comen
COMEN AGSS-H and AGSS-L Anaesthetic Gas Scavenging System
COMEN AGSS-H and AGSS-L anaesthetic gas scavenging systems for compatible hospital exhaust ducts, with model selection based on the stated exhaust-pipe flow rate.
Product introduction
The COMEN AGSS-H and AGSS-L are anaesthetic gas scavenging systems designed to work with hospital anaesthetic gas exhaust pipes. Select the model according to the stated exhaust-pipe flow rate and confirm the duct arrangement and anaesthesia-machine connection before installation.
Key features
Two flow-based models
AGSS-H is specified for exhaust-pipe flow rates above 75 L/min. AGSS-L is specified for rates below 50 L/min.
Duct compatibility
The manufacturer lists jet AGS ducts, negative-pressure AGS ducts and negative-pressure exhaust ducts.
Physical scavenging
The source describes physical gas absorption without a separate gas supply, power supply or chemical consumables.
Machine connection options
The manufacturer describes connection solutions for major anaesthesia-machine brands. Exact model and connector compatibility require confirmation.
Operating principle and waste-gas collection
Waste anaesthetic gas is described as overflow emitted by an anaesthesia machine at the end of expiration. It is discharged intermittently and includes exhaled gas and driving gas. The source identifies N2O, sevoflurane and isoflurane among gases that may be present, and notes waste-gas discharge from semi-closed breathing circuits.
COMEN AGSS works with hospital exhaust pipes to remove anaesthetic waste gases. The manufacturer states that its design helps reduce breathing-circuit ventilation abnormalities associated with negative pressure in exhaust ducts.
The source describes physical gas absorption without a separate gas or power supply and without chemical consumables. A compatible hospital exhaust arrangement is still required.
Model comparison
| Specification | AGSS-H | AGSS-L |
|---|---|---|
| Exhaust-pipe flow rate | > 75 L/min | < 50 L/min |
| Operating method | Physical gas absorption | Physical gas absorption |
| Separate gas or power supply | Not required, according to the supplied source | Not required, according to the supplied source |
| Chemical consumables | Not required, according to the supplied source | Not required, according to the supplied source |
| Installation interface | Compatible hospital anaesthetic gas exhaust pipes | Compatible hospital anaesthetic gas exhaust pipes |
The source does not specify a suitable model for exhaust-pipe flow rates from 50 to 75 L/min, including the stated boundary values. Confirm model selection for that range with the manufacturer.
Compatible ducts and anaesthesia machines
- Jet AGS ducts.
- Negative-pressure AGS ducts.
- Negative-pressure ducts for high- and low-velocity exhaust arrangements.
- Manufacturer-described connection solutions for major anaesthesia-machine brands.
The source claims suitability for almost all anaesthesia machines. Confirm the specific machine, connector and exhaust-system requirements before treating a configuration as compatible.
Commissioning and applications
The manufacturer describes a simple commissioning process and stable exhaust discharge. Installation is intended to work with compatible hospital anaesthetic gas exhaust pipes serving anaesthesia equipment.
Contact Nass Ventures to confirm the exhaust-pipe flow rate, duct type, machine connection and commissioning requirements for the intended installation.
Technical specifications
| Specification | Supplied information |
|---|---|
| Manufacturer | COMEN (Shenzhen Comen Medical Instruments Co., Ltd.) |
| Product type | Anaesthetic gas scavenging system |
| Models | AGSS-H and AGSS-L |
| AGSS-H exhaust-pipe flow | > 75 L/min |
| AGSS-L exhaust-pipe flow | < 50 L/min |
| Operating method | Physical gas absorption |
| Separate gas supply | Not required, according to the supplied source |
| Separate power supply | Not required, according to the supplied source |
| Chemical consumables | Not required, according to the supplied source |
| Exhaust interface | Hospital anaesthetic gas exhaust pipes |
| Duct types listed | Jet AGS, negative-pressure AGS and negative-pressure exhaust ducts |
| Anaesthesia-machine connections | Manufacturer-described solutions for major brands; specific compatibility to be confirmed |
Manufacturer information requiring verification
- Confirm model selection for flow rates of 50–75 L/min, including exactly 50 L/min and 75 L/min. The source supplies no selection rule for these values.
- Confirm the installed duct type, available exhaust flow, operating negative pressure and machine connection requirements.
- Confirm the scope of the statement that no gas or power supply is required, including the hospital exhaust infrastructure needed for operation.
- Confirm the exact anaesthesia-machine models and connectors supported.
The supplied page attributes mutagenicity, carcinogenicity, organ toxicity, fertility effects and psychological effects to inhaled anaesthetics, citing the Chinese Society of Anesthesiology’s “Guidance on the Management of Anesthetic Gas Leaks”. These broad statements are reproduced here as source claims requiring verification against the exact guidance and agent-specific evidence before publication. They are not presented as established effects of every anaesthetic agent.
Dimensions, weight, construction materials, supplied connectors and numerical exhaust performance are not specified in the source.
