FASTER safety cabinet SafeFAST Classic double blowerFASTER safety cabinet SafeFAST Classic double blower is a Class II microbiological safety cabinet, and belongs to the latest generation of vertical laminar flow systems. Even the strictest safety standards are guaranteed by selecting construction materials of the highest quality. This benefits both people and the environment.
FASTER SafeFAST Classic twin blowers meet the requirements of EN-12469: 2000, with 70% recirculating air through the main HEPA Class H14 filter and 30% continuing through a Class H14 HEPA exhaust filter. Safety cabinets with automatic control and microprocessor-based recording system. Benches in this series are suitable for handling microorganisms and pathogens as defined in relevant European and other international standards. Furthermore, they comply with all applicable health and safety guidelines for the protection of persons working on this equipment. FASTER SafeFAST Classic twin blowers are equipped with a centrifugal blower. For the best protection of the entire environment.
Respect for our environment motivates FASTER to manufacture laminar flow, cytostatic and microbiological safety workbenches that have minimal impact. Specifically, we achieve this through the use of:
- Certified HEPA filters with low pressure drop, which accounts for energy savings of up to 30%.
- Electronically controlled fan motors with automatic pressure drop compensation
- 99% recyclable components
- Innovative technologies such as the new ECS microprocessor
The new ECS microprocessor controls the complete recording:
The user can call up the status report of the workbench at any time via the two-line digital display of the new processor generation. All functions and safety alarm systems are monitored seamlessly and fully automatically in accordance with the EN12469: 2000 standard. A high-performance lithium battery ensures the storage of safety data in the microprocessor. The user-friendly keyboard and the backlit LCD display continuously show the user all the necessary data, in detail:
- Display of the laminar flow speed and the face velocity at the front.
- Display of the indoor and outdoor temperature
- Display of remaining filter runtime and UV lamp (if present)
- Display of the total operating hours
- Display of the filter contamination level
Audible/visual alarms for:
- Laminar flow out of bandwidth or incorrect laminar flow velocity and inflow velocity at the front
- incorrect position of the front pane
- Degree of contamination of the HEPA filters
- End of life cycle of the UV lamp (if present)
- Blockage in the exhaust air connection
- Malfunction of the fan motor
- Power failure
Certification: ISO 9001 certified
Equipment at a glance:
- Motorised windscreen
- 1 socket at 0.9 m and 1.2 m
- 2 sockets at 1.5 and 1.8 m
- Media connections per side pane 3 pcs.
- Operating mode for night setback
- Antibacterial coating
- Low noise level
- Stainless steel 1.4404 (AISI 316L)
- True laminar flow
Attention: Please specify media connections when ordering, retrofitting is not possible.