of the clinical team |
Medical Device Classification and Standards
| Item | Detail |
|---|---|
| Medical Device Class | Class IIb according to Regulation 2017/745 |
| EMC Requirement | Meets IEC 60601-1-2 requirements |
| Airborne Equipment Environmental Testing | Meets RTCA DO-160G S20 and S21 |
| Helicopter Use | The safety/performance document states it can be used on helicopters |
Why Choose the Amoul E8?
The Amoul E8 is designed for emergency and critical care teams that require a fully electric mechanical CPR system for consistent external chest compressions during acute cardiac arrest care.
Its 3D compression technology, external controller monitor, real-time feedback, adjustable compression depth and frequency, and data review functions support structured resuscitation workflows. The E8 can be used across pre-hospital care, emergency departments, ICU settings and patient transport, helping clinical teams maintain CPR support during movement and extended emergency care pathways.
Suitable For
• Ambulance services
• Pre-hospital emergency teams
• Emergency departments
• Intensive care units
• Critical care transport teams
• Hospitals
• Resuscitation teams
• Air ambulance and helicopter transport environments, subject to local approval and configuration
• ECPR and PCI transfer pathways, where clinically appropriate
Ordering Information
Available configurations may vary depending on controller, hand-held terminal, connectivity setup, batteries, carrying case, straps, accessories and local regulatory requirements.
Please contact Nass Ventures for pricing, configuration advice, delivery, training and after-sales support.
Important: The Amoul E8 is a professional medical device for trained clinical users only. It should be used strictly according to the manufacturer’s instructions, local resuscitation protocols and clinical judgement. Patient suitability, contraindications, correct positioning and safe operation must be confirmed by the responsible medical team.