COMEN AGSS-H and AGSS-L Anaesthetic Gas Scavenging System from Nass Ventures
Contact Nass Ventures for pricing, configuration, compatible accessories, installation requirements and technical support.
COMEN AX-600 Anaesthesia Machine
COMEN AX-600 anaesthesia machine with a 12.1-inch rotating touchscreen, nine ventilation modes, modular AG, EtCO2 and BIS monitoring, and an optional central brake.
Product introduction
The COMEN AX-600 combines ascending bellows ventilation, pneumatic drive and electronic control with a rotating touchscreen and modular monitoring. Its drawer storage and optional central brake support operating-theatre organisation and use.
Key features
Four-way rotating touchscreen
The 12.1-inch touchscreen can be adjusted for clinicians working at different heights and positions.
Perioperative ventilation
Four control modes, three SIMV modes and two pressure support modes are listed.
Modular monitoring
AG, EtCO2 and BIS monitoring functions are described within a flexible, plug-and-play modular design.
Storage and braking
Roomy rotatable and lockable drawer storage is described. A central brake system is optional.
Display and control system
A 12.1-inch four-way rotating touchscreen supports observation and operation from different positions. The source presents this arrangement as accommodating different clinician heights and working preferences.
Perioperative ventilation modes
| Mode group | Number stated |
|---|---|
| Control ventilation | 4 |
| SIMV | 3 |
| Pressure support ventilation | 2 |
The source lists these three groups without identifying every individual mode. They are described for anaesthesia induction, maintenance, recovery and spontaneous breathing practice.
Modular monitoring and configuration
The modular design incorporates anaesthesia-related monitoring functions including AG, EtCO2 and BIS. The source describes plug-and-play operation, flexible configuration and resource sharing. Confirm which modules are included in the quoted configuration and which are optional.
Ventilation technology and breathing circuit
Ascending bellows combine pneumatic drive with electronic control. The manufacturer describes a compact breathing circuit and a smaller loop cavity, with stable ventilation and responsive triggering during SIMV and PSV. It also states a higher compression capacity, without specifying a value or comparison basis.
PEEP supports clinician-directed lung protection and recruitment manoeuvres. The supplied figures are 7% ventilation accuracy and 65 ml/min leakage. These are reproduced as supplied, with no assumed ± tolerance or additional test conditions.
Storage and optional central brake
The manufacturer describes a rotatable and lockable roomy drawer arrangement with extra-large storage for syringes, monitoring accessories and other operating supplies.
The central brake system is optional. It is described as supporting convenient operation and equipment positioning.
Product benefits and applications
- Adjustable touchscreen positioning supports observation and operation from different working positions.
- Modular monitoring allows the configuration to be matched to procurement requirements.
- Drawer storage keeps frequently used supplies within reach.
- Ventilation groups support anaesthesia induction, maintenance, recovery and spontaneous breathing practice.
Technical specifications
| Specification | Supplied information |
|---|---|
| Manufacturer | COMEN (Shenzhen Comen Medical Instruments Co., Ltd.) |
| Model | AX-600 |
| Product type | Anaesthesia machine |
| Display | 12.1-inch touchscreen |
| Display adjustment | Four-way rotation |
| Drive and control | Ascending bellows with pneumatic drive and electronic control |
| Ventilation mode groups | Four control ventilation modes, three SIMV modes and two pressure support ventilation modes |
| Ventilation accuracy | 7%, as stated in the supplied page; tolerance definition not provided |
| Leakage | 65 ml/min, as stated in the supplied page; test conditions not provided |
| PEEP | Supports clinician-directed lung protection and recruitment manoeuvres |
| Autoclavability | Listed as “Autoclavable”; applicable components and validated processing conditions require confirmation |
| Listed monitoring functions | AG, EtCO2 and BIS |
| Modular design | Plug-and-play, flexible configuration and resource sharing |
| Storage | Rotatable and lockable roomy drawer arrangement |
| Central brake system | Optional |
Manufacturer information requiring verification
- Confirm the definition and test conditions of the stated 7% ventilation accuracy. The source does not identify whether this is a ± tolerance.
- Confirm the pressure conditions and measurement method for the stated leakage of 65 ml/min.
- Confirm the full ventilation mode list, available settings and patient-specific operating ranges.
- Confirm which components are autoclavable, together with the validated temperature, cycle and reprocessing instructions.
- Confirm the numerical specification and comparison basis for the stated higher compression capacity.
- Confirm standard and optional monitoring modules, drawer configuration and central brake availability.
Dimensions, weight, power requirements, gas supply requirements and construction materials are not specified in the supplied page.
Product documentation
COMEN AX-600 Anaesthesia Machine from Nass Ventures
Contact Nass Ventures for pricing, configuration, compatible accessories, installation requirements and technical support.
COMEN AX-900 Anaesthesia Workstation
COMEN AX-900 anaesthesia workstation with ascending bellows, electronic fresh-gas control, nine ventilation modes and an independent 8-inch flow-control touchscreen.
