BioSan UVC/T-AR PCR cabinet
The BioSan UVC/T-AR PCR cabinet is a state-of-the-art solution for laboratories that require a reliable, contamination-free environment for PCR setups and other sensitive nucleic acid applications. Thanks to dual UV sterilisation and an integrated recirculation fan, the device impresses with its efficient decontamination and simultaneous safety compared to many commercially available alternatives. Specially developed for use in areas where the highest cleanliness standards are required, this workstation offers an indispensable advantage in laboratory practice.
Powerful features and technologies
The construction is based on a robust metal plate with chemical-resistant powder coating and UV-resistant Plexiglas walls, which ensures long-term durability. The generous work surface of 645 x 490 mm provides enough space to handle sensitive samples and position equipment safely. Thanks to the excellent optical transmission (92%), users always have an overview of their ongoing processes.
The following core functions and benefits are particularly noteworthy:
- Dual UV lamp technology for maximum sterilisation performance:
- An open 25 W UV-C lamp (254 nm, ozone-free) reliably inactivates DNA, RNA, viruses and bacteria in a short time.
- A patented UV recirculator flows through the entire interior at around 20 m³/h and continuously keeps the air clean.
- Intuitive touchscreen control:
- Digital 3.5-inch screen that can also be operated with gloves on.
- Programmable timer function (1 minute to 24 hours) for UV exposure.
- Real-time monitoring of lamp life and maintenance intervals.
- Effective protection for users:
- Automatic switch-off of the open UV lamp when the front screen is open.
- Plexiglas shields with over 99.9 % UV protection reduce any health risks.
- Air circulation fan prevents direct UV radiation towards the user.
- Ergonomic details:
- Flame-retardant, durable side walls with 4 mm thickness and 8 mm thick upper front wall for additional stability.
- An integrated LED lighting system (8 W) ensures bright illumination and saves around 50% energy compared to conventional lamps.
- Low noise level thanks to quiet fan technology.
Certifications and standards
The equipment fulfils relevant European safety requirements and is CE-compliant. The materials and electrical components comply with current laboratory standards, ensuring safe operation for users. Polymethyl methacrylate in the walls guarantees a very high level of UV protection and prevents damage from UV radiation. The relevant safety functions include the automatic switch-off of the open UV lamp, which makes work much easier and provides additional protection.
Examples of use
- PCR setup in molecular biology: Ideal for the precise creation of PCR reaction preparations without cross-contamination from aerosols or nucleic acid residues.
- Amplification and purification of DNA/RNA: When working with sensitive nucleic acids such as plasmids, viral RNA segments or genome DNA, the permanent decontamination ensures reliable results.
- Cloning processes and transformations in microbial systems: The cabinet design minimises the risk of foreign germs, which is crucial in bacterial or fungal-based processes.
- Sensitive sample preparation: Samples can also be processed without risk of contamination in medical diagnostics or forensics, for example when preparing samples with reagents, enzymes (such as Taq polymerase) and dyes.
FAQs
How long should UV decontamination take?
The duration can be programmed between a few minutes and up to 24 hours. Typically, 15-30 minutes of open UV radiation is sufficient to inactivate common germs and nucleic acids.
Can other devices be used inside during operation?
Yes, it is possible to operate smaller laboratory instruments such as pipette stands or mini centrifuges without affecting the sterilisation process thanks to the existing cable feed-throughs.
Is there a risk to operating personnel from UV radiation?
No, because both the Plexiglas walls provide over 99.9 % protection and the automatic switch-off system for the open UV lamp prevents accidental exposure. In addition, the integrated air circulation fan ensures that the germicidal radiation is concentrated in the internal circulation system and does not escape to the outside.
How often should the UV lamps be replaced?
The integrated lamps have an average service life of around 9,000 operating hours. The device monitors the usage time using the digital display and informs you as soon as it makes sense to replace the lamps.
Conclusion
The oven presented here combines outstanding sterilisation efficiency with first-class safety features, making it an ideal choice for laboratories that strive for absolute freedom from contamination. Convenient touchscreen control, automated maintenance and safety functions and robust, durable construction make it a valuable tool in the modern laboratory. Every step, from sample preparation to subsequent analysis, is supported by reliable UV protection without compromising productivity. In this way, scientific institutions and research laboratories benefit from cleaner, safer workflows and more precise results.
| Areas of application: | LaboratoriesAnalytical chemistryBiotechnologyPharmaceutical industry |
| Width: | 701 mm - 800 mm |
| Device type: | PCR box |
| Height: | 501 mm - 600 mm |
| Depth: | 501 mm - 600 mm |
| Shipping weight: | 30,00 Kg |
| Product weight: | 21,40 Kg |
| Dimensions: | × × cm |