FASTER SafeFAST Top microbiological safety cabinet with double fan
This safety cabinet is a class II solution for demanding laboratories and cleanrooms that require the highest safety standards. With its robust stainless steel construction, precise air flow and quiet operation, it is often used in microbiological, virological and pharmaceutical applications. The model scores points above all for its reliable combination of personal and product protection and clearly stands out from comparable products thanks to its energy-efficient technology and ergonomic design.
Performance features and special features
The workbench has been specially designed for areas where sensitive or potentially hazardous substances are handled. In addition to the outstanding air purity achieved by a clever combination of main and exhaust air HEPA filters (H14), this model offers numerous features that simplify everyday work in the laboratory:
- Double fan for constant air flow and reliable exhaust air flow
- Energy efficiency with a consumption of less than 281 W for economical operation
- Low noise emissions of maximum 57 dB(A) for a pleasant working environment
- Hinged front window for efficient cleaning of all internal surfaces
- Seamless stainless steel interior with rounded corners for easier decontamination
- Segmented work surface for flexible arrangement of samples and equipment
- Versatile accessories: from IV hanging rods to additional media connections and ergonomic footrests
The entire design enables a uniform vertical air flow, which ensures consistent sterility even with higher sample volumes. In addition, a UV lamp can be integrated for automatic decontamination, which is particularly practical for frequently changing test series or in cleanroom environments.
Technical data at a glance
The device is available in different widths (0.9 m, 1.2 m, 1.5 m and 1.8 m) to fulfil a wide range of requirements. The other dimensions are largely identical, making it easier to integrate into existing laboratory equipment. Key technical specifications include:
- Available sizes (W x H x D): 1015 x 1470 x 785 mm to 1930 x 1470 x 785 mm
- Usable internal dimensions (W x H x D): 885 x 660 x 580 mm to 1800 x 660 x 580 mm
- Inflow: 0.45 m/s, downflow: 0.4 m/s
- Filter: HEPA filter H14 for exhaust air and recirculated air
- Electrical connection: 1Ph+E, 230 V, 50 Hz
- Certified according to: EN 12469 and EN 61010-1
The combination of 70 % recirculated air and 30 % extract air keeps germs and potential contaminants trapped in the area of the filter system. This ensures that both the surrounding laboratory and the samples are effectively protected.
Certifications and standards
Certifications to EN 12469 and EN 61010-1 ensure that the device fulfils all relevant safety standards for Class II workbenches. These stringent tests cover both the safety of personnel and the protection of samples. The model can therefore also be used without any problems in regulated areas with high GMP compliance requirements. It can also be adapted to different international power grids, which facilitates global use in different research and production environments.
Application examples in detail
The flexible configuration and extensive range of accessories make this safety cabinet interesting for a wide variety of applications. Some typical examples:
- Microbiology: The growth and handling of bacterial cultures such as Escherichia coli or Staphylococcus aureus is safe and contamination-free.
- Virology: The examination and preparation of viral samples (e.g. influenza or adenoviruses) are effectively protected by the reliable airflow.
- Cell culture: Sensitive cell lines of animal or human origin can be cultivated under sterile conditions without increasing the risk of contamination.
- Genetics: Genetic engineering processes and extractions of DNA or RNA benefit from the uniform air flow and constant cleanroom level.
In addition, accessories such as vacuum pumps, centrifuges or other laboratory equipment can be connected in the interior. This ensures a consistently sterile environment without the need to relocate reacting samples.
FAQs
How often should the UV lamp be changed?
As a rule, it is advisable to replace the UV lamp every twelve months, as its effectiveness decreases with increasing operating time.
Why is the double fan so important?
Two fan motors ensure a stable air flow in the interior and safe exhaust air handling to the outside. This reliably keeps both germs and impurities at bay.
What is the best way to clean?
The windscreen can be opened by hand so that all surfaces are accessible. A suitable disinfectant can be used to thoroughly clean the seamless stainless steel components in particular.
Can adaptations be made for international power grids?
As the appliance is designed for 1Ph+E - 230 V at 50 Hz as standard, special conversions or additional connections for other power grids can be made on request.
Conclusion
This model offers a convincing overall concept of personal and product protection that fulfils the requirements of laboratories, research institutes and pharmaceutical production in equal measure. A durable design, energy-efficient technology and low-noise operation make it a first-class choice for sensitive processes involving cell cultures, microorganisms and viral samples. Thanks to its flexible sizes, extensive range of accessories and certified conformity with standards (EN 12469, EN 61010-1), it really comes into its own where safety, ergonomics and sustainable application options are crucial. Anyone looking for a reliable and versatile Class II workbench for professional use will find high quality here and benefit in the long term.