Product introduction
The COMEN AX-900 integrates an anaesthesia ventilator, respiratory monitoring functions and electronic fresh-gas control in a surgical workstation. Pneumatic components work with electronic and fluid control to support ventilation, respiratory parameter adjustment and monitoring throughout perioperative use.
Key features
Pneumatic drive and electronic control
Ascending bellows and a compact circuit support ventilation delivery and triggering during SIMV and PSV.
Perioperative ventilation
Four control modes, three SIMV modes and two pressure support modes are listed for different perioperative stages.
Closed-loop fresh-gas control
Direct oxygen-concentration setting with automatic adjustment of the oxygen-to-balance-gas ratio.
Dedicated flow-control display
An independent 8-inch LED touchscreen provides a separate fresh-gas operating area and flow information.
Ventilation technology and breathing circuit
Ascending bellows combine pneumatic drive with electronic control. The manufacturer describes a compact breathing circuit and a smaller loop cavity, with stable ventilation and responsive triggering during SIMV and PSV. It also states a higher compression capacity, without specifying a value or comparison basis.
PEEP supports clinician-directed lung protection and recruitment manoeuvres. The supplied figures are 7% ventilation accuracy and 65 ml/min leakage. These are reproduced as supplied, with no assumed ± tolerance or additional test conditions.
Perioperative ventilation modes
| Mode group | Number stated |
|---|---|
| Control ventilation | 4 |
| SIMV | 3 |
| Pressure support ventilation | 2 |
The source lists these three groups without identifying every individual mode. They are described for anaesthesia induction, maintenance, recovery and spontaneous breathing practice.
Advanced fresh-gas control system
Electronic closed-loop control allows the anaesthetist to set oxygen concentration directly. The system then adjusts the ratio of oxygen to balance gas. Real-time correction of oxygen concentration and total flow is designed to address flow errors associated with fluid inertia.
The Best Flow Indicator Tool displays the flow associated with current anaesthesia ventilation and supports consideration of low-flow anaesthesia. Its colour-spectrum diagram follows the manufacturer’s alarm-colour design to make the current flow value easier to interpret.
Control system and pressure indication
Fresh-gas control uses an independent 8-inch LED touchscreen, providing a separate operating area with detailed flow information. The source does not identify this screen as the main ventilation display.
An electronic gas-source pressure gauge provides pressure indication without a mechanical pointer. The manufacturer describes this as avoiding pointer inertia.
Product benefits and applications
- Separate fresh-gas controls provide a dedicated area for flow adjustment and observation.
- Respiratory monitoring and breathing-parameter adjustment support anaesthesia management during surgical procedures.
- Ventilation groups support induction, maintenance, recovery and spontaneous breathing practice.
- The Best Flow Indicator Tool supports fresh-gas usage assessment during low-flow anaesthesia.
Technical specifications
| Specification | Supplied information |
|---|---|
| Manufacturer | COMEN (Shenzhen Comen Medical Instruments Co., Ltd.) |
| Model | AX-900 |
| Product type | Anaesthesia workstation with integrated ventilator |
| Drive and control | Ascending bellows with pneumatic drive and electronic control |
| Ventilation mode groups | Four control ventilation modes, three SIMV modes and two pressure support ventilation modes |
| Ventilation accuracy | 7%, as stated in the supplied page; tolerance definition not provided |
| Leakage | 65 ml/min, as stated in the supplied page; test conditions not provided |
| PEEP | Supports clinician-directed lung protection and recruitment manoeuvres |
| Autoclavability | Listed as “Autoclavable”; applicable components and validated processing conditions require confirmation |
| Fresh-gas control | Electronic closed-loop control with direct oxygen-concentration setting |
| Automatic adjustment | Oxygen-to-balance-gas ratio, oxygen concentration and total-flow correction |
| Flow indicator | Best Flow Indicator Tool with colour-spectrum display |
| Dedicated flow-control screen | 8-inch LED touchscreen |
| Gas-source pressure indication | Electronic pressure gauge |
| Monitoring | Respiratory monitoring functions and breathing-parameter adjustment |
Manufacturer information requiring verification
- Confirm the definition and test conditions of the stated 7% ventilation accuracy. The source does not identify whether this is a ± tolerance.
- Confirm the pressure conditions and measurement method for the stated leakage of 65 ml/min.
- Confirm the full ventilation mode list, available settings and patient-specific operating ranges.
- Confirm which components are autoclavable, together with the validated temperature, cycle and reprocessing instructions.
- Confirm the numerical specification and comparison basis for the stated higher compression capacity.
- Confirm installed monitoring functions, standard accessories, available options and gas supply requirements.
Dimensions, weight, power requirements, main ventilation display size and construction materials are not specified in the supplied page.
Product documentation
COMEN AX-900 Anaesthesia Workstation from Nass Ventures
Contact Nass Ventures for pricing, configuration, compatible accessories, installation requirements and technical support.
