BINDER Walk-in-chamber WIC 1-230V
This state-of-the-art climatic chamber is specially tailored to the needs of stability tests in the pharmaceutical industry. In a temperature range of 10 °C to 50 °C and a relative humidity of 20 % to 90 % r.h., reliable test results can be achieved under realistic ambient conditions. Users in research, laboratories and production benefit from a robust, corrosion-resistant design and precise control options. Compared to conventional solutions, the system is characterised by its high energy efficiency and long service life, which not only reduces operating costs but also ensures continuously reliable operation.
Powerful and versatile
This walk-in test room ensures a uniform temperature and humidity distribution that complies with ICH (Q1A) specifications. Thanks to the effective thermal insulation with a U-value of just 0.21 W/m²K, the climate remains stable, even during demanding long-term measurements. A centralised airflow system ensures consistent conditions throughout the interior, enabling reproducible results. Operation is simple and intuitive, allowing specialised personnel to set all parameters effortlessly. In addition, a refrigerant-friendly concept ensures that the environmental impact is minimised.
Key features and technical details
- Temperature range with humidity: 10...50 °C
- Relative humidity: 20...90 % r.H.
- Spatial temperature deviation at 25 °C and 60 % r.h.: ±1.5 K
- Energy consumption at 40 °C and 75 % r.h.: 1,130 Wh/h
- Nominal voltage: 200...230 V (1~), 50 Hz
- Nominal power: 2.7 kW
- Interior volume: 12,530 litres
- Floor delivery in sturdy chrome-nickel steel design
With a temperature deviation of just ±0.5 K over time, the measuring accuracy remains consistently high. Inside, the surface made entirely of stainless steel ensures optimum hygiene and corrosion resistance. The outer cladding is made of galvanised sheet steel with a resistant polyester coating, which means less maintenance and a long service life.
When working with pharmaceutical samples, users benefit from reliable monitoring of all relevant parameters. The humidity accuracy of ±2.5% RH is in the optimum range for monitoring even sensitive products such as tablets, freeze-dried substances or sensitive active ingredients.
Certifications and standards
The device fulfils all the requirements of the European CE marking and is based on the specifications for pharmaceutical quality controls in accordance with ICH Guideline Q1A. This alignment ensures a high level of safety during audits and inspections. The use of state-of-the-art technology, "Made in Germany", emphasises the quality and reliability in daily operation, especially when it comes to regulatory monitored applications.
Practical application examples
- Storage and stability tests of pharmaceutical products (e.g. tablets, capsules, freeze-dried injections)
- Long-term studies with chemicals to investigate product behaviour under various climatic factors
- Monitoring the relative humidity of cosmetic products, such as creams or lotions
- Analyses of packaging materials under variable temperature and humidity conditions
Thanks to its generous internal dimensions (2,400 mm wide, 2,270 mm high, 2,300 mm deep), this chamber is also suitable for larger product batches or bulky test goods.
FAQs
How is the temperature and humidity controlled?
An integrated control system combined with state-of-the-art air routing ensures homogeneous temperature and humidity distribution. Sensors continuously record the actual status and adjust the control accordingly.
How time-consuming is maintenance?
The design allows quick access to all relevant components. Maintenance work can be carried out with minimal interruption to the air conditioning. This includes, for example, the quick replacement of filter units.
Is the appliance suitable for validation?
Yes, thanks to the precise parameter control and documentation options, validations can be carried out without any problems. The standard specifications in accordance with ICH (Q1A) are fully met.
Can several test series be carried out simultaneously?
Due to the generous internal volume and uniform conditions, several test series can easily be carried out side by side without compromising the reliability of the results.
Conclusion
This walk-in climate chamber impresses with its high precision, durability and efficiency. This makes it one of the most reliable systems for stability tests, long-term studies and quality controls in the pharmaceutical industry, as well as in research and development. The ingenious air routing and insulation concept and the robust stainless steel equipment make the system a worthwhile long-term purchase. If you are looking for a powerful and flexible unit for climate testing, this solution offers a good balance between cost efficiency, environmental compatibility and reliable performance. This means that the BINDER walk-in chamber WIC 1-230V can be easily integrated into existing quality management processes and offers optimum conditions for demanding stability tests.
| Width outside (incubators,...): | 2600 mm |
| Width inside (incubators,...): | 2400 mm |
| Maximum temperature (heat): | + 50 °C |
| Height outside (incubators,...): | 2470 mm |
| Height inside (incubators,...): | 2270 mm |
| Maximum power: | 2.7 kW |
| Cabinet type: | climate chambertest cabinet |
| Depth outside (incubators,...): | 2500 mm |
| Depth inside (incubators,...): | 2300 mm |
| Lowest temperature (cooling): | + 10 °C |
| Shipping weight: | 776,00 Kg |
| Product weight: | 776,00 Kg |
| Dimensions: | × × cm |