FASTER SafeFAST Compact microbiological safety cabinet
The FASTER SafeFAST Compact microbiological safety cabinet is a modern Class II solution in accordance with DIN EN 12469, developed for maximum safety and efficiency in microbiological laboratories. Thanks to double-blower technology and sophisticated air routing, it offers reliable personnel protection, product protection and comprehensive contamination control. Compared to comparable systems, this workbench scores points for its quiet operation, flexible options for material composition and energy-saving overall performance.
Modern safety and design features
This safety cabinet is specially designed for working with biological samples, cell cultures and pathogenic microorganisms, while the robust construction and sophisticated functions provide reliable support for the user. The work area is continuously supplied with laminar air flow via two DC blowers, while potentially contaminated air is cleaned via HEPA filters. The latter allow a high retention rate for microorganisms, particles and pathogens. The stainless steel-lined interior design facilitates cleaning and reduces the risk of deposits.
Important safety and convenience aspects result from an intelligent combination of UV LED lights and LED tube lighting. This promotes both disinfection and optimum illumination - especially for delicate manipulations under sterile conditions. In addition, the depth of the outer rear wall adapts to different room conditions, which reduces the noise level and enables back-friendly working.
An overview of the key technical data
- Class: II (in accordance with DIN EN 12469)
- Overall dimensions: approx. 1300 mm width, 2100 mm height, 810 mm depth
- Usable dimensions: approx. 1200 mm width, 670 mm height
- Working opening: 200 mm height
- Lighting: UV LED light for disinfection, LED tube light for uniform illumination
- Material options: Rear panel made of painted steel or optional stainless steel, work surface consistently made of stainless steel
- Gas spring option: front panel opening as with the SafeFAST Elite for easy handling
The double fan structure ensures effective air circulation and provides a constant air flow across the work area. The stainless steel drip tray prevents contamination of the laboratory in the event of accidental liquid spillages. At the same time, the workbench can be optionally equipped with a separate plene, which has its origins in the SafeFAST Premium model range and can guarantee additional efficiency in positive pressure ranges.
Certifications and standards
The device complies with the requirements of DIN EN 12469 for class II microbiological safety cabinets and is manufactured according to strict quality criteria. All critical components are subject to intensive quality control so that the workbench reliably fulfils safety standards in microbiological laboratories.
Concrete application examples
- Sterile work in microbiological laboratories, for example when examining bacteria, fungi and viruses
- Cell culture research and tissue engineering, for example for the cultivation or manipulation of mammalian and mammalian cells
- Quality control in pharmaceutical companies: Sampling, sterile testing and aseptic filling processes
- Microbiological analyses in food production, for example when testing for contamination with salmonella or listeria
Thanks to the sophisticated design and the certified class standard, even the handling of challenging microorganisms or tissue samples is safe. The robust stainless steel finish is also recommended for more intensive cleaning and disinfection cycles.
FAQs
How often should the HEPA filters be changed?
As a rule, we recommend changing the HEPA filters once a year or as specified in the maintenance schedule. A regular airflow test or particle test can provide further information about the condition of the filters.
May the UV LED light remain activated during operation?
For daily disinfection and to protect users, the UV LED lighting should generally be activated before and after work. During operation, personnel are in the work area, which can mean exposure to radiation. Please follow the instructions of the laboratory or manufacturer.
Is the workbench also suitable for working with cytostatics?
For the handling of toxic or cytostatic substances, additional safety requirements are often imposed (e.g. filtering of exhaust air). The device is a Class II safety cabinet, but specific requirements of the respective directives and a suitability assessment from an occupational health perspective should be carried out.
How to set up the silent operation option
The outer rear panel can be mounted in a configuration that minimises the acoustic level. To do this, follow the manufacturer's instructions or seek installation advice.
Conclusion
This versatile safety cabinet combines maximum personnel safety, product protection and process safety in one. It enables safe, low-noise working and can be flexibly adapted to a wide range of laboratory environments. Double blower technology, UV disinfection and high-quality stainless steel surfaces ensure an all-round protected, sterile working area. Together with the robust design and practical equipment options, it offers a reliable solution for demanding microbiological work in laboratories, research facilities and industrial applications.