COMEN B10 3-in-1 Trinity Incubator is a neonatal care device designed to create a stable and protective microenvironment for preterm and newborn infants. It supports incubator care, radiant warmer workflows and intra-hospital transport support, helping neonatal teams manage temperature stability, access, monitoring and family-centred care.
Product Overview
Preterm infants in the NICU face risks including heat loss, excessive noise and light exposure, infection risk, limited parental contact, complex medical conditions and possible delays in nursing care. The B10 is designed to reduce these risks by supporting a stable, protective and responsive neonatal-care environment.
Key Features
- 3-in-1 neonatal care platform for incubator, warmer and transport-related workflows
- Designed to provide a stable and protective microenvironment for preterm infants
- One-click tilting and 360° rotation for easier positioning and access
- Three-step disassembly to support faster cleaning workflows
- One-click temperature setting to support thermal stability
- Multi-parameter monitoring to provide real-time data for clinical decisions
- Rapid warmth startup and real-time servo temperature control
- Multi-temperature sensor monitoring for responsive temperature adjustment
- High-efficiency, long-lasting humidification performance
- Internal noise management to support restful sleep
- Audio player for music or parent’s voice
- Mood light to support gentle ambience for breastfeeding and bonding
- Koala mode to support skin-to-skin contact and family-centred care
- Integrated multi-controlled mode for controlled temperature management
- Mechanically assisted lift-up canopy for fast transition from incubator mode to radiant warmer mode
Clinical Applications
- NICU neonatal care
- Preterm infant thermoregulation support
- Routine nursing care and monitoring
- Delivery-room immediate newborn care where radiant-warmer use is required
- Intra-hospital newborn transfer from delivery room to NICU
- Emergency-response neonatal care
- Family-centred care and parent-infant interaction
Workflow Benefits
- Supports efficient access to the infant during daily care
- Designed to assist clinicians with stable thermal control and humidity management
- Supports rapid emergency access through canopy lift-up design
- Helps create a more comfortable neonatal environment by managing heat, humidity, sound and light
- Supports bonding activities such as breastfeeding and skin-to-skin care where clinically appropriate
Ordering Information
Please contact Nass Ventures to confirm the required configuration, accessories, voltage, clinical suitability, installation needs, training, warranty, delivery and final quotation before ordering.
Important: This neonatal incubator should be selected, configured and used by trained healthcare professionals in appropriate neonatal-care environments and in line with local clinical protocols.
COMEN B8/B6 Neonatal Incubator is a neonatal incubator model family designed to provide controlled temperature and humidity support for premature infants and critically ill neonates. It is intended for NICU and neonatal-care environments where stable thermoregulation, humidity control, access, monitoring and safe workflow are important.
Product Overview
The B8/B6 neonatal incubator range is designed to create a warm, stable and suitable humidity environment for fragile newborns. The uploaded product page describes the B8 incubator as supporting stable temperature, suitable humidity ambience and configured vital-signs monitoring functions to help care for vulnerable neonatal patients.
Key Features
- Neonatal incubator for premature infants and critically ill neonates
- Designed to provide constant temperature and humidity support
- Intelligent variable-resistance heating technology
- Dual resistive heating tube and fin-style radiator design
- Heating time listed as ≤ 35 minutes for the B8 configuration
- Temperature fluctuation listed as reduced to 0.5 ℃
- Advanced air circulation with symmetrical dual inlet and outlet
- Three independent over-temperature protection systems: system, hardware and mechanical protection
- Humidity control technology using PWM control and an advanced humidity generator
- Effective humidity listed as up to more than 95%
- Titanium alloy evaporation material for corrosion resistance and limescale reduction
- PEEK thermal-isolation material for corrosion, high-temperature and high-pressure resistance
Neonatal Monitoring and Safety Support
- Specialised neonatal monitoring system tailored for NICU use, depending on configuration
- ExNeo® neonatal ECG technology
- Adap-DSP® adaptive NIBP technology
- Masimo SpO₂ support listed on the product page
- Apnea self-rescue monitoring support listed on the product page
- Oxygen-concentration detection function listed on the product page
- Biocompatible specialised neonatal accessories listed as part of the monitoring concept
Workflow and Usability
- Electric lift with pedal and touchscreen dual operation
- Adjustable bed tilt angle with touchscreen control
- Integrated monitor and incubator design
- Easy-to-open damping design on the access panels
- Slow-falling panels designed to reduce noise and support a quiet neonatal environment
- 12.1-inch LED touchscreen
- Backlit keyboard and touch operation
- Adjustable screen angle for easier observation
Available Models
- COMEN B8 Neonatal Incubator
- COMEN B6 Neonatal Incubator
Clinical Applications
- NICU neonatal care
- Premature infant thermoregulation support
- Critically ill newborn care
- Controlled humidity support for low-birth-weight infants
- Neonatal monitoring workflows, depending on configuration
- Daily neonatal nursing and observation
Ordering Information
Please contact Nass Ventures to confirm the required model, monitoring configuration, accessories, voltage, installation requirements, clinical suitability, warranty, delivery, training and final quotation before ordering.
Important: This neonatal incubator should be selected, configured and used by trained healthcare professionals in appropriate neonatal-care environments and in line with local clinical protocols.
Comen BQ80 Infant Radiant Warmer
The Comen BQ80 is a comprehensive neonatal nursing platform designed to support newborn warming, resuscitation, monitoring and jaundice treatment in one integrated system. Built for delivery rooms, neonatal units, maternity departments and newborn care areas, the BQ80 helps clinical teams provide organised, responsive and efficient care for newborn infants.
The system combines radiant warming, neonatal monitoring, resuscitation support and phototherapy functions into a single care platform. Its design helps reduce the need for multiple separate devices around the infant, supporting faster clinical response and a more streamlined workflow during newborn care and emergency intervention.
The BQ80 includes far infrared ceramic heating technology, a thermal conduction gel mattress, APGAR timer, T-piece resuscitation support, specialised neonatal monitoring, blue-light phototherapy, integrated electronic weighing scale and ergonomic features designed to improve usability for medical staff.
Key Features
• 4-in-1 neonatal nursing platform
• Designed for newborn warming, monitoring, resuscitation and jaundice treatment
• Far infrared ceramic heating tube
• Double heating tube design for faster and more even warming
• High-accuracy dual thermistor temperature sensor
• Thermal conduction gel mattress
• Integrated T-piece resuscitation support
• APGAR score timer
• Specialised neonatal monitoring system
• Masimo SET neonatal blood oxygen technology
• Neonatal ECG and respiration monitoring support
• Adap-DSP blood pressure processing technology
• Patented neonatal apnea self-rescue technology
• Natural blue light phototherapy for jaundice treatment
• CREE high-brightness LED chips
• MIX-light system combining blue and white light
• 10.4-inch colour LCD touchscreen
• Self-adaptive screen brightness adjustment
• Hands-free alarm silence function
• 360° visible alarm indicator
• Built-in X-ray film box
• Integrated electronic scale
• LED puncture lamp with three brightness levels
• Rotary lamp for flexible positioning
• Humanised damping door to reduce noise
• Designed for efficient newborn care and clinical workflow
Product Overview
| Product | Details |
|---|---|
| Product Name | Comen BQ80 |
| Product Number | HCE1180 |
| Manufacturer Code | BQ80 |
| Product Type | Infant radiant warmer / neonatal nursing platform |
| Main Use | Newborn warming, monitoring, resuscitation and jaundice treatment |
| Clinical Areas | Delivery rooms, neonatal units, maternity wards and newborn care areas |
| Platform Type | 4-in-1 neonatal care platform |
| Display | 10.4-inch colour LCD touchscreen |
| Heating Technology | Far infrared ceramic heating tube |
| Mattress Type | Thermal conduction gel mattress |
| Resuscitation Support | Integrated T-piece system |
| Phototherapy | Blue-light phototherapy system |
| Scale | Integrated electronic weighing scale |
| X-ray Support | Built-in X-ray film box |
Clinical Applications
| Application | Use |
|---|---|
| Newborn Warming | Provides radiant heat support for newborn infants |
| Delivery Room Care | Supports immediate newborn care after birth |
| Neonatal Resuscitation | T-piece system supports controlled resuscitation workflow |
| Oxygen Therapy | Supports oxygen therapy through the integrated respiratory support system |
| Sputum Suction | Negative pressure suction support is listed as part of the T-piece system |
| Neonatal Monitoring | Supports monitoring of vital signs and waveforms |
| Jaundice Treatment | Blue-light phototherapy supports neonatal jaundice treatment |
| X-ray Workflow | Built-in X-ray film box allows imaging support without moving the newborn |
| Weight Monitoring | Integrated electronic scale supports newborn weight measurement |
4-in-1 Neonatal Care Platform
The BQ80 is designed to combine four important neonatal care functions in one system. This helps clinical staff manage different stages of newborn care without relying on multiple separate devices.
| Function | Purpose |
|---|---|
| Radiant Warming | Supports newborn thermal care |
| Resuscitation Support | Supports neonatal ventilation, oxygen therapy and suction workflow |
| Neonatal Monitoring | Provides real-time monitoring of vital signs and waveforms |
| Phototherapy | Supports treatment of neonatal jaundice |
Heating and Comfort
The BQ80 uses a far infrared ceramic heating tube system designed to provide consistent warmth for newborn care. The double heating tube design helps distribute warmth across the bed surface, including when the mattress is tilted.
The thermal conduction gel mattress is made from environmentally friendly silicon gel. It is described as soft, comfortable, easy to clean and disinfect, with good thermal performance.
| Heating / Comfort Feature | Benefit |
|---|---|
| Far Infrared Ceramic Heating Tube | Provides radiant warming for newborn thermal care |
| Double Heating Tube Design | Supports faster and more even heat distribution |
| Dual Thermistor Temperature Sensor | Supports more accurate temperature monitoring |
| Thermal Conduction Gel Mattress | Provides a soft and thermally conductive support surface |
| Easy-Clean Mattress Surface | Supports hygiene and routine disinfection |
| Mattress Comfort Design | Helps improve comfort during neonatal care |
Resuscitation and Respiratory Support
The BQ80 includes a T-piece system designed to support newborn resuscitation and respiratory care. It supports ventilation management, negative pressure sputum suction, positive pressure resuscitation and oxygen therapy.
The system is designed to deliver stable and controllable PIP and PEEP, supporting clinical management of functional residual capacity and lung compliance during resuscitation workflow.
| Resuscitation Feature | Function |
|---|---|
| T-piece System | Supports neonatal resuscitation workflow |
| PIP Control | Provides peak inspiratory pressure control |
| PEEP Control | Provides positive end-expiratory pressure support |
| Oxygen Therapy | Supports oxygen delivery during newborn care |
| Negative Pressure Suction | Supports sputum suction workflow |
| Air-Oxygen Mixing | Supports controlled gas mixing where configured |
| APGAR Score Timer | Supports timely newborn assessment |
Neonatal Monitoring System
The BQ80 is described as including a specialised neonatal monitoring system that allows real-time monitoring of vital signs and waveforms during resuscitation, reducing the need for a separate patient monitor in the listed configuration.
| Monitoring Feature | Details |
|---|---|
| Neonatal ECG Technology | ExNeo neonatal ECG technology |
| Blood Pressure Processing | Adap-DSP self-adaptive blood pressure processing |
| Oxygen Saturation Monitoring | Masimo SET neonatal blood oxygen technology |
| Respiration Monitoring | Supports neonatal respiration monitoring |
| Apnea Support | Patented neonatal apnea self-rescue technology |
| Neonatal Accessories | Specialised neonatal accessories included depending on configuration |
| Waveform Display | Waveforms and data displayed on central screen |
Jaundice Treatment
The BQ80 includes blue-light phototherapy for neonatal jaundice treatment. It uses CREE high-brightness LED chips and a MIX-light system that combines blue and white light beams through multiple reflections.
The phototherapy system provides an effective wavelength range of 430–490 nm and light energy up to 45 μW/cm²/nm. A three-position switch allows adjustment between high, medium and low output.
| Phototherapy Feature | Details |
|---|---|
| Light Source | CREE high-brightness LED chips |
| Wavelength Range | 430–490 nm |
| Light Energy | Up to 45 μW/cm²/nm |
| Intensity Levels | High, medium and low |
| MIX-light System | Combines blue and white light beams |
| Light Coverage | Dual lenses support coverage across the bed surface |
| LED Service Life | Over 50,000 hours |
| Timer Display | Displays cumulative and single illumination time periods |
Display and User Interface
The BQ80 features a 10.4-inch colour LCD touchscreen designed to display neonatal waveforms and data centrally. The self-adaptive brightness system adjusts the screen according to ambient light, helping improve visibility and usability in different clinical lighting conditions.
| Interface Feature | Benefit |
|---|---|
| 10.4-inch Colour LCD Touchscreen | Central display for data, waveforms and controls |
| Self-Adaptive Brightness | Automatically adjusts screen brightness according to ambient light |
| Centralised Data Display | Helps staff view key information quickly |
| Hands-Free Alarm Silence | Allows alarm silence by waving a hand in front of the sensor |
| 360° Alarm Indicator | Makes alarms visible from different angles |
| Ergonomic Control Design | Supports simpler operation and workflow efficiency |
Workflow and Ergonomic Design
The BQ80 is designed to simplify operation and improve efficiency in neonatal care. Features such as the hands-free alarm silence, damping door, rotary lamp, built-in X-ray film box and integrated scale help reduce unnecessary handling and support smoother workflow.
| Feature | Workflow Benefit |
|---|---|
| Hands-Free Alarm Silence | Helps silence alarms without touching the unit |
| Humanised Damping Door | Reduces noise and disturbance to the newborn |
| Rotary Lamp | Allows flexible positioning of the heating lamp |
| Built-in X-ray Film Box | Supports X-ray imaging without moving the newborn |
| LED Puncture Lamp | Provides focused lighting for procedures |
| Integrated Electronic Scale | Supports newborn weighing and growth trend recording |
| 360° Alarm Indicator | Improves visibility of alarm events |
| Central Touchscreen | Keeps monitoring data and controls in one place |
X-ray and Procedure Support
The BQ80 includes a built-in X-ray film box located under the crib. This allows imaging support without unnecessary movement of the newborn. The LED puncture lamp provides high-intensity light with three adjustable brightness settings.
| Feature | Details |
|---|---|
| Built-in X-ray Film Box | Located under the crib for imaging support |
| Newborn Handling | Reduces need to move the infant for X-ray workflow |
| LED Puncture Lamp | Provides procedure lighting |
| Puncture Lamp Settings | High, medium and low brightness levels |
| Clinical Benefit | Helps staff observe skin colour and treatment area clearly |
Integrated Electronic Scale
The integrated electronic scale allows newborn weight measurement without needing a separate weighing device. This supports growth monitoring and can help reduce unnecessary disturbance to the infant.
| Feature | Benefit |
|---|---|
| Built-in Electronic Scale | Measures newborn weight on the care platform |
| Growth Monitoring | Helps record and monitor weight trends |
| Reduced Handling | Avoids moving the newborn to a separate scale |
| Clinical Use | Useful for monitoring premature and newborn infants |
Why Choose the Comen BQ80?
The Comen BQ80 is designed for clinical environments that need more than a standard infant warmer. By integrating radiant warming, neonatal monitoring, T-piece resuscitation support and phototherapy into one platform, it helps create a more organised neonatal care workspace.
Its heating system, gel mattress, central touchscreen, integrated monitoring, X-ray film box, electronic scale and ergonomic alarm features make it suitable for departments that require fast response, careful observation and efficient newborn care.
Suitable For
• Delivery rooms
• Neonatal intensive care units
• Newborn care areas
• Maternity hospitals
• Obstetric departments
• Paediatric departments
• Private hospitals
• Specialist neonatal care centres
• Emergency newborn care areas
Ordering Information
Available configurations may vary depending on monitoring package, resuscitation setup, phototherapy configuration, accessories and local supply package.
Please contact Nass Ventures for pricing, delivery, installation support, training and after-sales service.
Important: Some features and accessories may be configuration-dependent. Please confirm the exact specification, included modules, monitoring package, resuscitation system, phototherapy setup, scale and X-ray support before ordering.
COMEN C11 Fetal Monitor
The COMEN C11 Fetal Monitor is a modern CTG fetal monitoring system designed for accurate observation of fetal heart rate, uterine activity, fetal movement, and maternal parameters. It features a large 12-inch high-resolution TFT touchscreen that can be folded up to 90°, allowing clinicians to view and operate the device comfortably from different angles.
The monitor includes an integrated thermal printer, enabling immediate printing of CTG traces and monitoring results for clinical documentation. With its rechargeable lithium-ion battery, the COMEN C11 supports continuous monitoring for approximately 2 to 4 hours, making it suitable for both fixed clinical use and mobile ward applications.
Key Features
Monitors fetal heart rate, TOCO/uterine contractions, fetal movement, and maternal blood pressure where configured
Large foldable 12-inch TFT touchscreen for clear display and easy operation
Integrated printer for instant CTG documentation
Supports ultrasound measurement with a frequency range of 1–3 MHz
Rechargeable lithium-ion battery for flexible clinical use
Provides continuous monitoring for approximately 2 to 4 hours
Supports simultaneous twin fetal monitoring
Compact, portable, and easy to transport
Internal storage capacity for up to 120 hours of CTG recordings
Provides a 96-hour trend graph for clinical review
Automatic evaluation system to support fetal monitoring assessment
Three adjustable alarm levels with visual and audible alerts
USB and Ethernet connectivity for easy data transfer and network integration
Supports both wired and wireless connection options
Product Identification
Manufacturer: COMEN
Manufacturer Article Number: C11
Item Number: 148358
COMEN X8 Anaesthesia Machine
COMEN X8 anaesthesia workstation with electronic fresh-gas control, nine ventilation modes, an 18.5-inch touchscreen, integrated modules and perioperative management tools.
The COMEN X8 brings fresh-gas delivery, ventilation support, monitoring modules and anaesthesia management functions together in an integrated workstation. Its electronic flowmeter and econometer support fresh-gas control and low-flow anaesthesia, while its ventilation modes and lung protection tools support management throughout the perioperative process.
Key features
Electronic fresh-gas control
Directly set FiO2 and total flow using the electronic flowmeter. The econometer provides real-time fresh-gas usage information to guide low-flow anaesthesia and help limit unnecessary anaesthetic agent waste.
Ventilation support
Nine listed modes cover mechanical, adaptive, synchronised and support ventilation: VCV, PCV, PSV/CPAP, SIMV-VC, SIMV-PC, SIMV-PRVC, PRVC, AMV and APRV.
Touchscreen interface
An 18.5-inch capacitive touchscreen displays multiple parameters on one screen. The manufacturer describes 360-degree rotation to accommodate different clinician positions and working preferences.
Perioperative management
High-flow oxygen therapy, lung recruitment tools, respiratory monitoring functions and data interconnection support a continuous perioperative workflow.
Gas delivery and operating principles
The electronic flowmeter allows anaesthetists to set the inspired oxygen fraction (FiO2) and total fresh-gas flow directly. The econometer displays fresh-gas usage information during operation to support low-flow anaesthesia management.
The supplied manufacturer page lists breathing-circuit leakage of 49.5 ml, ventilation deviation of 7% and a sampling-response figure of 1,000 Hz. These figures are reproduced without changing their stated meaning. Their definitions and test conditions require manufacturer confirmation, as detailed below.
Ventilation modes
The manufacturer describes the X8 as providing ICU-level ventilation support for perioperative use, with mechanical, adaptive, synchronised and support ventilation options.
| Function | Manufacturer information |
|---|---|
| Listed ventilation modes | VCV, PCV, PSV/CPAP, SIMV-VC, SIMV-PC, SIMV-PRVC, PRVC, AMV, APRV |
| Adaptive Minute Ventilation (AMV) | Listed as a supported ventilation mode. The explanatory paragraph supplied under this heading requires verification. |
| Airway Pressure Release Ventilation (APRV) | Uses sustained airway pressure with short pressure-release periods. The manufacturer describes this mode in relation to the open-lung principle and preservation of spontaneous breathing. |
Integrated modules and breathing circuit
The manufacturer lists the following modules and systems. Confirm the supplied configuration and module availability when requesting a quotation.
Built-in AGSS
Active anaesthetic waste-gas absorption.
Modular breathing circuit
An integrated modular design supports maintenance and disinfection.
BIS module
Provides an anaesthesia depth indication for intraoperative management.
Negative pressure suction
A dedicated suction system provides airway assistance for anaesthetists.
High-flow oxygen therapy and lung protection tools
The X8 offers continuous high-flow, high-concentration oxygen delivery for perioperative oxygen support. Its lung protection functions provide tools for clinician-directed respiratory management.
- Lung recruitment tools based on the PEEP increment method.
- Oesophageal pressure monitoring.
- Sigh ventilation.
- Inspiratory hold and expiratory hold.
- A VT/IBW tool for ideal tidal volume calculation and guidance on low tidal volume settings.
- Spontaneous breathing modes for use across perioperative stages.
Control system and anaesthesia management
- Soda lime tank in-place reminders support operational checks and management of leakage risks.
- Anaesthesia data review and printing support record archiving and post-case traceability.
- Quick startup and rapid self-tests support preparation for emergency use.
- Visual self-checking procedures guide operators through system checks.
- Gas usage monitoring and anaesthesia consumption warnings support resource management.
Data interconnection and applications
Connection to a data platform through integration equipment supports continuous perioperative data interconnection. The manufacturer describes workflows covering emergency surgery, elective surgery, painless surgery and day surgery.
Confirm the required integration equipment, platform compatibility and local implementation requirements with Nass Ventures before specifying a connected installation.
Technical specifications and product information
| Specification | Supplied information |
|---|---|
| Manufacturer | COMEN (Shenzhen Comen Medical Instruments Co., Ltd.) |
| Model | X8 |
| Product type | Integrated anaesthesia machine |
| Display | 18.5-inch capacitive touchscreen with multi-parameter display |
| Rotation | 360 degrees, as stated by the manufacturer |
| Fresh-gas control | Electronic flowmeter with direct FiO2 and total-flow setting |
| Fresh-gas usage guidance | Real-time econometer |
| Breathing-circuit leakage | 49.5 ml, as supplied; measurement conditions not stated |
| Ventilation deviation | 7%, as supplied; tolerance definition not stated |
| Sampling response | 1,000 Hz, as supplied; measurement definition not stated |
| Ventilation modes | VCV, PCV, PSV/CPAP, SIMV-VC, SIMV-PC, SIMV-PRVC, PRVC, AMV, APRV |
| Listed modules and systems | Built-in AGSS, modular breathing circuit, BIS module and negative pressure suction system |
| Oxygen therapy | Continuous high-flow, high-concentration oxygen delivery |
| Lung recruitment method | PEEP increment method |
| Additional respiratory tools | Oesophageal pressure monitoring, sigh ventilation, inspiratory hold, expiratory hold and VT/IBW tool |
| Data functions | Data review, printing and platform interconnection through integration equipment |
| Operational checks | Soda lime tank reminders, rapid self-tests, visual self-checking and consumption warnings |
Manufacturer information requiring verification
- Confirm the leakage measurement basis for 49.5 ml, including any applicable time interval and pressure conditions.
- Confirm the definition and test conditions for 7% ventilation deviation and the meaning of the 1,000 Hz sampling-response figure.
- Confirm which assembly provides the stated 360-degree rotation.
- The supplied AMV section contains an apparently unrelated control-system paragraph. It reads: “The override control panel and hand remote are on standby. The override control panel enables all movements in case of hand remote failure. The wall panel and remote control are optional.” This wording requires manufacturer verification and is not presented here as a confirmed X8 control-system specification.
- Confirm standard and optional modules, accessories and integration equipment for the selected configuration.
Dimensions, weight, power requirements, gas supply requirements and construction materials are not specified in the supplied product page.
Product documentation
Manufacturer product safety and performance information for the X5/X6/X7/X8 family
COMEN X8 from Nass Ventures
The X8 combines fresh-gas control, ventilation modes, an integrated touchscreen interface and perioperative management functions in one anaesthesia workstation.
Contact Nass Ventures for pricing, configuration, compatible accessories, installation requirements and technical support.